21. Right-left ventricular output balance in the totally implantable artificial heart. Olsen DB; White RK; Long JW; Khanwilkar PS Int J Artif Organs; 1991 Jun; 14(6):359-64. PubMed ID: 1885244 [TBL] [Abstract][Full Text] [Related]
22. Early changes in circulating blood volume and volume regulating humoral factors after implantation of an electrohydraulic total artificial heart. Nakamura M; Tatsumi E; Masuzawa T; Taenaka Y; Nakatani T; Sohn Y; Endo S; Ohno T; Takiura K; Nishimura T; Takewa Y; Wakisaka Y; Takano H ASAIO J; 1997; 43(5):M663-8. PubMed ID: 9360129 [TBL] [Abstract][Full Text] [Related]
23. Development of an efficient electrohydraulic total artificial heart. Millner A; Menn D; Ochs B; Vaughan S; Kung RT ASAIO Trans; 1990; 36(3):M245-9. PubMed ID: 2252668 [TBL] [Abstract][Full Text] [Related]
24. An annular compliance chamber for the Pennsylvania State University electric total artificial heart. Reibson JD; Rosenberg G; Snyder AJ; Cleary TJ; Donachy JH; Felder G; Pierce WS ASAIO J; 1993; 39(3):M415-8. PubMed ID: 8268569 [TBL] [Abstract][Full Text] [Related]
25. Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart. Rosenberg G; Landis DL; Phillips WM; Stallsmith J; Pierce WS Trans Am Soc Artif Intern Organs; 1978; 24():341-4. PubMed ID: 362675 [TBL] [Abstract][Full Text] [Related]
26. Eight-year experience with a continuous-flow total artificial heart in calves. Cohn WE; Handy KM; Parnis SM; Conger JL; Winkler JA; Frazier OH ASAIO J; 2014; 60(1):25-30. PubMed ID: 24281122 [TBL] [Abstract][Full Text] [Related]
28. Cardiac output and left atrial pressure monitoring by right ventricular pressure waveform analysis for potential implantable device application. Xu D; Olivier NB; Mukkamala R IEEE Trans Biomed Eng; 2009 Sep; 56(9):2335-9. PubMed ID: 19457736 [TBL] [Abstract][Full Text] [Related]
29. Automatic control of the artificial heart. Pierce WS; Landis D; O'Bannon W; Donachy JH; White W; Phillips W; Brighton JA Trans Am Soc Artif Intern Organs; 1976; 22():347-56. PubMed ID: 951850 [TBL] [Abstract][Full Text] [Related]
30. In vivo performance evaluation of a transcutaneous energy and information transmission system for the total artificial heart. Ahn JM; Kang DW; Kim HC; Min BG ASAIO J; 1993; 39(3):M208-12. PubMed ID: 8268530 [TBL] [Abstract][Full Text] [Related]
31. Evaluation of treadmill exercise on total artificial heart recipients. Chiang BY; Olsen DB; Gaykowski R; Dries D; Burns GL; Hamanaka Y; Murray KD; Ilyia E; Dew PA; Hughes SD Trans Am Soc Artif Intern Organs; 1984; 30():514-9. PubMed ID: 6533934 [No Abstract] [Full Text] [Related]
32. Evaluation of a pulsatile pediatric ventricular assist device in an acute right heart failure model. Shum-Tim D; Duncan BW; Hraska V; Friehs I; Shin'oka T; Jonas RA Ann Thorac Surg; 1997 Nov; 64(5):1374-80. PubMed ID: 9386707 [TBL] [Abstract][Full Text] [Related]
33. Continuing development of the Cleveland Clinic-Nimbus total artificial heart. Rintoul TC; Butler KC; Thomas DC; Carriker JW; Maher TR; Kiraly RJ; Massiello A; Himley SC; Chen JF; Fukamachi K ASAIO J; 1993; 39(3):M168-71. PubMed ID: 8268522 [TBL] [Abstract][Full Text] [Related]
34. Vascular tone estimation in patients implanted with the AbioCor implantable replacement heart. Kung RT; Zhang H Artif Organs; 2004 Jun; 28(6):543-8. PubMed ID: 15153146 [TBL] [Abstract][Full Text] [Related]
35. One month survival with the undulation pump total artificial heart in a goat. Abe Y; Chinzei T; Isoyama T; Ono T; Mochizuki S; Saito I; Iwasaki K; Ishimaru M; Karita T; Kuono A; Baba K; Imachi K Artif Organs; 2001 Jan; 25(1):69-71. PubMed ID: 11167565 [TBL] [Abstract][Full Text] [Related]
36. Progress of an electrohydraulic total artificial heart system with a separate energy converter. Masuzawa T; Tatsumi E; Taenaka Y; Nakamura M; Endo S; Takano H; Koshiji K; Fukui Y; Murai T; Tsukahara K ASAIO J; 1999; 45(5):471-7. PubMed ID: 10503628 [TBL] [Abstract][Full Text] [Related]
37. In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps. Farrar DJ; Litwak P; Lawson JH; Ward RS; White KA; Robinson AJ; Rodvien R; Hill JD J Thorac Cardiovasc Surg; 1988 Feb; 95(2):191-200. PubMed ID: 3339889 [TBL] [Abstract][Full Text] [Related]
38. Newly designed eccentric roller type total artificial heart. Wada H; Fukunaga S; Watari M; Orihashi K; Sueda T; Matsuura Y Hiroshima J Med Sci; 2000 Mar; 49(1):7-14. PubMed ID: 10824452 [TBL] [Abstract][Full Text] [Related]
39. Animal implantation results with the Utah-100 total artificial heart. Kinoshita M; Pantalos GM; Holfert JW; Dew PA; Burns GL; Mohammad SF; Olsen DB ASAIO J; 1992; 38(2):108-12. PubMed ID: 1421602 [TBL] [Abstract][Full Text] [Related]
40. The Cleveland Clinic-Nimbus total artificial heart. In vivo hemodynamic performance in calves and preclinical studies. McCarthy PM; Fukamachi K; Fukumura F; Muramoto K; Golding LA; Harasaki H J Thorac Cardiovasc Surg; 1994 Sep; 108(3):420-8. PubMed ID: 8078335 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]