These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 8259425)

  • 1. Determination of optimal time window for liver scanning with CT during arterial portography.
    Graf O; Dock WI; Lammer J; Thurnher S; Eibenberger KL; Wildling R; Niederle B; Lang EK; Lechner G
    Radiology; 1994 Jan; 190(1):43-7. PubMed ID: 8259425
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Helical CT during arterial portography: optimization of contrast enhancement and scanning parameters.
    Freeny PC; Nghiem HV; Winter TC
    Radiology; 1995 Jan; 194(1):83-90. PubMed ID: 7997587
    [TBL] [Abstract][Full Text] [Related]  

  • 3. MDCT of the pancreas: optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement.
    Kondo H; Kanematsu M; Goshima S; Miyoshi T; Shiratori Y; Onozuka M; Moriyama N; Bae KT
    AJR Am J Roentgenol; 2007 Mar; 188(3):751-6. PubMed ID: 17312064
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Blood supply of liver metastatic tumors observed by both CT arterial portography via superior mesenterica arterial and multi-slice spiral CT perfusion imaging].
    Shi GF; Wang Q; Li ZG; Wang SJ; DU Y; Wang YN
    Ai Zheng; 2007 Nov; 26(11):1257-62. PubMed ID: 17991329
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Homogeneous enhancement of hepatic parenchyma: MR imaging during arterial portography versus CT during arterial portography.
    Fujita T; Honjo K; Ito K; Matsumoto T; Matsunaga N
    Abdom Imaging; 1998; 23(1):51-5. PubMed ID: 9437063
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimizing CT portography: a prospective comparison of injection into the splenic versus superior mesenteric artery.
    Little AF; Baron RL; Peterson MS; Confer SR; Dodd GD; Chambers TP; Federle MP; Oliver JH; Orons PD; Sammon JK
    Radiology; 1994 Dec; 193(3):651-5. PubMed ID: 7972803
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Methodological assessment of combined spiral CT angiography and CT arterial portography.
    Kanematsu M; Imaeda T; Hoshi H; Yokoyama R; Mizuno S
    Abdom Imaging; 1997; 22(4):404-9. PubMed ID: 9157861
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Triple-phase computed tomography during arterial portography with bolus tracking for hepatic tumors.
    Nakai M; Sato M; Ikoma A; Nakata K; Sahara S; Takasaka I; Minamiguchi H; Kawai N; Sonomura T; Kishi K
    Jpn J Radiol; 2010 Feb; 28(2):149-56. PubMed ID: 20182850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hypervascular hepatocellular carcinomas: bolus tracking with a 40-detector CT scanner to time arterial phase imaging.
    Sultana S; Awai K; Nakayama Y; Nakaura T; Liu D; Hatemura M; Funama Y; Morishita S; Yamashita Y
    Radiology; 2007 Apr; 243(1):140-7. PubMed ID: 17329690
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CT arterial portography of the abdomen: effect of injecting papaverine into the mesenteric artery on hepatic contrast enhancement.
    Soyer P; Lacheheb D; Levesque M
    AJR Am J Roentgenol; 1993 Jun; 160(6):1213-5. PubMed ID: 8498218
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spiral CT arterial portography of the liver.
    Bluemke DA; Fishman EK
    Radiology; 1993 Feb; 186(2):576-9. PubMed ID: 8421769
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of computed tomography arterial portography scan timing using different bolus tracking methods.
    Chiba A; Harada K; Ohashi Y; Numasawa K; Imai T; Hayasaka S
    Radiol Phys Technol; 2020 Mar; 13(1):92-97. PubMed ID: 32056063
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of prostaglandin E1 on contrast enhanced CT of the liver: statistical analysis during arterial portography.
    Abe Y; Murata S; Tajima H; Hayashi H; Kumazaki T
    J Nippon Med Sch; 2003 Aug; 70(4):307-12. PubMed ID: 12928710
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Anatomy of the right anterosuperior area (segment 8) of the liver: evaluation with helical CT during arterial portography.
    Cho A; Okazumi S; Takayama W; Takeda A; Iwasaki K; Sasagawa S; Natsume T; Kono T; Kondo S; Ochiai T; Ryu M
    Radiology; 2000 Feb; 214(2):491-5. PubMed ID: 10671598
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of saline pushing after contrast material injection in abdominal multidetector computed tomography with the use of different iodine concentrations.
    Tatsugami F; Matsuki M; Kani H; Tanikake M; Miyao M; Yoshikawa S; Narabayashi I
    Acta Radiol; 2006 Mar; 47(2):192-7. PubMed ID: 16604967
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of contrast material for spiral CT of the abdomen: comparison of hepatic enhancement and vascular attenuation for three different contrast media at two different delay times.
    Herts BR; Paushter DM; Einstein DM; Zepp R; Friedman RA; Obuchowski N
    AJR Am J Roentgenol; 1995 Feb; 164(2):327-31. PubMed ID: 7839963
    [TBL] [Abstract][Full Text] [Related]  

  • 17. CT during arterial portography: comparison of injection into the splenic versus superior mesenteric artery.
    McDermott VG; Lawrance JA; Paulson EK; Keogan MT; Suhocki PV; DeLong DM; Nelson RC
    Radiology; 1996 Jun; 199(3):627-31. PubMed ID: 8637977
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of injection rates of contrast material on arterial phase hepatic CT.
    Kim T; Murakami T; Takahashi S; Tsuda K; Tomoda K; Narumi Y; Oi H; Nakamura H
    AJR Am J Roentgenol; 1998 Aug; 171(2):429-32. PubMed ID: 9694469
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multi-detector row helical CT of the liver: quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT--a prospective randomized study.
    Tsurusaki M; Sugimoto K; Fujii M; Sugimura K
    Radiat Med; 2004; 22(4):239-45. PubMed ID: 15468944
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CT portography by direct intrasplenic contrast injection: a new technique.
    Jain R; Sawhney S; Sahni P; Taneja K; Berry M
    Abdom Imaging; 1999; 24(3):272-7. PubMed ID: 10227892
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.