These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 8309448)
1. Matching the 6-MV photon beam characteristics of two dissimilar linear accelerators. Marshall MG Med Phys; 1993; 20(6):1743-6. PubMed ID: 8309448 [TBL] [Abstract][Full Text] [Related]
2. Commissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators. Beyer GP J Appl Clin Med Phys; 2013 Jan; 14(1):4077. PubMed ID: 23318395 [TBL] [Abstract][Full Text] [Related]
3. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter. Almberg SS; Frengen J; Lindmo T Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444 [TBL] [Abstract][Full Text] [Related]
5. Properties of the 18-MV photon beam from a dual energy linear accelerator. Johnson DA; Ikoro NC; Chang CH; Scarbrough EC; Antich PP Med Phys; 1987; 14(6):1071-8. PubMed ID: 3696074 [TBL] [Abstract][Full Text] [Related]
6. Photon spectral characteristics of dissimilar 6 MV linear accelerators. Hinson WH; Kearns WT; deGuzman AF; Bourland JD Med Phys; 2008 May; 35(5):1698-702. PubMed ID: 18561644 [TBL] [Abstract][Full Text] [Related]
7. Dosimetric characteristics of unflattened 6 MV photon beams of a clinical linear accelerator: a Monte Carlo study. Mesbahi A Appl Radiat Isot; 2007 Sep; 65(9):1029-36. PubMed ID: 17616465 [TBL] [Abstract][Full Text] [Related]
8. Evidence for a significantly higher than expected depth dependence of wedge transmission factors on the 4 MV beam of a new dual energy accelerator. Biggs PJ; Beatty J; Radloff J Med Phys; 1998 Nov; 25(11):2234-6. PubMed ID: 9829251 [TBL] [Abstract][Full Text] [Related]
9. Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from varian clinac 2100 series linear accelerators. Cho SH; Vassiliev ON; Lee S; Liu HH; Ibbott GS; Mohan R Med Phys; 2005 Jan; 32(1):137-48. PubMed ID: 15719964 [TBL] [Abstract][Full Text] [Related]
10. Dosimetric parameters of a modified set of wedges for use with asymmetric fields of a 6 MV linear accelerator. Niroomand-Rad A; Rodgers JE; Taylor P; Hames B Med Phys; 1994 Sep; 21(9):1405-8. PubMed ID: 7838051 [TBL] [Abstract][Full Text] [Related]
11. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator. Tsechanski A; Krutman Y; Faermann S Phys Med Biol; 2005 Dec; 50(23):5629-39. PubMed ID: 16306657 [TBL] [Abstract][Full Text] [Related]
12. Characteristics of the 6-MV photon beam produced by a dual energy linear accelerator. Ikoro NC; Johnson DA; Antich PP Med Phys; 1987; 14(1):93-7. PubMed ID: 3104744 [TBL] [Abstract][Full Text] [Related]
13. Dosimetric characterization of the 18-MV photon beam from the Siemens Mevatron 77 linear accelerator. Palta JR; Meyer JA; Hogstrom KR Med Phys; 1984; 11(5):717-24. PubMed ID: 6438461 [TBL] [Abstract][Full Text] [Related]
14. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines. Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of a photon and an electron beam of a 6-MV linear accelerator. Sharma SC; Modur P; Basavatia R Med Phys; 1988; 15(4):525-9. PubMed ID: 3211045 [TBL] [Abstract][Full Text] [Related]
16. Monte Carlo study of photon fields from a flattening filter-free clinical accelerator. Vassiliev ON; Titt U; Kry SF; Pönisch F; Gillin MT; Mohan R Med Phys; 2006 Apr; 33(4):820-7. PubMed ID: 16696457 [TBL] [Abstract][Full Text] [Related]
17. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams. Dalaryd M; Knöös T; Ceberg C Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630 [TBL] [Abstract][Full Text] [Related]
18. Dosimetric aspects of the therapeutic photon beams from a dual-energy linear accelerator. Al-Ghazi MS; Arjune B; Fiedler JA; Sharma PD Med Phys; 1988; 15(2):250-7. PubMed ID: 3386599 [TBL] [Abstract][Full Text] [Related]
19. A beam-matching concept for medical linear accelerators. Sjöström D; Bjelkengren U; Ottosson W; Behrens CF Acta Oncol; 2009; 48(2):192-200. PubMed ID: 18752079 [TBL] [Abstract][Full Text] [Related]
20. Dosimetric characteristics of wedges mounted beyond the blocking tray. Ochran TG; Boyer AL; Nyerick CE; Otte VA Med Phys; 1992; 19(1):187-94. PubMed ID: 1620046 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]