These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 8269147)

  • 1. Non-destructive evaluation techniques for prosthetic heart valves based on hologram interferometry. Part I.
    Zarubin AM; Geiger AW; von Bally G; Scheld HH
    J Heart Valve Dis; 1993 Jul; 2(4):440-7. PubMed ID: 8269147
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-destructive evaluation of prosthetic heart valves by holographic interferometry.
    Geiger AW; Zarubin A; Fahrenkamp A; Hertel M; von Bally G; Scheld HH
    J Heart Valve Dis; 1993 May; 2(3):343-7. PubMed ID: 8269130
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Non-destructive evaluation techniques for prosthetic heart valves based on hologram interferometry. Part II: Experimental results and clinical implications.
    Geiger AW; Zarubin AM; Fahrenkamp A; Konertz W; von Bally G; Scheld HH
    J Heart Valve Dis; 1993 Jul; 2(4):448-53. PubMed ID: 8269148
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Holographic interferometry: a new technique for in vitro investigations of prosthetic heart valves.
    Geiger AW; Zarubin A; von Bally G; Scheld HH
    Cardiovasc Surg; 1994 Feb; 2(1):104-9. PubMed ID: 8049913
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quality control of bioprosthetic heart valves by means of holographic interferometry.
    Deiwick M; Glasmacher B; Zarubin AM; Reul H; Geiger A; von Bally G; Stargardt A; Rau G; Scheld HH
    J Heart Valve Dis; 1996 Jul; 5(4):441-7; discussion 439-40. PubMed ID: 8858512
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comments on "Non-destructive evaluation of prosthetic heart valves by holographic interferometry".
    Bokros JC
    J Heart Valve Dis; 1993 May; 2(3):341-2. PubMed ID: 8269129
    [No Abstract]   [Full Text] [Related]  

  • 7. Comparative analysis of glutaraldehyde-preserved porcine xenografts and fresh or glutaraldehyde-treated human aortic valves by holographic interferometry.
    Geiger AW; Zarubin AM; Deiwick M; Asfour B; Fahrenkamp A; Hertel M; von Bally G; Scheld HH
    Cardiovasc Surg; 1994 Dec; 2(6):693-7. PubMed ID: 7858986
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Holographic interferometry and in vitro calcification: comparing pericardial versus porcine bioprostheses.
    Deiwick M; Glasmacher B; Tjan DT; Reul H; von Bally G; Scheld HH
    J Heart Valve Dis; 1998 Jul; 7(4):419-27. PubMed ID: 9697065
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Indication of cavitation in mechanical heart valve patients.
    Andersen TS; Johansen P; Paulsen PK; Nygaard H; Hasenkam JM
    J Heart Valve Dis; 2003 Nov; 12(6):790-6. PubMed ID: 14658822
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-resolution magnetic resonance imaging to characterize the geometry of fatigued porcine bioprosthetic heart valves.
    Smith DB; Sacks MS; Pattany PM; Schroeder R
    J Heart Valve Dis; 1997 Jul; 6(4):424-32. PubMed ID: 9263876
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro.
    Jennings LM; Butterfield M; Walker PG; Watterson KG; Fisher J
    J Heart Valve Dis; 2001 Mar; 10(2):269-75. PubMed ID: 11297215
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tubular heart valves: a new tissue prosthesis design--preclinical evaluation of the 3F aortic bioprosthesis.
    Cox JL; Ad N; Myers K; Gharib M; Quijano RC
    J Thorac Cardiovasc Surg; 2005 Aug; 130(2):520-7. PubMed ID: 16077422
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Late incidence and determinants of reoperation in patients with prosthetic heart valves.
    Ruel M; Kulik A; Rubens FD; Bédard P; Masters RG; Pipe AL; Mesana TG
    Eur J Cardiothorac Surg; 2004 Mar; 25(3):364-70. PubMed ID: 15019662
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flow in prosthetic heart valves: state-of-the-art and future directions.
    Yoganathan AP; Chandran KB; Sotiropoulos F
    Ann Biomed Eng; 2005 Dec; 33(12):1689-94. PubMed ID: 16389514
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiac valve replacement: a bioengineering approach.
    Korossis SA; Fisher J; Ingham E
    Biomed Mater Eng; 2000; 10(2):83-124. PubMed ID: 11086842
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Mechanism of the formation of orbital floor fractures. Holographic interferometry studies].
    Behrendt S; Rochels R
    Ophthalmologe; 1993 Feb; 90(1):31-3. PubMed ID: 8443445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The use of enzyme activated milk for in vitro simulation of prosthetic valve thrombosis.
    Keggen LA; Black MM; Lawford PV; Hose DR; Strachan JR
    J Heart Valve Dis; 1996 Jan; 5(1):74-83. PubMed ID: 8834729
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Trilogy pericardial valve: hemodynamic performance and calcification in adolescent sheep.
    Flameng W; Meuris B; De Visscher G; Cunanan C; Lane E; Verbeken E; Herijgers P; Herregods MC
    Ann Thorac Surg; 2008 Feb; 85(2):587-92. PubMed ID: 18222270
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dynamic simulation pericardial bioprosthetic heart valve function.
    Kim H; Lu J; Sacks MS; Chandran KB
    J Biomech Eng; 2006 Oct; 128(5):717-24. PubMed ID: 16995758
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Introduction of a flexible polymeric heart valve prosthesis with special design for aortic position.
    Daebritz SH; Fausten B; Hermanns B; Schroeder J; Groetzner J; Autschbach R; Messmer BJ; Sachweh JS
    Eur J Cardiothorac Surg; 2004 Jun; 25(6):946-52. PubMed ID: 15144993
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.