These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 8269131)

  • 1. Prosthetic valve function under simulated low cardiac output conditions: preliminary observations.
    Bodnar E; Reul H; Schmitz B
    J Heart Valve Dis; 1993 May; 2(3):348-51. PubMed ID: 8269131
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves.
    Gerosa G; Tarzia V; Rizzoli G; Bottio T
    J Thorac Cardiovasc Surg; 2006 May; 131(5):1058-64. PubMed ID: 16678590
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves.
    Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G
    J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: implications for in vivo assessment of prosthetic valve function.
    Fontaine AA; Heinrich RS; Walker PG; Pedersen EM; Scheidegger MB; Boesiger P; Walton SP; Yoganathan AP
    J Heart Valve Dis; 1996 Jan; 5(1):66-73. PubMed ID: 8834728
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves.
    Bottio T; Caprili L; Casarotto D; Gerosa G
    J Thorac Cardiovasc Surg; 2004 Sep; 128(3):457-62. PubMed ID: 15354108
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro evaluation of the long-body On-X bileaflet heart valve.
    Hwang NH; Reul H; Reinhard P
    J Heart Valve Dis; 1998 Sep; 7(5):561-8. PubMed ID: 9793857
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].
    Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Harvested porcine mitral xenograft fixation: impact on fluid dynamic performance.
    Jensen MO; Lemmon JD; Gessaghi VC; Conrad CP; Levine RA; Yoganathan AP
    J Heart Valve Dis; 2001 Jan; 10(1):111-24. PubMed ID: 11206757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computational fluid dynamics study of a protruded-hinge bileaflet mechanical heart valve.
    Wang J; Yao H; Lim CJ; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2001 Mar; 10(2):254-262; discussion 263. PubMed ID: 11297213
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hydrodynamic comparison of biological prostheses during progressive valve calcification in a simulated exercise situation. An in vitro study.
    Bakhtiary F; Dzemali O; Steinseiffer U; Schmitz C; Glasmacher B; Moritz A; Kleine P
    Eur J Cardiothorac Surg; 2008 Nov; 34(5):960-3. PubMed ID: 18774723
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel pulse duplicator system: evaluation of different valve prostheses.
    Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G
    Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.
    Shu MC; Gross JM; O'Rourke KK; Yoganathan AP
    J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In-vitro testing of three totally supra-annular bileaflet mechanical valves: hydrodynamics in the Sheffield pulse duplicator.
    Bottio T; Tarzia V; Rizzoli G; Gerosa G
    J Heart Valve Dis; 2008 Mar; 17(2):222-6. PubMed ID: 18512495
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Asynchronous closure and leaflet impact velocity of bileaflet mechanical heart valves.
    Wu ZJ; Hwang NH
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S38-49. PubMed ID: 8581210
    [TBL] [Abstract][Full Text] [Related]  

  • 15. St. Jude Medical cardiac valve prosthesis: in vitro studies.
    Emery RW; Nicoloff DM
    J Thorac Cardiovasc Surg; 1979 Aug; 78(2):269-76. PubMed ID: 459535
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bubble formation on St. Jude Medical mechanical heart valves: an in-vitro study.
    Milo S; Gutfinger C; Chu GY; Gharib M
    J Heart Valve Dis; 2003 May; 12(3):406-10. PubMed ID: 12803343
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective randomized comparison of CarboMedics and St. Jude Medical bileaflet mechanical heart valve prostheses: ten-year follow-up.
    Bryan AJ; Rogers CA; Bayliss K; Wild J; Angelini GD
    J Thorac Cardiovasc Surg; 2007 Mar; 133(3):614-22. PubMed ID: 17320553
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodynamics of high-performance bileaflet valves: comparison to simulated clinical Doppler measurements.
    Dohmen G; Schmitz C; Schmitz-Rode T; Steinseifer U; Autschbach R
    J Heart Valve Dis; 2006 Jul; 15(4):549-56. PubMed ID: 16901053
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tubular heart valves: a new tissue prosthesis design--preclinical evaluation of the 3F aortic bioprosthesis.
    Cox JL; Ad N; Myers K; Gharib M; Quijano RC
    J Thorac Cardiovasc Surg; 2005 Aug; 130(2):520-7. PubMed ID: 16077422
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New generation tissue valves. Their in vitro function in the mitral position.
    Walker DK; Scotten LN; Brownlee RT
    J Thorac Cardiovasc Surg; 1984 Oct; 88(4):573-82. PubMed ID: 6482489
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]