BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

336 related articles for article (PubMed ID: 8291728)

  • 1. Efficacy of the self-inflating bulb in detecting esophageal intubation. Does the presence of a nasogastric tube or cuff deflation make a difference?
    Salem MR; Wafai Y; Joseph NJ; Baraka A; Czinn EA
    Anesthesiology; 1994 Jan; 80(1):42-8. PubMed ID: 8291728
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of the self-inflating bulb for detecting esophageal intubation after "esophageal ventilation".
    Salem MR; Wafai Y; Baraka A; Taimorrazy B; Joseph NJ; Nimmagadda U
    Anesth Analg; 1993 Dec; 77(6):1227-31. PubMed ID: 8250317
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese.
    Lang DJ; Wafai Y; Salem MR; Czinn EA; Halim AA; Baraka A
    Anesthesiology; 1996 Aug; 85(2):246-53. PubMed ID: 8712438
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effectiveness of the self-inflating bulb for verification of proper placement of the Esophageal Tracheal Combitube.
    Wafai Y; Salem MR; Baraka A; Joseph NJ; Czinn EA; Paulissian R
    Anesth Analg; 1995 Jan; 80(1):122-6. PubMed ID: 7802268
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The self-inflating bulb to detect esophageal intubation during emergency airway management.
    Kasper CL; Deem S
    Anesthesiology; 1998 Apr; 88(4):898-902. PubMed ID: 9579497
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy of the self-inflating bulb in differentiating esophageal from tracheal intubation in the parturient undergoing cesarean section.
    Baraka A; Khoury PJ; Siddik SS; Salem MR; Joseph NJ
    Anesth Analg; 1997 Mar; 84(3):533-7. PubMed ID: 9052296
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy and reliability of the self-inflating bulb to verify tracheal intubation in out-of-hospital cardiac arrest patients.
    Tanigawa K; Takeda T; Goto E; Tanaka K
    Anesthesiology; 2000 Dec; 93(6):1432-6. PubMed ID: 11149438
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The esophageal detector device. Does it work?
    Zaleski L; Abello D; Gold MI
    Anesthesiology; 1993 Aug; 79(2):244-7. PubMed ID: 8342836
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The self-inflating bulb as an airway adjunct: is it reliable in children weighing less than 20 kilograms?
    Sharieff GQ; Rodarte A; Wilton N; Bleyle D
    Acad Emerg Med; 2003 Apr; 10(4):303-8. PubMed ID: 12670841
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The self-inflating bulb as an esophageal detector device in children weighing more than twenty kilograms: a comparison of two techniques.
    Sharieff GQ; Rodarte A; Wilton N; Silva PD; Bleyle D
    Ann Emerg Med; 2003 May; 41(5):623-9. PubMed ID: 12712028
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The tracheal detecting-bulb: a new device to distinguish tracheal from esophageal intubation.
    Tong YL; Sun M; Tang WH; Xia JY
    Acta Anaesthesiol Sin; 2002 Dec; 40(4):159-63. PubMed ID: 12596613
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Verification of endotracheal tube placement using electrical stimulation through electrodes placed on the endotracheal tube cuff.
    Heo T; Lee SM; Kim HS; Choi SS; Jung YH; Lee DH; Cho YS; Lee BK; Jeung KW
    Acta Anaesthesiol Scand; 2016 Jul; 60(6):747-55. PubMed ID: 26846426
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of a new method to distinguish esophageal from tracheal intubation by measuring the endotracheal cuff pressure in a porcine model.
    Hsu CC; Lee WJ; Wu YL; Guo HR; Lin HJ
    Acad Emerg Med; 2005 Dec; 12(12):1153-7. PubMed ID: 16293896
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The esophageal detector device: a rapid and accurate method for assessing tracheal versus esophageal intubation in a porcine model.
    Foutch RG; Magelssen MD; MacMillan JG
    Ann Emerg Med; 1992 Sep; 21(9):1073-6. PubMed ID: 1514718
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Aspirated air capnography with esophageal detector device to confirm tracheal intubation in rapid sequence induction.
    Ghabash M; Choueiry P; Matta M
    Middle East J Anaesthesiol; 1998 Jun; 14(5):381-6. PubMed ID: 9785341
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a prototype esophageal detection device.
    Marley CD; Eitel DR; Anderson TE; Murn AJ; Patterson GA
    Acad Emerg Med; 1995 Jun; 2(6):503-7. PubMed ID: 7497050
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A simple technique for diagnosing oesophageal intubation.
    Kalpokas M; Russell WJ
    Anaesth Intensive Care; 1989 Feb; 17(1):39-43. PubMed ID: 2712274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Verification of endotracheal tube position.
    Salem MR
    Anesthesiol Clin North Am; 2001 Dec; 19(4):813-39. PubMed ID: 11778382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement.
    Werner SL; Smith CE; Goldstein JR; Jones RA; Cydulka RK
    Ann Emerg Med; 2007 Jan; 49(1):75-80. PubMed ID: 17014927
    [TBL] [Abstract][Full Text] [Related]  

  • 20. To characterize the incidence of airway misplacement of nasogastric tubes in anesthetized intubated patients by using a manometer technique.
    Hsieh SW; Chen HS; Chen YT; Hung KC
    J Clin Monit Comput; 2017 Apr; 31(2):443-448. PubMed ID: 26964993
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.