These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 8252968)

  • 1. Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier.
    Branson RD; Davis K; Campbell RS; Johnson DJ; Porembka DT
    Chest; 1993 Dec; 104(6):1800-5. PubMed ID: 8252968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients.
    Kollef MH; Shapiro SD; Boyd V; Silver P; Von Harz B; Trovillion E; Prentice D
    Chest; 1998 Mar; 113(3):759-67. PubMed ID: 9515854
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia.
    Thomachot L; Viviand X; Arnaud S; Boisson C; Martin CD
    Chest; 1998 Nov; 114(5):1383-9. PubMed ID: 9824019
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
    Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days.
    Thomachot L; Leone M; Razzouk K; Antonini F; Vialet R; Martin C
    Crit Care Med; 2002 Jan; 30(1):232-7. PubMed ID: 11902268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia.
    Davis K; Evans SL; Campbell RS; Johannigman JA; Luchette FA; Porembka DT; Branson RD
    Crit Care Med; 2000 May; 28(5):1412-8. PubMed ID: 10834688
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min.
    Martin C; Papazian L; Perrin G; Bantz P; Gouin F
    Chest; 1992 Nov; 102(5):1347-50. PubMed ID: 1424849
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation. A prospective randomized study.
    Misset B; Escudier B; Rivara D; Leclercq B; Nitenberg G
    Chest; 1991 Jul; 100(1):160-3. PubMed ID: 2060336
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Active humidification in mechanical ventilation is not associated to an increase in respiratory infectious complications in a quasi-experimental pre-post intervention study.
    Picazo L; Gracia Arnillas MP; Muñoz-Bermúdez R; Durán X; Álvarez Lerma F; Masclans JR
    Med Intensiva (Engl Ed); 2021; 45(6):354-361. PubMed ID: 34294233
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion.
    Kirton OC; DeHaven B; Morgan J; Morejon O; Civetta J
    Chest; 1997 Oct; 112(4):1055-9. PubMed ID: 9377917
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical outcome associated with the use of different inhalation method with and without humidification in asthmatic mechanically ventilated patients.
    Moustafa IOF; ElHansy MHE; Al Hallag M; Fink JB; Dailey P; Rabea H; Abdelrahim MEA
    Pulm Pharmacol Ther; 2017 Aug; 45():40-46. PubMed ID: 28435031
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill.
    Ricard JD; Markowicz P; Djedaini K; Mier L; Coste F; Dreyfuss D
    Chest; 1999 Jun; 115(6):1646-52. PubMed ID: 10378563
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Resistive pressure of a condenser humidifier in mechanically ventilated patients.
    Manthous CA; Schmidt GA
    Crit Care Med; 1994 Nov; 22(11):1792-5. PubMed ID: 7956283
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of Airway Humidification Strategy in Mechanically Ventilated COVID-19 Patients.
    Lavoie-Bérard CA; Lefebvre JC; Bouchard PA; Simon M; Lellouche F
    Respir Care; 2022 Feb; 67(2):157-166. PubMed ID: 34670857
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
    Thomachot L; Vialet R; Arnaud S; Barberon B; Michel-Nguyen A; Martin C
    Crit Care Med; 1999 May; 27(5):923-8. PubMed ID: 10362414
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
    Martin C; Papazian L; Perrin G; Saux P; Gouin F
    Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Humidification and secretion volume in mechanically ventilated patients.
    Solomita M; Palmer LB; Daroowalla F; Liu J; Miller D; LeBlanc DS; Smaldone GC
    Respir Care; 2009 Oct; 54(10):1329-35. PubMed ID: 19796412
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Airway humidification in mechanically ventilated neonates and infants: a comparative study of a heat and moisture exchanger vs. a heated humidifier using a new fast-response capacitive humidity sensor.
    Schiffmann H; Rathgeber J; Singer D; Harms K; Bolli A; Züchner K
    Crit Care Med; 1997 Oct; 25(10):1755-60. PubMed ID: 9377894
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Hygroscopic Condenser Humidifier. A new device for general use in anaesthesia and intensive care.
    Gedeon A; Mebius C
    Anaesthesia; 1979; 34(10):1043-7. PubMed ID: 539642
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.