152 related articles for article (PubMed ID: 830215)
1. Temporary inhibition of permanently implanted demand pacemakers.
Latif P; Ewy GA
Circulation; 1977 Jan; 55(1):27-31. PubMed ID: 830215
[TBL] [Abstract][Full Text] [Related]
2. Electromagnetic interference with pacemakers caused by portable media players.
Thaker JP; Patel MB; Jongnarangsin K; Liepa VV; Thakur RK
Heart Rhythm; 2008 Apr; 5(4):538-44. PubMed ID: 18329961
[TBL] [Abstract][Full Text] [Related]
3. Fluoroscope-generated electromagnetic interference in an external demand pacemaker: report of a case.
Leeds CJ; Akhtar M; Damato AN
Circulation; 1977 Mar; 55(3):548-50. PubMed ID: 837492
[TBL] [Abstract][Full Text] [Related]
4. Myopotential inhibition of unipolar QRS-inhibited (VVI) pacemakers, assessed by ambulatory Holter monitoring of the electrocardiogram.
Breivik K; Ohm OJ
Pacing Clin Electrophysiol; 1980 Jul; 3(4):470-8. PubMed ID: 6160541
[TBL] [Abstract][Full Text] [Related]
5. Notes on ventricular tachycardia occurring during magnet waving and on the function of the Omni-Ectocor pacemaker.
van Cleve RB; Sung RJ; Maytin O; Castellanos A
Eur J Cardiol; 1978 Nov; 8(4-5):543-51. PubMed ID: 720371
[TBL] [Abstract][Full Text] [Related]
6. Pacemaker endless loop tachycardia: termination by simple techniques other than magnet application.
Barold SS; Falkoff MD; Ong LS; Heinle RA
Am J Med; 1988 Dec; 85(6):817-22. PubMed ID: 3195605
[TBL] [Abstract][Full Text] [Related]
7. Interference of cellular phones with implanted permanent pacemakers.
Chen WH; Lau CP; Leung SK; Ho DS; Lee IS
Clin Cardiol; 1996 Nov; 19(11):881-6. PubMed ID: 8914782
[TBL] [Abstract][Full Text] [Related]
8. Device management of arrhythmias after Fontan conversion.
Tsao S; Deal BJ; Backer CL; Ward K; Franklin WH; Mavroudis C
J Thorac Cardiovasc Surg; 2009 Oct; 138(4):937-40. PubMed ID: 19660377
[TBL] [Abstract][Full Text] [Related]
9. Lack of sensing by demand pacemakers due to intraventricular conduction defects.
Vera Z; Mason DT; Awan NA; Hiliard G; Massumi RA
Circulation; 1975 May; 51(5):815-22. PubMed ID: 47273
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of implanted faulty demand pacemakers by magnet waving and electrical chest wall stimulation. A report of clinical experience.
Thormann J; Schwarz F; Ensslen R
Eur J Cardiol; 1977 Mar; 5(2):139-54. PubMed ID: 852492
[TBL] [Abstract][Full Text] [Related]
11. Atrial pacing from the coronary vein. Ten-year experience in 50 patients with implanted pervenous pacemakers.
Moss AJ; Rivers RJ
Circulation; 1978 Jan; 57(1):103-6. PubMed ID: 618375
[TBL] [Abstract][Full Text] [Related]
12. Chest wall stimulation in evaluation of patients with implanted ventricular-inhibited demand pacemakers.
Barold SS; Pupillo GA; Gaidula JJ; Linhart JW
Br Heart J; 1970 Nov; 32(6):783-9. PubMed ID: 5212353
[TBL] [Abstract][Full Text] [Related]
13. Interference by cellular phones with permanent implanted pacemakers: an update.
Hekmat K; Salemink B; Lauterbach G; Schwinger RH; Südkamp M; Weber HJ; Mehlhorn U
Europace; 2004 Jul; 6(4):363-9. PubMed ID: 15172661
[TBL] [Abstract][Full Text] [Related]
14. The influence of elevated 50 Hz electric and magnetic fields on implanted cardiac pacemakers: the role of the lead configuration and programming of the sensitivity.
Toivonen L; Valjus J; Hongisto M; Metso R
Pacing Clin Electrophysiol; 1991 Dec; 14(12):2114-22. PubMed ID: 1723194
[TBL] [Abstract][Full Text] [Related]
15. Unmasking of slow intrinsic ventricular excitation by magnetic inhibition of R-wave inhibited demand pacemakers.
Voukydis PC; Shulman AN; Cohen SI
Chest; 1975 Mar; 67(3):304-7. PubMed ID: 1112124
[TBL] [Abstract][Full Text] [Related]
16. Phantom pacemaker programming.
Fieldman A; Dobrow RJ
Pacing Clin Electrophysiol; 1978 Apr; 1(2):166-71. PubMed ID: 83629
[TBL] [Abstract][Full Text] [Related]
17. [Incomplete lead fracture as a cause of bradyarrhythmia in patients with artificial pacemakers (author's transl)].
Beyer J; Schaudig A; Stemple G; Zimmermann M
Herz; 1978 Dec; 63(36):362-6. PubMed ID: 554857
[TBL] [Abstract][Full Text] [Related]
18. Apparent malfunction of demand pacemakers due to spurious potentials generated by contact between two endocardial electrodes.
Waxman HL; Lazzara R; El-Sherif N
Pacing Clin Electrophysiol; 1978 Oct; 1(4):531-4. PubMed ID: 95648
[TBL] [Abstract][Full Text] [Related]
19. Mode of operation induced by rapid external chest wall stimulation in patients with normally functioning QRS-inhibited (VVI) pacemakers.
Castellanos A; Bloom MG; Sung RJ; Rozanski JJ; Myerburg RJ
Pacing Clin Electrophysiol; 1979 Jan; 2(1):2-10. PubMed ID: 95261
[TBL] [Abstract][Full Text] [Related]
20. Utility and safety of temporary pacing using active fixation leads and externalized re-usable permanent pacemakers after lead extraction.
Kawata H; Pretorius V; Phan H; Mulpuru S; Gadiyaram V; Patel J; Steltzner D; Krummen D; Feld G; Birgersdotter-Green U
Europace; 2013 Sep; 15(9):1287-91. PubMed ID: 23482613
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]