These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 8258960)

  • 21. [Assessment of salt intake in hemodialysis].
    Maduell F; Navarro V
    Nefrologia; 2001; 21(1):71-7. PubMed ID: 11344965
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An evaluation of blood volume changes during ultrafiltration pulses and natriuretic peptides in the assessment of dry weight in hemodialysis patients.
    van de Pol AC; Frenken LA; Moret K; Baumgarten R; van der Sande FM; Beerenhout CM; Kooman JP; Leunissen KM
    Hemodial Int; 2007 Jan; 11(1):51-61. PubMed ID: 17257357
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Non-invasive method for preventing intradialytic hypotension: A pilot study.
    Saxena A; Sharma RK; Gupta A; John MM
    Saudi J Kidney Dis Transpl; 2015 Sep; 26(5):896-905. PubMed ID: 26354560
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Interstitial correction of blood volume decrease during hemodialysis.
    Kouw PM; De Vries PM; Oe PL
    Int J Artif Organs; 1989 Oct; 12(10):626-31. PubMed ID: 2807587
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The influence of dialysate sodium and variable ultrafiltration on fluid balance during hemodialysis.
    de Vries PM; Kouw PM; Olthof CG; Solf A; Schuenemann B; Oe LP; Quellhorst E; Donker AJ
    ASAIO Trans; 1990; 36(4):821-4. PubMed ID: 2268486
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Determination of dry weight of hemodialyzed patients on the basis of the ratio of extracellular fluid volume to total body fluid volume as measured by multifrequency impedance].
    Lopot F; Kotyk P; Forejt J
    Vnitr Lek; 1995 Nov; 41(11):753-8. PubMed ID: 8553593
    [TBL] [Abstract][Full Text] [Related]  

  • 27. On-line optical sensing of blood volume changes to prevent intradialytic hypovolemia.
    Kianfar C; Rothera C; Lindsay RM
    CANNT J; 1999; 9(4):29-32; quiz 33-4, 35-40. PubMed ID: 15714786
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Relative underestimation of fluid removal during hemodialysis hypotension measured by whole body bioimpedance.
    Zaluska WT; Schneditz D; Kaufman AM; Morris AT; Levin NW
    ASAIO J; 1998; 44(6):823-7. PubMed ID: 9831092
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Haemodialysis with on-line monitoring equipment: tools or toys?
    Locatelli F; Buoncristiani U; Canaud B; Köhler H; Petitclerc T; Zucchelli P
    Nephrol Dial Transplant; 2005 Jan; 20(1):22-33. PubMed ID: 15632348
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Blood Volume Monitoring to Assess Dry Weight in Pediatric Chronic Hemodialysis Patients.
    Srisuwan K; Hongsawong N; Lumpaopong A; Thirakhupt P; Chulamokha Y
    J Med Assoc Thai; 2015 Nov; 98(11):1089-96. PubMed ID: 26817179
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Blood volume analysis as a guide for dry weight determination in chronic hemodialysis patients: a crossover study.
    Malha L; Fattah H; Modersitzki F; Goldfarb DS
    BMC Nephrol; 2019 Feb; 20(1):47. PubMed ID: 30744587
    [TBL] [Abstract][Full Text] [Related]  

  • 32. QRS amplitude and volume changes during hemodialysis.
    Ojanen S; Kööbi T; Korhonen P; Mustonen J; Pasternack A
    Am J Nephrol; 1999; 19(3):423-7. PubMed ID: 10393382
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Determination of circulating blood volume by continuously monitoring hematocrit during hemodialysis.
    Leypoldt JK; Cheung AK; Steuer RR; Harris DH; Conis JM
    J Am Soc Nephrol; 1995 Aug; 6(2):214-9. PubMed ID: 7579087
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Prediction of dry weight through changes in blood volume and plasma cyclic 3',5'-guanosine monophosphate in patients under maintenance hemodialysis.
    Wann GL; Tsai CS; Lin SH; Huang WD; Chu P; Chen GS; Lin YF
    ASAIO J; 1998; 44(5):M569-73. PubMed ID: 9804497
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Enhanced fluid removal guided by blood volume monitoring during chronic hemodialysis.
    Steuer RR; Germain MJ; Leypoldt JK; Cheung AK
    Artif Organs; 1998 Aug; 22(8):627-32. PubMed ID: 9702312
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Intradialytic hypotension: The role of volemia].
    Basile C
    G Ital Nefrol; 2006; 23(1):22-8. PubMed ID: 16521072
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The impact of hydration status on the assessment of lean body mass by body electrical impedance in dialysis patients.
    de Fijter CW; de Fijter MM; Oe LP; Donker AJ; de Vries PM
    Adv Perit Dial; 1993; 9():101-4. PubMed ID: 8105899
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Recent advances in the prevention and management of intradialytic hypotension.
    Palmer BF; Henrich WL
    J Am Soc Nephrol; 2008 Jan; 19(1):8-11. PubMed ID: 18178796
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Relative blood volume based biofeedback during haemodialysis.
    Dasselaar JJ
    J Ren Care; 2007; 33(2):59-65. PubMed ID: 17702507
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Automatic feedback control of relative blood volume changes during hemodialysis improves blood pressure stability during and after dialysis.
    Franssen CF; Dasselaar JJ; Sytsma P; Burgerhof JG; de Jong PE; Huisman RM
    Hemodial Int; 2005 Oct; 9(4):383-92. PubMed ID: 16219059
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.