BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 8256902)

  • 21. Aerosol delivery from a metered-dose inhaler during mechanical ventilation. An in vitro model.
    Fink JB; Dhand R; Duarte AG; Jenne JW; Tobin MJ
    Am J Respir Crit Care Med; 1996 Aug; 154(2 Pt 1):382-7. PubMed ID: 8756810
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Randomized controlled trial of salbutamol aerosol therapy via metered dose inhaler-spacer vs. jet nebulizer in young children with wheezing.
    Deerojanawong J; Manuyakorn W; Prapphal N; Harnruthakorn C; Sritippayawan S; Samransamruajkit R
    Pediatr Pulmonol; 2005 May; 39(5):466-72. PubMed ID: 15786440
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Bronchodilator delivered by metered dose inhaler and spacer improves respiratory system compliance more than nebulizer-delivered bronchodilator in ventilated premature infants.
    Sivakumar D; Bosque E; Goldman SL
    Pediatr Pulmonol; 1999 Mar; 27(3):208-12. PubMed ID: 10213261
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Efficacy of metered-dose inhaler administration of albuterol in intubated infants.
    Torres A; Anders M; Anderson P; Heulitt MJ
    Chest; 1997 Aug; 112(2):484-90. PubMed ID: 9266888
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Albuterol delivery in a model of mechanical ventilation. Comparison of metered-dose inhaler and nebulizer efficiency.
    Diot P; Morra L; Smaldone GC
    Am J Respir Crit Care Med; 1995 Oct; 152(4 Pt 1):1391-4. PubMed ID: 7551401
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Efficiency of aerosol medication delivery from a metered dose inhaler versus jet nebulizer in infants with bronchopulmonary dysplasia.
    Fok TF; Monkman S; Dolovich M; Gray S; Coates G; Paes B; Rashid F; Newhouse M; Kirpalani H
    Pediatr Pulmonol; 1996 May; 21(5):301-9. PubMed ID: 8726155
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluating the length of stay and value of time in a pediatric emergency department with two models by comparing two different albuterol delivery systems.
    Staggs L; Peek M; Southard G; Gracely E; Baxendale S; Cross KP; Kim IK
    J Med Econ; 2012; 15(4):704-11. PubMed ID: 22400716
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Albuterol delivery by metered-dose inhaler with a pediatric mechanical ventilatory circuit model.
    Garner SS; Wiest DB; Bradley JW
    Pharmacotherapy; 1994; 14(2):210-4. PubMed ID: 8197041
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Inhaled fenoterol-ipratropium bromide in mechanically ventilated patients with chronic obstructive pulmonary disease.
    Guerin C; Chevre A; Dessirier P; Poncet T; Becquemin MH; Dequin PF; Le Guellec C; Jacques D; Fournier G
    Am J Respir Crit Care Med; 1999 Apr; 159(4 Pt 1):1036-42. PubMed ID: 10194143
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Determinants of aerosolized albuterol delivery to mechanically ventilated infants.
    Coleman DM; Kelly HW; McWilliams BC
    Chest; 1996 Jun; 109(6):1607-13. PubMed ID: 8769518
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluating the delivery of nebulized and metered-dose inhalers in an in vitro infant ventilator lung model.
    Avent ML; Gal P; Ransom JL; Brown YL; Hansen CJ; Ricketts WA; Soza F
    Ann Pharmacother; 1999 Feb; 33(2):144-8. PubMed ID: 10084407
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of inspiratory flow rate on beta2-agonist induced bronchodilation in mechanically ventilated COPD patients.
    Mouloudi E; Prinianakis G; Kondili E; Georgopoulos D
    Intensive Care Med; 2001 Jan; 27(1):42-6. PubMed ID: 11280671
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Albuterol delivery by metered-dose inhaler in a mechanically ventilated pediatric lung model.
    Garner SS; Wiest DB; Bradley JW; Lesher BA; Habib DM
    Crit Care Med; 1996 May; 24(5):870-4. PubMed ID: 8706467
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Automatic replacement of albuterol nebulizer therapy by metered-dose inhaler and valved holding chamber.
    Hendeles L; Hatton RC; Coons TJ; Carlson L
    Am J Health Syst Pharm; 2005 May; 62(10):1053-61. PubMed ID: 15901590
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Albuterol delivery during noninvasive ventilation.
    Branconnier MP; Hess DR
    Respir Care; 2005 Dec; 50(12):1649-53. PubMed ID: 16318646
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Relative amount of albuterol delivered to lung receptors from a metered-dose inhaler and nebulizer solution. Bioassay by histamine bronchoprovocation.
    Blake KV; Hoppe M; Harman E; Hendeles L
    Chest; 1992 Feb; 101(2):309-15. PubMed ID: 1310456
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A comparison of metered-dose inhaled albuterol versus endotracheal liquid bolus albuterol for the treatment of bronchoconstriction.
    Johnston DA; Gilmore TW; Gosselin KP
    Respir Care; 2015 May; 60(5):627-35. PubMed ID: 25587162
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Pilot study of bronchodilator response to inhaled albuterol delivered by metered-dose inhaler and a novel dry powder inhaler.
    Kemp JP; Hill MR; Vaughan LM; Meltzer EO; Welch MJ; Ostrom NK
    Ann Allergy Asthma Immunol; 1997 Oct; 79(4):322-6. PubMed ID: 9357377
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of heliox on albuterol delivery by metered-dose inhaler in pediatric in vitro models of mechanical ventilation.
    Garner SS; Wiest DB; Stevens CE; Habib DM
    Pharmacotherapy; 2006 Oct; 26(10):1396-402. PubMed ID: 16999649
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.
    Ari A; Atalay OT; Harwood R; Sheard MM; Aljamhan EA; Fink JB
    Respir Care; 2010 Jul; 55(7):845-51. PubMed ID: 20587095
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.