BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 8259040)

  • 21. Prospective study of the incidence of ultrasound-detected hepatic hematomas due to percutaneous Menghini needle liver biopsy and laparoscopy-guided Silverman needle biopsy.
    Glaser J; Mann O; Siegmüller M; Pausch J
    Ital J Gastroenterol; 1994 Sep; 26(7):338-41. PubMed ID: 7812026
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Safety of omitting routine bleeding tests prior to image-guided musculoskeletal core needle biopsy.
    Shif Y; Kung JW; McMahon CJ; Mhuircheartaigh JN; Lin YC; Anderson ME; Wu JS
    Skeletal Radiol; 2018 Feb; 47(2):215-221. PubMed ID: 28983679
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Ultrasound guided fine- and coarse-needle puncture of the abdominal and retroperitoneal space].
    Binder T; Swobodnik W; Wechsler JG; Löschinger K; Eckert E; Schoengen A; Heimpel H; Ditschuneit H
    Dtsch Med Wochenschr; 1987 Jan; 113(2):43-8. PubMed ID: 3322762
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Two cases of lethal complications following ultrasound-guided percutaneous fine-needle biopsy of the liver.
    Drinković I; Brkljacić B
    Cardiovasc Intervent Radiol; 1996; 19(5):360-3. PubMed ID: 8781161
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transjugular biopsy of the liver in pediatric and adult patients using an 18-gauge automated core biopsy needle: a retrospective review of 410 consecutive procedures.
    Smith TP; Presson TL; Heneghan MA; Ryan JM
    AJR Am J Roentgenol; 2003 Jan; 180(1):167-72. PubMed ID: 12490497
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Diagnostic Accuracy and Safety of CT-Guided Percutaneous Transthoracic Needle Biopsies: 14-Gauge versus 22-Gauge Needles.
    Ocak S; Duplaquet F; Jamart J; Pirard L; Weynand B; Delos M; Eucher P; Rondelet B; Dupont M; Delaunois L; Sibille Y; Dahlqvist C
    J Vasc Interv Radiol; 2016 May; 27(5):674-81. PubMed ID: 27017121
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Ultrasound-guided biopsies of abdominal organs with an automatic biopsy system. A retrospective analysis of the quality of biopsies and of hemorrhagic complications.
    Riemann B; Menzel J; Schiemann U; Domschke W; Konturek JW
    Scand J Gastroenterol; 2000 Jan; 35(1):102-7. PubMed ID: 10672843
    [TBL] [Abstract][Full Text] [Related]  

  • 28. US-guided percutaneous needle biopsy of the spleen using 18-gauge versus 21-gauge needles.
    Liang P; Gao Y; Wang Y; Yu X; Yu D; Dong B
    J Clin Ultrasound; 2007; 35(9):477-82. PubMed ID: 17583561
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison between the 21-gauge Urocut needle and the 21-gauge Surecut needle in echo-guided percutaneous biopsy of neoplastic liver lesions.
    Solmi L; Muratori R; Brambati M; Gandolfi L
    Surg Endosc; 1989; 3(1):38-41. PubMed ID: 2652352
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [CT-guided percutaneous biopsies for the classification of focal liver lesions: a comparison between 14 G and 18 G puncture biopsy needles].
    Haage P; Piroth W; Staatz G; Adam G; Günther RW
    Rofo; 1999 Jul; 171(1):44-8. PubMed ID: 10464504
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Comparison of safety and sensitivity in diagnosis of liver lesion between ultrasound-guided 16 gauges and 18 gauges core needle biopsy].
    Chen F; Wang B; Chen LZ
    Zhonghua Yi Xue Za Zhi; 2007 Mar; 87(12):823-5. PubMed ID: 17565865
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparison of transjugular and plugged-percutaneous liver biopsy in patients with impaired coagulation.
    Sawyerr AM; McCormick PA; Tennyson GS; Chin J; Dick R; Scheuer PJ; Burroughs AK; McIntyre N
    J Hepatol; 1993 Jan; 17(1):81-5. PubMed ID: 8445223
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Incidence of ultrasound detectable liver hematomas after ultrasound controlled fine needle puncture with the 0.95 mm cutting biopsy cannula in comparison with percutaneous liver biopsy with the 1.4 mm Menghini needle].
    Glaser J; Mann O; von Eiff M; Pfahlberg A; Pausch J
    Med Klin (Munich); 1995 Mar; 90(3):131-3. PubMed ID: 7723713
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of needle gauge and lobe laterality on parenchymal liver biopsy outcome: a retrospective analysis.
    Vijayaraghavan GR; Vedantham S; Rangan V; Karam A; Zheng L; Roychowdhury A; Hussain S
    Abdom Imaging; 2015 Jun; 40(5):1223-9. PubMed ID: 25367814
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ultrasound-guided fine needle aspiration biopsy of portal vein thrombosis in liver cirrhosis: results in 15 patients.
    De Sio I; Castellano L; Calandra M; Romano M; Persico M; Del Vecchio-Blanco C
    J Gastroenterol Hepatol; 1995; 10(6):662-5. PubMed ID: 8580410
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Thyroid biopsies: fine-needle aspiration biopsy versus spring-activated core biopsy needle in 102 patients.
    Quinn SF; Nelson HA; Demlow TA
    J Vasc Interv Radiol; 1994; 5(4):619-23. PubMed ID: 7949720
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Low Utility of Screening Hematologic Testing for Image-Guided Biopsies in Patients Without Bleeding Risks.
    Matsumoto MM; Altman A; Jothishankar B; Funaki B; Chang PJ
    AJR Am J Roentgenol; 2020 Nov; 215(5):1279-1285. PubMed ID: 32901565
    [No Abstract]   [Full Text] [Related]  

  • 38. US-guided percutaneous liver biopsy with plugging of the needle track: a prospective study in 72 high-risk patients.
    Zins M; Vilgrain V; Gayno S; Rolland Y; Arrivé L; Denninger MH; Vullierme MP; Najmark D; Menu Y; Nahum H
    Radiology; 1992 Sep; 184(3):841-3. PubMed ID: 1509076
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Ultrasound-guided fine-needle biopsy of focal liver lesions: techniques, diagnostic accuracy and complications. A retrospective study on 2091 biopsies.
    Buscarini L; Fornari F; Bolondi L; Colombo P; Livraghi T; Magnolfi F; Rapaccini GL; Salmi A
    J Hepatol; 1990 Nov; 11(3):344-8. PubMed ID: 2290025
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Central venous catheter placement in patients with disorders of hemostasis.
    Doerfler ME; Kaufman B; Goldenberg AS
    Chest; 1996 Jul; 110(1):185-8. PubMed ID: 8681626
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.