These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 8268640)

  • 21. Acute Type A Aortic Dissection Treated Using a Tubular Stent-Graft in the Ascending Aorta and a Multibranched Stent-Graft in the Aortic Arch.
    Kölbel T; Detter C; Carpenter SW; Rohlffs F; von Kodolitsch Y; Wipper S; Reichenspurner H; Debus ES; Tsilimparis N
    J Endovasc Ther; 2017 Feb; 24(1):75-80. PubMed ID: 27881689
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Avoidance of proximal endoleak using a hybrid stent graft in arch replacement and descending aorta stenting.
    Tsagakis K; Kamler M; Kuehl H; Kowalczyk W; Tossios P; Thielmann M; Osswald B; Erbel R; Eggebrecht H; Jakob H
    Ann Thorac Surg; 2009 Sep; 88(3):773-9. PubMed ID: 19699896
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel-based device in aortic dissection.
    Huang CY; Weng SH; Weng CF; Chen WY; Chen IM; Hsu CP; Shih CC
    J Thorac Cardiovasc Surg; 2013 Sep; 146(3):623-30. PubMed ID: 23040193
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Staged proximal deployment of the Zenith TX2 thoracic stent-graft: a novel technique to improve conformance to the aortic arch.
    Kölbel T; Resch TA; Dias N; Björses K; Sonesson B; Malina M
    J Endovasc Ther; 2009 Oct; 16(5):598-602. PubMed ID: 19842728
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transcatheter placement of an intraluminal prosthesis for the thoracic aorta. A new approach to aortic dissections.
    Yoshida H; Kakino T; Kajitani M; Goh K; Gohda T; Yasuda K; Tanabe T
    ASAIO Trans; 1991; 37(3):M272-3. PubMed ID: 1751144
    [TBL] [Abstract][Full Text] [Related]  

  • 26. New approach to aortic dissection: development of an insertable aortic prosthesis.
    Yoshida H; Yasuda K; Tanabe T
    Ann Thorac Surg; 1994 Sep; 58(3):806-10. PubMed ID: 7944707
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Risk factors for stent graft-induced new entry after thoracic endovascular aortic repair for Stanford type B aortic dissection.
    Jang H; Kim MD; Kim GM; Won JY; Ko YG; Choi D; Joo HC; Lee DY
    J Vasc Surg; 2017 Mar; 65(3):676-685. PubMed ID: 28236916
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Transcatheter Inoue endovascular graft for treatment of canine aortic dissection.
    Htay T; Fujiwara H; Sato M; Tanaka M; Sasayama S; Inoue K
    Heart Vessels; 1996; 11(2):80-5. PubMed ID: 8836755
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The impact of bird-beak configuration on aortic remodeling of distal arch pathology after thoracic endovascular aortic repair with the Zenith Pro-Form TX2 thoracic endograft.
    Hsu HL; Chen CK; Chen PL; Chen IM; Hsu CP; Chen CW; Shih CC
    J Vasc Surg; 2014 Jan; 59(1):80-8. PubMed ID: 24139983
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Stent-graft detachment from aortic wall after stent-graft repair of acute aortic dissection.
    Kato N; Shimono T; Hirano T; Ishida M; Takeda K
    J Vasc Surg; 2003 Nov; 38(5):1130-1. PubMed ID: 14603227
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Initial results of thoracic endovascular repair for uncomplicated type B aortic dissection involving the arch vessels using a semicustom-made thoracic fenestrated stent graft.
    Fukushima S; Ohki T; Toya N; Shukuzawa K; Ito E; Murakami Y; Akiba T
    J Vasc Surg; 2019 Jun; 69(6):1694-1703. PubMed ID: 30786986
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Will stent-graft repair emerge as treatment of choice for acute type B dissection?
    Dake MD; Wang DS
    Semin Vasc Surg; 2006 Mar; 19(1):40-7. PubMed ID: 16533691
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impermeability to blood of the E-vita open plus hybrid stent-graft: experimental and clinical evaluation.
    Tsagakis K; Pizanis N; Baba HA; Wendt D; Wisbrun N; Altenbernd J; Eggebrecht H; Kamler M; Jakob H
    J Endovasc Ther; 2010 Jun; 17(3):340-8. PubMed ID: 20557173
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Successful management of a combined ruptured Stanford type B aortic dissection and malperfusion syndrome with an endoluminal graft.
    Kpodonu J; Ramaiah VG; Diethrich EB
    Interact Cardiovasc Thorac Surg; 2008 Apr; 7(2):339-41. PubMed ID: 18227123
    [TBL] [Abstract][Full Text] [Related]  

  • 35. New Advances in Endovascular Therapy: Endovascular Repair of a Chronic DeBakey Type II Aortic Dissection With a Scalloped Stent-Graft Designed for the Ascending Aorta.
    Rohlffs F; Tsilimparis N; Detter C; von Kodolitsch Y; Debus S; Kölbel T
    J Endovasc Ther; 2016 Feb; 23(1):182-5. PubMed ID: 26668129
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Endovascular repair of ascending aortic dissection.
    Pontes JC; Dias AM; Duarte JJ; Benfatti RA; Gardenal N
    Rev Bras Cir Cardiovasc; 2013 Mar; 28(1):145-7. PubMed ID: 23739942
    [TBL] [Abstract][Full Text] [Related]  

  • 37. eComment: Can we use endovascular graft stenting in all type B dissections?
    Ates M; Yekeler I
    Interact Cardiovasc Thorac Surg; 2008 Apr; 7(2):341. PubMed ID: 18381368
    [No Abstract]   [Full Text] [Related]  

  • 38. Implantation sequence modification averts distal stent graft-induced new entry after endovascular repair of Stanford type B aortic dissection.
    Chen IM; Huang CY; Weng SH; Lin PY; Chen PL; Chen WY; Shih CC
    J Vasc Surg; 2016 Aug; 64(2):281-288. PubMed ID: 27139785
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.
    He H; Yao K; Nie WP; Wang Z; Liang Q; Shu C; Dardik A
    Eur J Vasc Endovasc Surg; 2015 Oct; 50(4):450-9. PubMed ID: 26100449
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Treatment of acute aortic type B dissection with stent-grafts.
    Hausegger KA; Tiesenhausen K; Schedlbauer P; Oberwalder P; Tauss J; Rigler B
    Cardiovasc Intervent Radiol; 2001; 24(5):306-12. PubMed ID: 11815835
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.