170 related articles for article (PubMed ID: 8319965)
1. High-resolution EEG using spline generated surface Laplacians on spherical and ellipsoidal surfaces.
Law SK; Nunez PL; Wijesinghe RS
IEEE Trans Biomed Eng; 1993 Feb; 40(2):145-53. PubMed ID: 8319965
[TBL] [Abstract][Full Text] [Related]
2. Spatial filtering and neocortical dynamics: estimates of EEG coherence.
Srinivasan R; Nunez PL; Silberstein RB
IEEE Trans Biomed Eng; 1998 Jul; 45(7):814-26. PubMed ID: 9644890
[TBL] [Abstract][Full Text] [Related]
3. The spline-Laplacian in clinical neurophysiology: a method to improve EEG spatial resolution.
Nunez PL; Pilgreen KL
J Clin Neurophysiol; 1991 Oct; 8(4):397-413. PubMed ID: 1761706
[TBL] [Abstract][Full Text] [Related]
4. Spatial enhancement of EEG traces by surface Laplacian estimation: comparison between local and global methods.
Tandonnet C; Burle B; Hasbroucq T; Vidal F
Clin Neurophysiol; 2005 Jan; 116(1):18-24. PubMed ID: 15589178
[TBL] [Abstract][Full Text] [Related]
5. EEG and MEG coherence: measures of functional connectivity at distinct spatial scales of neocortical dynamics.
Srinivasan R; Winter WR; Ding J; Nunez PL
J Neurosci Methods; 2007 Oct; 166(1):41-52. PubMed ID: 17698205
[TBL] [Abstract][Full Text] [Related]
6. Regional head tissue conductivity estimation for improved EEG analysis.
Ferree TC; Eriksen KJ; Tucker DM
IEEE Trans Biomed Eng; 2000 Dec; 47(12):1584-92. PubMed ID: 11125593
[TBL] [Abstract][Full Text] [Related]
7. Improvement of spatial selectivity and decrease of mutual information of tri-polar concentric ring electrodes.
Koka K; Besio WG
J Neurosci Methods; 2007 Sep; 165(2):216-22. PubMed ID: 17681379
[TBL] [Abstract][Full Text] [Related]
8. Spherical splines and average referencing in scalp electroencephalography.
Ferree TC
Brain Topogr; 2006; 19(1-2):43-52. PubMed ID: 17019635
[TBL] [Abstract][Full Text] [Related]
9. Estimation of the effective and functional human cortical connectivity with structural equation modeling and directed transfer function applied to high-resolution EEG.
Astolfi L; Cincotti F; Mattia D; Salinari S; Babiloni C; Basilisco A; Rossini PM; Ding L; Ni Y; He B; Marciani MG; Babiloni F
Magn Reson Imaging; 2004 Dec; 22(10):1457-70. PubMed ID: 15707795
[TBL] [Abstract][Full Text] [Related]
10. Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull.
Ryynänen OR; Hyttinen JA; Malmivuo JA
IEEE Trans Biomed Eng; 2006 Sep; 53(9):1851-8. PubMed ID: 16941841
[TBL] [Abstract][Full Text] [Related]
11. Principal components analysis of Laplacian waveforms as a generic method for identifying ERP generator patterns: II. Adequacy of low-density estimates.
Kayser J; Tenke CE
Clin Neurophysiol; 2006 Feb; 117(2):369-80. PubMed ID: 16356768
[TBL] [Abstract][Full Text] [Related]
12. Cortical imaging on a head template: a simulation study using a resistor mesh model (RMM).
Chauveau N; Franceries X; Aubry F; Celsis P; Rigaud B
Brain Topogr; 2008 Sep; 21(1):52-60. PubMed ID: 18629625
[TBL] [Abstract][Full Text] [Related]
13. A visual study of surface potentials and Laplacians due to distributed neocortical sources: computer simulations and evoked potentials.
Nunez PL; Pilgreen KL; Westdorp AF; Law SK; Nelson AV
Brain Topogr; 1991; 4(2):151-68. PubMed ID: 1793689
[TBL] [Abstract][Full Text] [Related]
14. Effect of skull resistivity on the spatial resolutions of EEG and MEG.
Malmivuo JA; Suihko VE
IEEE Trans Biomed Eng; 2004 Jul; 51(7):1276-80. PubMed ID: 15248545
[TBL] [Abstract][Full Text] [Related]
15. On the realization of an analytic high-resolution EEG.
Edlinger G; Wach P; Pfurtscheller G
IEEE Trans Biomed Eng; 1998 Jun; 45(6):736-45. PubMed ID: 9609938
[TBL] [Abstract][Full Text] [Related]
16. Effects of electrode density and electrolyte spreading in dense array electroencephalographic recording.
Greischar LL; Burghy CA; van Reekum CM; Jackson DC; Pizzagalli DA; Mueller C; Davidson RJ
Clin Neurophysiol; 2004 Mar; 115(3):710-20. PubMed ID: 15036067
[TBL] [Abstract][Full Text] [Related]
17. A spline Laplacian ECG estimator in a realistic geometry volume conductor.
He B; Li G; Lian J
IEEE Trans Biomed Eng; 2002 Feb; 49(2):110-7. PubMed ID: 12066878
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of the distortion of EEG signals caused by a hole in the skull mimicking the fontanel in the skull of human neonates.
Flemming L; Wang Y; Caprihan A; Eiselt M; Haueisen J; Okada Y
Clin Neurophysiol; 2005 May; 116(5):1141-52. PubMed ID: 15826855
[TBL] [Abstract][Full Text] [Related]
19. Comparison of the effect of volume conduction on EEG coherence with the effect of field spread on MEG coherence.
Winter WR; Nunez PL; Ding J; Srinivasan R
Stat Med; 2007 Sep; 26(21):3946-57. PubMed ID: 17607723
[TBL] [Abstract][Full Text] [Related]
20. A spline framework for estimating the EEG surface laplacian using the Euclidean metric.
Carvalhaes CG; Suppes P
Neural Comput; 2011 Nov; 23(11):2974-3000. PubMed ID: 21851276
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]