These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Safety and efficiency of pulse charge multiplication for chronic ventricular output programming. Kindermann M; Kusch O; Fröhlig G; Markwirth T; Schwaab B; Schwerdt H Pacing Clin Electrophysiol; 2001 Apr; 24(4 Pt 1):430-40. PubMed ID: 11341079 [TBL] [Abstract][Full Text] [Related]
23. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity. Schwaab B; Fröhlig G; Schwerdt H; Heisel A; Berg M; Schieffer H Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 1):2055-63. PubMed ID: 9826856 [TBL] [Abstract][Full Text] [Related]
24. Benefits of smaller electrode surface area (4 mm2) on steroid-eluting leads. Schuchert A; Kuck KH Pacing Clin Electrophysiol; 1991 Dec; 14(12):2098-104. PubMed ID: 1723192 [TBL] [Abstract][Full Text] [Related]
25. The safety and efficacy of chronic ventricular pacing at 1.6 volts using a steroid eluting lead. Stamato NJ; O'Toole MF; Fetter JG; Enger EL Pacing Clin Electrophysiol; 1992 Mar; 15(3):248-51. PubMed ID: 1372716 [TBL] [Abstract][Full Text] [Related]
26. Sick sinus syndrome and diffuse impairment of the conduction system in a child: successful pacing with a steroid eluting endocardial pacing lead. Capucci A; Boriani G; Galli R; Picchio FM; Pierangeli A; Magnani B Pediatr Cardiol; 1992 Jan; 13(1):44-7. PubMed ID: 1736268 [TBL] [Abstract][Full Text] [Related]
28. Acute performance of steroid-eluting screw-in leads for atrial free wall pacing. Nakazato Y; Nakata Y; Mineta Y; Nakazato K; Yasuda M; Sumiyoshi M; Yamaguchi H Jpn Circ J; 1999 Jul; 63(7):514-6. PubMed ID: 10462016 [TBL] [Abstract][Full Text] [Related]
29. [Modern electrodes with and without steroid: effects on stimulation current of cardiac pacemakers]. Schuchert A; Kuck KH; Meinertz T Z Kardiol; 1995 Apr; 84(4):289-95. PubMed ID: 7785301 [TBL] [Abstract][Full Text] [Related]
30. [Local steroid elution via pacemaker electrodes: improved stimulation and sensing functions]. Schuchert A; Kuck KH Dtsch Med Wochenschr; 1992 Apr; 117(16):607-12. PubMed ID: 1568427 [TBL] [Abstract][Full Text] [Related]
31. Low chronic pacing thresholds of steroid-eluting active-fixation ventricular pacemaker leads: a useful alternative to passive-fixation leads. Hidden-Lucet F; Halimi F; Gallais Y; Petitot JC; Fontaine G; Frank R Pacing Clin Electrophysiol; 2000 Nov; 23(11 Pt 2):1798-800. PubMed ID: 11139927 [TBL] [Abstract][Full Text] [Related]
32. Five-year follow-up of a bipolar steroid-eluting ventricular pacing lead. Schwaab B; Fröhlig G; Berg M; Schwerdt H; Schieffer H Pacing Clin Electrophysiol; 1999 Aug; 22(8):1226-8. PubMed ID: 10461300 [TBL] [Abstract][Full Text] [Related]
33. Long-term follow-up of pacemakers with an Autocapture pacing system. Erdinler I; Akyol A; Okmen E; Oguz E; Gurkan K; Ulufer T Jpn Heart J; 2002 Nov; 43(6):631-41. PubMed ID: 12558127 [TBL] [Abstract][Full Text] [Related]
34. Clinical use of low output settings in 1.2-mm2 steroid eluting electrodes: three years of experience. Danilovic D; Ohm OJ; Breivik K Pacing Clin Electrophysiol; 1998 Dec; 21(12):2606-15. PubMed ID: 9894651 [TBL] [Abstract][Full Text] [Related]
35. A new efficient NanoTip lead. Stokes K; Bird T Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1901-5. PubMed ID: 1704564 [TBL] [Abstract][Full Text] [Related]
36. The "SPEM" (Studio Policentrico Elettrocateteri Membrane): a multicenter study on membrane leads. Rusconi L; Sigliano R; Mininno A Pacing Clin Electrophysiol; 1998 Oct; 21(10):1943-8. PubMed ID: 9793091 [TBL] [Abstract][Full Text] [Related]