These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 8307723)

  • 21. Percutaneous closure of the small patent ductus arteriosus using occluding spring coils.
    Moore JW; George L; Kirkpatrick SE; Mathewson JW; Spicer RL; Uzark K; Rothman A; Cambier PA; Slack MC; Kirby WC
    J Am Coll Cardiol; 1994 Mar; 23(3):759-65. PubMed ID: 8113562
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Morphological changes in patent ductus arteriosus after endovascular occlusion (clinico-experimental study)].
    Prokubovskiĭ VI; Stupin IV; Savel'ev SV; Tsareva LA; Verin Ve
    Grud Serdechnososudistaia Khir; 1991 Aug; (8):42-6. PubMed ID: 1751055
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Closure of a persistent ductus arteriosus of Botallo in two dogs using transarterial coil embolization].
    Glaus TM; Gardelle O; Bass M; Kiowski WK
    Schweiz Arch Tierheilkd; 1999; 141(4):191-4. PubMed ID: 10228398
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The snare-assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: immediate and intermediate results.
    Ing FF; Sommer RJ
    J Am Coll Cardiol; 1999 May; 33(6):1710-8. PubMed ID: 10334447
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Early reopening and recanalization after successful coil occlusion of the patent ductus arteriosus.
    Turner DR; Forbes TJ; Epstein ML; Vincent JA
    Am Heart J; 2002 May; 143(5):889-93. PubMed ID: 12040354
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Experimental evaluation of a modified Amplatzer duct occluder.
    Kong H; Gu X; Bass JL; Titus J; Urness M; Kim TH; Hunter DW
    Catheter Cardiovasc Interv; 2001 Aug; 53(4):571-6. PubMed ID: 11515016
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A novel endovascular occlusion device with a steerable introducer for embolization in a porcine model.
    Lu W; Fu W; Si Y; Chen X; Cai Q; Xiong Y; Hong S; Yang D
    Catheter Cardiovasc Interv; 2016 Feb; 87(3):E86-96. PubMed ID: 26651031
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The Amplatzer duct occluder: experience in 209 patients.
    Bilkis AA; Alwi M; Hasri S; Haifa AL; Geetha K; Rehman MA; Hasanah I
    J Am Coll Cardiol; 2001 Jan; 37(1):258-61. PubMed ID: 11153748
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Use of a balloon occlusion catheter to facilitate transarterial coil embolisation of a patent ductus arteriosus in two dogs.
    Saunders JH; Snaps FR; Peeters D; Trotteur G; Dondelinger RF
    Vet Rec; 1999 Nov; 145(19):544-6. PubMed ID: 10609571
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Initial clinical experience with the Medtronic Micro Vascular Plug™ in transcatheter occlusion of PDAs in extremely premature infants.
    Sathanandam S; Justino H; Waller BR; Radtke W; Qureshi AM
    Catheter Cardiovasc Interv; 2017 May; 89(6):1051-1058. PubMed ID: 27888552
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Delayed embolization of an Amplatz(®) canine duct occluder in a dog.
    Carlson JA; Achen SA; Saunders AB; Gordon SG; Miller MW
    J Vet Cardiol; 2013 Dec; 15(4):271-6. PubMed ID: 24246437
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Inadvertent stenting of patent ductus arteriosus with Amplatzer Vascular Plug.
    Javois AJ; Husayni TS; Thoele D; Van Bergen AH
    Catheter Cardiovasc Interv; 2006 Mar; 67(3):485-9. PubMed ID: 16475172
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Covidien micro vascular plug in congenital heart diseases and vascular anomalies: A new kid on the block for premature babies and older patients.
    Boudjemline Y
    Catheter Cardiovasc Interv; 2017 Jan; 89(1):114-119. PubMed ID: 27392516
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Transcatheter coil occlusion of persistent ductus arteriosus using detachable steel coils: short-term results.
    Arora R; Verma PK; Trehan V; Passey R; Nigam M; Kalra GS
    Indian Heart J; 1997; 49(1):60-4. PubMed ID: 9130427
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transcatheter occlusion of patent ductus arteriosus in adults.
    Schenck MH; O'Laughlin MP; Rokey R; Ludomirsky A; Mullins CE
    Am J Cardiol; 1993 Sep; 72(7):591-5. PubMed ID: 8362776
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcatheter closure in 354 pediatric cases of patent ductus arteriosus using five different devices.
    Zhang Z; Qian M; Wang H; Li Y
    Chin Med J (Engl); 2001 May; 114(5):456-8. PubMed ID: 11780402
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental evaluation of a new articulated Amplatzer ductal occluder device without fabric.
    Gruenstein DH; Bass JL
    Catheter Cardiovasc Interv; 2009 Sep; 74(3):482-7. PubMed ID: 19405162
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Use of simultaneous fluoroscopic and echocardiographic guidance during transarterial coil placement for embolization of patent ductus arteriosus in dogs.
    Szatmári V; Stokhof AA
    J Am Vet Med Assoc; 2006 Mar; 228(6):881-4. PubMed ID: 16536698
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of a novel endoluminal vascular occlusion device in a porcine model: early and late follow-up.
    Kipshidze N; Sadzaglishvili K; Panarella M; Rivera EA; Virmani R; Leon MB
    J Endovasc Ther; 2005 Aug; 12(4):486-94. PubMed ID: 16048381
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device.
    Rao PS; Kim SH; Choi JY; Rey C; Haddad J; Marcon F; Walsh K; Sideris EB
    J Am Coll Cardiol; 1999 Mar; 33(3):820-6. PubMed ID: 10080487
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.