These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 8318346)

  • 41. Diagnosis of recurrent brain tumor: value of 201Tl SPECT vs 18F-fluorodeoxyglucose PET.
    Kahn D; Follett KA; Bushnell DL; Nathan MA; Piper JG; Madsen M; Kirchner PT
    AJR Am J Roentgenol; 1994 Dec; 163(6):1459-65. PubMed ID: 7992747
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Correlation of thallium-201 single photon emission computed tomography and survival after treatment failure in patients with glioblastoma multiforme.
    Vertosick FT; Selker RG; Grossman SJ; Joyce JM
    Neurosurgery; 1994 Mar; 34(3):396-401. PubMed ID: 8190213
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Identification and viability assessment of infarcted myocardium with late enhancement multidetector computed tomography: comparison with thallium single photon emission computed tomography and echocardiography.
    Chiou KR; Liu CP; Peng NJ; Huang WC; Hsiao SH; Huang YL; Chen KH; Wu MT
    Am Heart J; 2008 Apr; 155(4):738-45. PubMed ID: 18371485
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction.
    Sakamoto H; Kondo M; Motohiro M; Usami S
    Jpn Circ J; 2001 Dec; 65(12):1017-21. PubMed ID: 11767991
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Detection of esophageal carcinoma using single-photon emission computed tomography of thallium-201: a preliminary report.
    Sun SS; Shih CS; Hsu NY; Teng SC; Kao CH
    Anticancer Res; 2001; 21(6A):4109-12. PubMed ID: 11911302
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Detection of recurrent nasopharyngeal carcinomas with technetium-99m methoxyisobutylisonitrile single photon emission computed tomography in patients with indeterminate magnetic resonance imaging findings after radiotherapy.
    Tsai MH; Shiau YC; Tai CJ; Lin CC; Lee CC; Kao A
    Ann Otol Rhinol Laryngol; 2003 May; 112(5):415-8. PubMed ID: 12784979
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Clinical significance of thallium-201 single-photon emission computerized tomography (Tl-201 SPECT) in the evaluation of viability of gliomas.
    Taguchi A
    Kurume Med J; 1992; 39(4):267-78. PubMed ID: 1305909
    [TBL] [Abstract][Full Text] [Related]  

  • 48. (201)Tl-SPECT in low-grade gliomas: diagnostic accuracy in differential diagnosis between tumour recurrence and radionecrosis.
    Gómez-Río M; Martínez Del Valle Torres D; Rodríguez-Fernández A; Llamas-Elvira JM; Lozano SO; Font CR; López Ramírez E; Katati M
    Eur J Nucl Med Mol Imaging; 2004 Sep; 31(9):1237-43. PubMed ID: 15133633
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Semiquantitative analysis using thallium-201 SPECT for differential diagnosis between tumor recurrence and radiation necrosis after gamma knife surgery for malignant brain tumors.
    Matsunaga S; Shuto T; Takase H; Ohtake M; Tomura N; Tanaka T; Sonoda M
    Int J Radiat Oncol Biol Phys; 2013 Jan; 85(1):47-52. PubMed ID: 22541963
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Thallium imaging for brain tumors with results measured by a semiquantitative index and correlated with histopathology.
    Slizofski WJ; Krishna L; Katsetos CD; Black P; Miyamoto C; Brown SJ; Vender J; Chevres A; Khan AS; McEwan J
    Cancer; 1994 Dec; 74(12):3190-7. PubMed ID: 7982182
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Detection of bladder cancer using single-photon emission computed tomography of thallium-201: a preliminary report.
    Yang CC; Shiau YC; Sun SS; Kao CH
    Anticancer Res; 2003; 23(3C):2977-80. PubMed ID: 12926148
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Use of 201Thallium brain SPECT, image registration, and semi-quantitative analysis in the follow-up of brain tumors.
    Rubinstein R; Karger H; Pietrzyk U; Siegal T; Gomori JM; Chisin R
    Eur J Radiol; 1996 Feb; 21(3):188-95. PubMed ID: 8777909
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Assessment of myocardial viability in patients with previous myocardial infarction by using single-photon emission computed tomography with a new metabolic tracer: [123I]-16-iodo-3-methylhexadecanoic acid (MIHA). Comparison with the rest-reinjection thallium-201 technique.
    Marie PY; Angioï M; Danchin N; Olivier P; Virion JM; Grentzinger A; Karcher G; Juillière Y; Fagret D; Cherrier F; Bertrand A
    J Am Coll Cardiol; 1997 Nov; 30(5):1241-8. PubMed ID: 9350922
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Preliminary Tl-201 SPECT for assessment of treatment efficacy in three patients with pancreatic cancer.
    Suga K; Fujita T; Nakada T; Yoneshiro S; Uchisako H; Nishigauchi K; Nakanishi T; Hamada Y
    Clin Nucl Med; 1993 Sep; 18(9):771-5. PubMed ID: 8403722
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Enhanced diagnosis of coronary artery disease in women by dobutamine thallium-201 ST-segment/heart rate slope and thallium-201 myocardial SPECT.
    Yeih DF; Huang PJ; Ho YL
    J Formos Med Assoc; 2007 Oct; 106(10):832-9. PubMed ID: 17964962
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The role of thallium-201 whole body scan with pelvic SPECT in patients with uterine cervical cancer treated by radiation therapy: a preliminary report.
    Liang JA; Kao CH; Chen SW; Yang SN; Sun SS
    Ann Nucl Med; 2003 Oct; 17(7):613-7. PubMed ID: 14651365
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Diagnostic accuracy of 201Thallium-SPECT and 18F-FDG-PET in the clinical assessment of glioma recurrence.
    Gómez-Río M; Rodríguez-Fernández A; Ramos-Font C; López-Ramírez E; Llamas-Elvira JM
    Eur J Nucl Med Mol Imaging; 2008 May; 35(5):966-75. PubMed ID: 18172642
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Early detection of X-ray CT negative recurrent lung cancer with Tl-201 SPECT.
    Kinuya S; Takahashi S; Takanaka T; Yokogawa A; Tubota S; Toufuku Y; Tonami N
    Clin Nucl Med; 1997 Mar; 22(3):196-7. PubMed ID: 9067683
    [No Abstract]   [Full Text] [Related]  

  • 59. [Value of (99)Tc(m)-MDP SPECT/CT in clinical decision-making for nasopharyngeal carcinoma and a comparison of the values of different imaging techniques for diagnosing skull-base bone invasion].
    Li W; Zhang RS; Zhang LQ; Lu BG; Fu WH
    Zhonghua Zhong Liu Za Zhi; 2017 Feb; 39(2):133-137. PubMed ID: 28219209
    [No Abstract]   [Full Text] [Related]  

  • 60. Dual isotope SPECT in the evaluation of recurrent brain tumor.
    Zhang JJ; Park CH; Kim SM; Ayyangar KM; Haghbin M
    Clin Nucl Med; 1992 Aug; 17(8):663-4. PubMed ID: 1505133
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.