These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Failure of selective shunting to intercostal arteries to prevent spinal cord ischemia during experimental thoracoabdominal aortic occlusion. Lowell RC; Gloviczki P; Bergman RT; Stanson AW; Dzsinich C; Bower TC; Cherry KJ Int Angiol; 1992; 11(4):281-8. PubMed ID: 1295934 [TBL] [Abstract][Full Text] [Related]
3. Cold spinoplegia and transvertebral cooling pad reduce spinal cord injury during thoracoabdominal aortic surgery. Isaka M; Kumagai H; Sugawara Y; Okada K; Orihashi K; Ohtaki M; Sueda T J Vasc Surg; 2006 Jun; 43(6):1257-62. PubMed ID: 16765250 [TBL] [Abstract][Full Text] [Related]
4. The reliability of evoked spinal cord potentials elicited by direct stimulation of the cord as a monitor of spinal cord ischemia during temporary occlusion of the thoracic aorta. Matsui Y; Shiiya N; Ishii K; Murashita T; Sasaki S; Sakuma M; Yasuda K Panminerva Med; 1997 Jun; 39(2):78-84. PubMed ID: 9230615 [TBL] [Abstract][Full Text] [Related]
6. Evoked potentials: ten-year experience with a valuable research and clinical tool. Marini CP; Cunningham JN Semin Thorac Cardiovasc Surg; 1991 Oct; 3(4):286-92. PubMed ID: 1793765 [No Abstract] [Full Text] [Related]
7. Direct noninvasive monitoring of spinal cord motor function during thoracic aortic occlusion: use of motor evoked potentials. Laschinger JC; Owen J; Rosenbloom M; Cox JL; Kouchoukos NT J Vasc Surg; 1988 Jan; 7(1):161-71. PubMed ID: 3336122 [TBL] [Abstract][Full Text] [Related]
8. Spinal cord protection during surgical procedures on the descending thoracic and thoracoabdominal aorta: review of current techniques. Gharagozloo F; Larson J; Dausmann MJ; Neville RF; Gomes MN Chest; 1996 Mar; 109(3):799-809. PubMed ID: 8617093 [No Abstract] [Full Text] [Related]
9. New surgical techniques for the prevention of paraplegia during aortic surgery. Wadouh F Thorac Cardiovasc Surg; 1992 Feb; 40(1):26-32. PubMed ID: 1631862 [TBL] [Abstract][Full Text] [Related]
10. Novel approaches to spinal cord protection during thoracoabdominal aortic interventions. Augoustides JG; Stone ME; Drenger B Curr Opin Anaesthesiol; 2014 Feb; 27(1):98-105. PubMed ID: 24322209 [TBL] [Abstract][Full Text] [Related]
11. Near-infrared spectroscopy monitoring of the collateral network prior to, during, and after thoracoabdominal aortic repair: a pilot study. Etz CD; von Aspern K; Gudehus S; Luehr M; Girrbach FF; Ender J; Borger M; Mohr FW Eur J Vasc Endovasc Surg; 2013 Dec; 46(6):651-6. PubMed ID: 24099957 [TBL] [Abstract][Full Text] [Related]
12. [Effect of regional hypothermia on cerebrospinal fluid parameters during thoracoabdominal aorta clamping in dogs]. Dzsinich C; Nagy G; Selmeci L; Sepa G; Fazekas L; Kékesi V; Juhász-Nagy S Magy Seb; 2000 Apr; 53(2):79-84. PubMed ID: 11299626 [TBL] [Abstract][Full Text] [Related]
13. Is paraplegia after repair of coarctation of the aorta due principally to distal hypotension during aortic cross-clamping? Krieger KH; Spencer FC Surgery; 1985 Jan; 97(1):2-7. PubMed ID: 3966226 [TBL] [Abstract][Full Text] [Related]
14. Intrathecal papaverine for the prevention of paraplegia after operation on the thoracic or thoracoabdominal aorta. Svensson LG; Stewart RW; Cosgrove DM; Lytle BW; Antunes MD; Beven EG; Furlan AJ; Gottlieb A; Grum DF; Hinder RA J Thorac Cardiovasc Surg; 1988 Nov; 96(5):823-9. PubMed ID: 3054343 [TBL] [Abstract][Full Text] [Related]
15. [Protection against spinal cord ischemia in the treatment of traumatic rupture of the aortic isthmus]. Donzeau-Gouge GP; Bical O; Blondeau P; Piwnica A; Carpentier A; d'Allaines C; Nottin R; Massoud H; Benómar M; Chauvaud S Ann Chir; 1983 Mar; 37(2):137-9. PubMed ID: 6680810 [No Abstract] [Full Text] [Related]
16. Spinal cord ischemic injury: is it preventable? Kouchoukos NT Semin Thorac Cardiovasc Surg; 1991 Oct; 3(4):323-8. PubMed ID: 1793768 [No Abstract] [Full Text] [Related]
17. Avoidance of renal and neurologic complications following thoracoabdominal aortic aneurysm repair. Hollier LH; Moore WM Acta Chir Scand Suppl; 1990; 555():129-35. PubMed ID: 2368560 [No Abstract] [Full Text] [Related]
18. Ischaemic injury to the spinal cord as a complication to abdominal aortic surgery. Paaschburg Nielsen B Acta Chir Scand; 1985; 151(5):433-5. PubMed ID: 4050273 [TBL] [Abstract][Full Text] [Related]
19. Electrophysiologic monitoring during surgery to repair the thoraco-abdominal aorta. Sloan TB; Jameson LC J Clin Neurophysiol; 2007 Aug; 24(4):316-27. PubMed ID: 17938600 [TBL] [Abstract][Full Text] [Related]
20. Adequacy of ascending aorta-descending aorta shunt during cross-clamping of the thoracic aorta for prevention of spinal cord injury. Molina JE; Cogordan J; Einzig S; Bianco RW; Rasmussen T; Clack RM; Borgwardt B J Thorac Cardiovasc Surg; 1985 Jul; 90(1):126-36. PubMed ID: 4010314 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]