BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 8299202)

  • 21. Immunoassay labels based on chemiluminescence and bioluminescence.
    Seitz WR
    Clin Biochem; 1984 Apr; 17(2):120-5. PubMed ID: 6375893
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Ultrasensitive detection of prostate-specific antigen by a time-resolved immunofluorometric assay and the Immulite immunochemiluminescent third-generation assay: potential applications in prostate and breast cancers.
    Ferguson RA; Yu H; Kalyvas M; Zammit S; Diamandis EP
    Clin Chem; 1996 May; 42(5):675-84. PubMed ID: 8653891
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Novel signal-enhancing immunoassay for ultrasensitive biomarker detection based on laser-induced fluorescence.
    Zhang J; Wang S; Liu K; Wei Y; Wang X; Duan Y
    Anal Chem; 2015 Mar; 87(5):2959-65. PubMed ID: 25655002
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Development and applications of ultrasensitive enzyme immunoassays for antigens and antibodies.
    Ishikawa E; Hashida S; Tanaka K; Kohno T
    Clin Chim Acta; 1989 Dec; 185(3):223-30. PubMed ID: 2695272
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Fluorescent Biosensors Based on Single-Molecule Counting.
    Ma F; Li Y; Tang B; Zhang CY
    Acc Chem Res; 2016 Sep; 49(9):1722-30. PubMed ID: 27583695
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Time-resolved fluorescence detection of enzyme-amplified lanthanide luminescence for nucleic acid hybridization assays.
    Templeton EF; Wong HE; Evangelista RA; Granger T; Pollak A
    Clin Chem; 1991 Sep; 37(9):1506-12. PubMed ID: 1893576
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Part-per-trillion level detection of estradiol by competitive fluorescence immunoassay using DNA/dye conjugate as antibody multiple labels.
    Zhu S; Zhang Q; Guo LH
    Anal Chim Acta; 2008 Aug; 624(1):141-6. PubMed ID: 18706319
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Chemiluminescent labels for steroid immunoassays.
    Klingler W; Wiegand G; Knuppen R
    J Steroid Biochem; 1987; 27(1-3):41-5. PubMed ID: 3121923
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of four distinct detection platforms using multiple ligand binding assay formats.
    Soderstrom CI; Spriggs FP; Song W; Burrell S
    J Immunol Methods; 2011 Aug; 371(1-2):106-13. PubMed ID: 21749873
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An ultrasensitive electrogenerated chemiluminescence-based immunoassay for specific detection of Zika virus.
    Acharya D; Bastola P; Le L; Paul AM; Fernandez E; Diamond MS; Miao W; Bai F
    Sci Rep; 2016 Aug; 6():32227. PubMed ID: 27554037
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Chemiluminescence: a new end-point for clinical assays.
    Bronstein I; Kricka LJ
    Clin Lab Manage Rev; 1990; 4(4):303-5. PubMed ID: 10105862
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Bioconjugation of Antibodies and Enzyme Labels onto Magnetic Beads.
    Otieno BA; Krause CE; Rusling JF
    Methods Enzymol; 2016; 571():135-50. PubMed ID: 27112398
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Enzyme-amplified lanthanide luminescence for enzyme detection in bioanalytical assays.
    Evangelista RA; Pollak A; Templeton EF
    Anal Biochem; 1991 Aug; 197(1):213-24. PubMed ID: 1952068
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bioluminescence immunoassay for cortisol using recombinant aequorin as a label.
    Mirasoli M; Deo SK; Lewis JC; Roda A; Daunert S
    Anal Biochem; 2002 Jul; 306(2):204-11. PubMed ID: 12123657
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cross-method comparison of serum androstenedione measurement with respect to the validation of a new fully automated chemiluminescence immunoassay.
    van Helden J; Weiskirchen R
    Clin Biochem; 2018 Dec; 62():32-38. PubMed ID: 30261182
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Luminometry: a novel bioluminescent immunoassay enhances the quantitation of mucosal and systemic antibody responses.
    Jackson RJ; Fujihashi K; Kiyono H; McGhee JR
    J Immunol Methods; 1996 Apr; 190(2):189-97. PubMed ID: 8621954
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A luminescent label for the immunoassay of oxytocin.
    Lequin RM; Moss RJ; van Nispen JW
    J Immunoassay; 1986; 7(3):169-79. PubMed ID: 3745445
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dioxetane-doped silica nanoparticles as ultrasensitive reagentless thermochemiluminescent labels for bioanalytics.
    Roda A; Di Fusco M; Quintavalla A; Guardigli M; Mirasoli M; Lombardo M; Trombini C
    Anal Chem; 2012 Nov; 84(22):9913-9. PubMed ID: 23121217
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Chemiluminescent assay of alkaline phosphatase applied in an ultrasensitive enzyme immunoassay of thyrotropin.
    Bronstein I; Voyta JC; Thorpe GH; Kricka LJ; Armstrong G
    Clin Chem; 1989 Jul; 35(7):1441-6. PubMed ID: 2667800
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Enzyme-free chemiluminescence immunoassay for the determination of thyroid stimulating hormone.
    Shim C; Chong R; Lee JH
    Talanta; 2017 Aug; 171():229-235. PubMed ID: 28551133
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.