These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 8297194)

  • 1. The international normalized ratio. A guide to understanding and correcting its problems.
    Hirsh J; Poller L
    Arch Intern Med; 1994 Feb; 154(3):282-8. PubMed ID: 8297194
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of the international normalized ratio for monitoring the induction phase of warfarin: comparison with the prothrombin time ratio.
    Johnston M; Harrison L; Moffat K; Willan A; Hirsh J
    J Lab Clin Med; 1996 Aug; 128(2):214-7. PubMed ID: 8765218
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Potential dosing errors using portable prothrombin time monitoring devices.
    Loebstein R; Kurnik D; Lubetsky A; Ezra D; Halkin H
    Blood Coagul Fibrinolysis; 2003 Jul; 14(5):479-83. PubMed ID: 12851534
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).
    Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P
    Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Accuracy and reliability of international normalized ratio (INR) in monitoring of warfarin--comparison in the sensitivity to extrinsic coagulation factors between PT (INR) and TT (INR)].
    Sakayori T; Naito S; Yoshida M; Kumano O; Kato N; Okuda M; Ieko M
    Rinsho Byori; 2010 Aug; 58(8):779-85. PubMed ID: 20860170
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Oral anticoagulant monitoring by laboratory or near-patient testing: what a clinician should be aware of.
    Tripodi A; Breukink-Engbers WG; van den Besselaar AM
    Semin Vasc Med; 2003 Aug; 3(3):243-54. PubMed ID: 15199457
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Suboptimal Anticoagulant Management in Japanese Patients with Nonvalvular Atrial Fibrillation Receiving Warfarin for Stroke Prevention.
    Hirano T; Kaneko H; Mishina S; Wang F; Morita S
    J Stroke Cerebrovasc Dis; 2017 Oct; 26(10):2102-2110. PubMed ID: 28532651
    [TBL] [Abstract][Full Text] [Related]  

  • 8. International Normalized Ratio (INR): an improved way to monitor oral anticoagulant therapy.
    Oertel LB
    Nurse Pract; 1995 Sep; 20(9):15-6, 21-2. PubMed ID: 7501312
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Anti-Xa and anti-IIa drugs alter international normalized ratio measurements: potential problems in the monitoring of oral anticoagulants.
    Tobu M; Iqbal O; Hoppensteadt D; Neville B; Messmore HL; Fareed J
    Clin Appl Thromb Hemost; 2004 Oct; 10(4):301-9. PubMed ID: 15497016
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of two methods for INR determination in a pharmacist-based oral anticoagulation clinic.
    Yamreudeewong W; Johnson JV; Cassidy TG; Berg JT
    Pharmacotherapy; 1996; 16(6):1159-65. PubMed ID: 8947990
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of home prothrombin international ratio (PT-INR) management in children with mechanical prosthetic valves - Importance of individual correlations between laboratory and CoaguChek device PT-INRs.
    Ino N; Masutani S; Tanikawa S; Iwamoto Y; Saiki H; Ishido H; Tamura M; Senzaki H
    J Cardiol; 2018 Feb; 71(2):187-191. PubMed ID: 29066099
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reemergence of the International Normalized Ratio for the standardization of prothrombin time.
    Morse EE; Panek S; Pisciotto P; Kiraly T; Bona R; Vose K; Rickles F
    Ann Clin Lab Sci; 1993; 23(3):184-8. PubMed ID: 8323252
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The application of thrombin generation tests to warfarin anticoagulation monitoring].
    Chen HY; Ding QL; Zhang LW; Xu GQ; Dai J; Wang XF; Xi XD; Wang HL
    Zhonghua Xue Ye Xue Za Zhi; 2008 Mar; 29(3):168-70. PubMed ID: 18788615
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Contribution of rivaroxaban to the international normalized ratio when switching to warfarin for anticoagulation as determined by simulation studies.
    Siegmund HU; Burghaus R; Kubitza D; Coboeken K
    Br J Clin Pharmacol; 2015 Jun; 79(6):959-66. PubMed ID: 25510952
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of warfarin management with international normalized ratio self-testing and online remote monitoring and management plus low-dose vitamin k with genomic considerations: a pilot study.
    Bussey HI; Bussey M; Bussey-Smith KL; Frei CR
    Pharmacotherapy; 2013 Nov; 33(11):1136-46. PubMed ID: 24038412
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Anticoagulation monitoring part 1: warfarin and parenteral direct thrombin inhibitors.
    Spinler SA; Nutescu EA; Smythe MA; Wittkowsky AK
    Ann Pharmacother; 2005 Jun; 39(6):1049-55. PubMed ID: 15855245
    [TBL] [Abstract][Full Text] [Related]  

  • 17. D-Dimer versus International Normalized Ratio of Prothrombin Time in Ischemic Stroke Patients Treated with Sufficient Warfarin.
    Yamamoto R; Nakae Y; Tanaka F; Johkura K
    J Stroke Cerebrovasc Dis; 2016 Jul; 25(7):1781-1785. PubMed ID: 27103270
    [TBL] [Abstract][Full Text] [Related]  

  • 18. International standardization of laboratory control of oral anticoagulant therapy: a survey of thromboplastin reagents used for prothrombin time testing.
    van den Besselaar AM
    J Heart Valve Dis; 1993 Jan; 2(1):42-52. PubMed ID: 8269109
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of three loading doses of warfarin on the international normalized ratio for dogs.
    Monnet E; Morgan MR
    Am J Vet Res; 2000 Jan; 61(1):48-50. PubMed ID: 10630777
    [TBL] [Abstract][Full Text] [Related]  

  • 20. How to Generate a More Accurate Laboratory-Based International Normalized Ratio: Solutions to Obtaining or Verifying the Mean Normal Prothrombin Time and International Sensitivity Index.
    Favaloro EJ
    Semin Thromb Hemost; 2019 Feb; 45(1):10-21. PubMed ID: 30134448
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.