These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 8270812)
21. Accuracy of post-void residual urine volume measurement using a portable ultrasound bladder scanner with real-time pre-scan imaging. Park YH; Ku JH; Oh SJ Neurourol Urodyn; 2011 Mar; 30(3):335-8. PubMed ID: 20658544 [TBL] [Abstract][Full Text] [Related]
22. Estimation of bladder volume using portable ultrasound in clam enterocystoplasty patients. Barrington JW; Jones A; Robinson J; Stephenson TP J Urol; 1996 Jan; 155(1):82-3. PubMed ID: 7490904 [TBL] [Abstract][Full Text] [Related]
23. Bladder management in acute care of stroke patients: a quality improvement project. Chan H J Neurosci Nurs; 1997 Jun; 29(3):187-90. PubMed ID: 9220366 [TBL] [Abstract][Full Text] [Related]
24. Monitoring urinary bladder volume and detecting post-operative urinary retention in children with an ultrasound scanner. Rosseland LA; Bentsen G; Hopp E; Refsum S; Breivik H Acta Anaesthesiol Scand; 2005 Nov; 49(10):1456-9. PubMed ID: 16223389 [TBL] [Abstract][Full Text] [Related]
25. Transabdominal ultrasound in the assessment of postvoid residual urine volume in patients after hysterectomy. Lertbunnaphong T; Inthasorn P; Boriboonhirunsarn D; Chuchotirot M; Russameecharoen K; Phattanachindakun B J Med Assoc Thai; 2006 Oct; 89 Suppl 4():S152-7. PubMed ID: 17725152 [TBL] [Abstract][Full Text] [Related]
26. Assessing bladder volumes in young children prior to instrumentation: accuracy of an automated ultrasound device compared to real-time ultrasound. Bevan C; Buntsma D; Stock A; Griffiths T; Donath S; Babl FE Acad Emerg Med; 2011 Aug; 18(8):816-21. PubMed ID: 21843216 [TBL] [Abstract][Full Text] [Related]
27. Management of temporary urinary retention after arthroscopic knee surgery in low-dose spinal anesthesia: development of a simple algorithm. Luger TJ; Garoscio I; Rehder P; Oberladstätter J; Voelckel W Arch Orthop Trauma Surg; 2008 Jun; 128(6):607-12. PubMed ID: 17968566 [TBL] [Abstract][Full Text] [Related]
28. Using Essence of Care benchmarking to develop clinical practice. Gilbert R Nurs Times; 2005 Jan 11-17; 101(2):54-5, 57, 59. PubMed ID: 15688924 [TBL] [Abstract][Full Text] [Related]
29. Measurement of bladder volume following cesarean section using bladderscan. Barrington JW; Edwards G; Ashcroft M; Adekanmi O Int Urogynecol J Pelvic Floor Dysfunct; 2001; 12(6):373-4. PubMed ID: 11795639 [TBL] [Abstract][Full Text] [Related]
30. Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting. Brouwer TA; van den Boogaard C; van Roon EN; Kalkman CJ; Veeger N J Clin Monit Comput; 2018 Dec; 32(6):1117-1126. PubMed ID: 29516310 [TBL] [Abstract][Full Text] [Related]
31. [Validity and reliability of bladder ultrasound imaging for noninvasive estimation of urine volume in a major outpatient surgery department]. Cabezón Gil P; López Yepes L; Fernández Pérez C; Barreales Tolosa L; Montoya González P; López Timoneda F Rev Esp Anestesiol Reanim; 2009 Oct; 56(8):479-84. PubMed ID: 19994616 [TBL] [Abstract][Full Text] [Related]
32. Bladder volume estimation in the elderly using a portable ultrasound-based measurement device. Topper AK; Holliday PJ; Fernie GR J Med Eng Technol; 1993; 17(3):99-103. PubMed ID: 8263906 [TBL] [Abstract][Full Text] [Related]
33. [The efficacy of portable 3-dimensional ultrasound scanning device (Bladder Scan BVI6100) for measurement of residual urine volume--comparison with transabdominal ultrasound estimation]. Watanabe A; Ichimatsu K; Ito T; Morii A; Yasuda K; Fujiuchi Y; Mizuno I; Fuse H Hinyokika Kiyo; 2008 Mar; 54(3):203-6. PubMed ID: 18411776 [TBL] [Abstract][Full Text] [Related]
34. Use of ultrasound bladder monitoring in children after caudal anaesthesia. Koomen E; Janssen S; Anderson BJ Paediatr Anaesth; 2002 Oct; 12(8):738-41. PubMed ID: 12472714 [TBL] [Abstract][Full Text] [Related]
35. Low incidence of postoperative urinary retention with the use of a nurse-led bladder scan protocol after hip and knee arthroplasty: a retrospective cohort study. Kort NP; Bemelmans Y; Vos R; Schotanus MGM Eur J Orthop Surg Traumatol; 2018 Feb; 28(2):283-289. PubMed ID: 28900757 [TBL] [Abstract][Full Text] [Related]
36. False reading of retained urine from a bladder scan. Morrell GA Urol Nurs; 2010; 30(2):147-8. PubMed ID: 20469574 [TBL] [Abstract][Full Text] [Related]
37. Reliability of an automatic ultrasound system in the post partum period in measuring urinary retention. Van Os AF; Van der Linden PJ Acta Obstet Gynecol Scand; 2006; 85(5):604-7. PubMed ID: 16752241 [TBL] [Abstract][Full Text] [Related]
38. Managing older patients with urinary retention in the Continence Clinic. Luk JK; Tam MW; Ho MC; Chan FH Hong Kong Med J; 2003 Feb; 9(1):15-9. PubMed ID: 12547951 [TBL] [Abstract][Full Text] [Related]
39. Patient-controlled epidural analgesia: the role of epidural fentanyl in peripartum urinary retention. Evron S; Muzikant G; Rigini N; Khazin V; Sessler DI; Sadan O; Ezri T Int J Obstet Anesth; 2006 Jul; 15(3):206-11. PubMed ID: 16798445 [TBL] [Abstract][Full Text] [Related]
40. Reliability of an automatic ultrasound system for detecting postpartum urinary retention after vaginal birth. Lukasse M; Cederkvist HR; Rosseland LA Acta Obstet Gynecol Scand; 2007 Oct; 86(10):1251-5. PubMed ID: 17851812 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]