These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

300 related articles for article (PubMed ID: 8269571)

  • 1. Measurement of respiratory mechanics using the Puritan-Bennett 7200a ventilator.
    Chartrand D; Dionne B; Jodoin C; Lorange M; Lapointe A
    Can J Anaesth; 1993 Nov; 40(11):1076-83. PubMed ID: 8269571
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators.
    Lit LM; Doelken P; Mayo PH
    Respir Care; 2004 Sep; 49(9):1022-8. PubMed ID: 15329173
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved flow and pressure capabilities of the Datex-Ohmeda SmartVent anesthesia ventilator.
    Katz JA; Kallet RH; Alonso JA; Marks JD
    J Clin Anesth; 2000 Feb; 12(1):40-7. PubMed ID: 10773507
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy of pressure support in compensating for apparatus work.
    Bersten AD; Rutten AJ; Vedig AE
    Anaesth Intensive Care; 1993 Feb; 21(1):67-71. PubMed ID: 8447610
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new application of an old method for respiratory mechanics measurements: the passive inflation method in newborn infants during pressure-controlled ventilation.
    Storme L; Riou Y; Logier R; Dubos JP; Kacet N; Rousseau S; Lequien P
    Pediatr Pulmonol; 1994 Oct; 18(4):244-54. PubMed ID: 7838624
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of ventilator performance on airway pressure release ventilation: a model lung study.
    Yoshida T; Uchiyama A; Mashimo T; Fujino Y
    Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison of volume preset and pressure preset ventilators during daytime nasal ventilation in chronic respiratory failure].
    Perrin C; Wolter P; Berthier F; Tamisier R; Jullien V; Lemoigne F; Blaive B
    Rev Mal Respir; 2001 Feb; 18(1):41-8. PubMed ID: 14639176
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of Tidal Volume in Average Volume Assured Pressure Support Mode.
    Stagnara A; Baboi L; Nesme P; Subtil F; Louis B; Guérin C
    Respir Care; 2018 Sep; 63(9):1139-1146. PubMed ID: 29921607
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Volume-controlled inverse ratio ventilation: effect on dynamic hyperinflation and auto-PEEP.
    Valta P; Takala J
    Acta Anaesthesiol Scand; 1993 May; 37(4):323-8. PubMed ID: 8322558
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of respiratory mechanics software in microprocessor-controlled ventilators.
    Korst RJ; Orlando R; Yeston NS; Molin M; de Graff AC; Gluck E
    Crit Care Med; 1992 Aug; 20(8):1152-6. PubMed ID: 1643895
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Higher Fresh Gas Flow Rates Decrease Tidal Volume During Pressure Control Ventilation.
    Mohammad S; Gravenstein N; Gonsalves D; Vasilopoulos T; Lampotang S
    Anesth Analg; 2017 May; 124(5):1506-1511. PubMed ID: 28333703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ventilator-related causes of lung injury: the mechanical power.
    Gattinoni L; Tonetti T; Cressoni M; Cadringher P; Herrmann P; Moerer O; Protti A; Gotti M; Chiurazzi C; Carlesso E; Chiumello D; Quintel M
    Intensive Care Med; 2016 Oct; 42(10):1567-1575. PubMed ID: 27620287
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of the dynamic signal analysis approach in respiratory mechanics during noninvasive pressure support ventilation: a bench study.
    Chen Y; Yuan Y; Zhang H; Li F; Zhou X
    J Int Med Res; 2021 Feb; 49(2):300060521992184. PubMed ID: 33626940
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance characteristics of bilevel pressure ventilators: a lung model study.
    Bunburaphong T; Imanaka H; Nishimura M; Hess D; Kacmarek RM
    Chest; 1997 Apr; 111(4):1050-60. PubMed ID: 9106588
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of inspiratory rise time and inspiration termination criteria in new-generation mechanical ventilators: a lung model study.
    Chatmongkolchart S; Williams P; Hess DR; Kacmarek RM
    Respir Care; 2001 Jul; 46(7):666-77. PubMed ID: 11403698
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of respiratory system compliance by a flow recording method.
    Darowski M; Gottlieb-Inacio G; Ludwigs U; Hedenstierna G
    Acta Anaesthesiol Scand; 1995 May; 39(4):462-6. PubMed ID: 7676779
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of a bellows leak in an Ohmeda 7810 ventilator on room contamination, inspired oxygen, airway pressure, and tidal volume.
    Lampotang S; Sanchez JC; Chen B; Gravenstein N
    Anesth Analg; 2005 Jul; 101(1):151-4, table of contents. PubMed ID: 15976223
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.