These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 8277748)

  • 21. Developing glucose sensors for in vivo use.
    Pickup J
    Trends Biotechnol; 1993 Jul; 11(7):285-91. PubMed ID: 7763951
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man.
    Pickup JC; Claremont DJ; Shaw GW
    Acta Diabetol; 1993; 30(3):143-8. PubMed ID: 8111074
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans.
    Gilligan BC; Shults M; Rhodes RK; Jacobs PG; Brauker JH; Pintar TJ; Updike SJ
    Diabetes Technol Ther; 2004 Jun; 6(3):378-86. PubMed ID: 15198842
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasma.
    Kerner W; Kiwit M; Linke B; Keck FS; Zier H; Pfeiffer EF
    Biosens Bioelectron; 1993; 8(9-10):473-82. PubMed ID: 8311940
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Rapid detection of hyperglycaemia by a subcutaneously-implanted glucose sensor in the rat.
    Ward WK; Wilgus ES; Troupe JE
    Biosens Bioelectron; 1994; 9(6):423-8. PubMed ID: 7917181
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Continuous monitoring of glucose in subcutaneous tissue using microfabricated differential affinity sensors.
    Huang X; Leduc C; Ravussin Y; Li S; Davis E; Song B; Wang Q; Accili D; Leibel R; Lin Q
    J Diabetes Sci Technol; 2012 Nov; 6(6):1436-44. PubMed ID: 23294791
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration.
    Schmidtke DW; Heller A
    Anal Chem; 1998 May; 70(10):2149-55. PubMed ID: 9608851
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Tissue response to subcutaneous implantation of glucose-oxidase-based glucose sensors in rats.
    Henninger N; Woderer S; Kloetzer HM; Staib A; Gillen R; Li L; Yu X; Gretz N; Kraenzlin B; Pill J
    Biosens Bioelectron; 2007 Aug; 23(1):26-34. PubMed ID: 17467971
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Increased responses of glucagon and glucose production to hypoglycemia with intraperitoneal versus subcutaneous insulin treatment.
    Wan CK; Giacca A; Matsuhisa M; El-Bahrani B; Lam L; Rodgers C; Shi ZQ
    Metabolism; 2000 Aug; 49(8):984-9. PubMed ID: 10954014
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Towards implantable glucose sensors: a review.
    Wilkins ES
    J Biomed Eng; 1989 Sep; 11(5):354-61. PubMed ID: 2677522
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In-vivo behaviour of hypodermically implanted microfabricated glucose sensors.
    Koudelka M; Rohner-Jeanrenaud F; Terrettaz J; Bobbioni-Harsch E; de Rooij NF; Jeanrenaud B
    Biosens Bioelectron; 1991; 6(1):31-6. PubMed ID: 2049169
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A miniaturized Nafion-based glucose sensor: in vitro and in vivo evaluation in dogs.
    Moussy F; Harrison DJ; Rajotte RV
    Int J Artif Organs; 1994 Feb; 17(2):88-94. PubMed ID: 8039946
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring.
    Aussedat B; Dupire-Angel M; Gifford R; Klein JC; Wilson GS; Reach G
    Am J Physiol Endocrinol Metab; 2000 Apr; 278(4):E716-28. PubMed ID: 10751207
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer.
    Pickup JC; Shaw GW; Claremont DJ
    Diabetologia; 1989 Mar; 32(3):213-7. PubMed ID: 2666212
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation.
    Ward WK; Jansen LB; Anderson E; Reach G; Klein JC; Wilson GS
    Biosens Bioelectron; 2002 Mar; 17(3):181-9. PubMed ID: 11839471
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Polymeric "smart" coatings to prevent foreign body response to implantable biosensors.
    Wang Y; Papadimitrakopoulos F; Burgess DJ
    J Control Release; 2013 Aug; 169(3):341-7. PubMed ID: 23298616
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Problems associated with subcutaneously implanted glucose sensors.
    Gerritsen M
    Diabetes Care; 2000 Feb; 23(2):143-5. PubMed ID: 10868819
    [No Abstract]   [Full Text] [Related]  

  • 38. Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery.
    Piper HG; Alexander JL; Shukla A; Pigula F; Costello JM; Laussen PC; Jaksic T; Agus MS
    Pediatrics; 2006 Sep; 118(3):1176-84. PubMed ID: 16951013
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Glucagon response to hypoglycemia is improved by insulin-independent restoration of normoglycemia in diabetic rats.
    Shi ZQ; Rastogi KS; Lekas M; Efendic S; Drucker DJ; Vranic M
    Endocrinology; 1996 Aug; 137(8):3193-9. PubMed ID: 8754739
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor.
    Steil GM; Rebrin K; Mastrototaro J; Bernaba B; Saad MF
    Diabetes Technol Ther; 2003; 5(1):27-31. PubMed ID: 12725704
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.