These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 8320980)

  • 1. Predicting the leakage performance of bodyworn disposable incontinence pads using laboratory tests.
    Cottenden AM; Ledger DJ
    J Biomed Eng; 1993 May; 15(3):212-20. PubMed ID: 8320980
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predicting the leakage performance of small bodyworn disposable incontinence pads using laboratory tests.
    Cottenden AM; Dean GE; Brooks RJ
    Med Eng Phys; 1997 Sep; 19(6):556-71. PubMed ID: 9394904
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A critical investigation of ISO 11948-2 and ISO 11948-1 for predicting the leakage performance of small disposable incontinence pads for lightly incontinent women.
    Cottenden AM; Rothwell JG; Leander H; Landeryou MA; Fader MJ; Pettersson L; Brooks RJ
    Med Eng Phys; 2006 Jan; 28(1):42-8. PubMed ID: 16426978
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Incontinence pads: predicting their leakage performance using laboratory tests.
    Cottenden A; Ledger D
    Neurourol Urodyn; 1993; 12(3):289-91. PubMed ID: 8330054
    [TBL] [Abstract][Full Text] [Related]  

  • 5. How well does ISO 11948-1 (the Rothwell method) for measuring the absorption capacity of incontinence pads in the laboratory correlate with clinical pad performance.
    Cottenden AM; Fader MJ; Pettersson L; Brooks RJ
    Med Eng Phys; 2003 Sep; 25(7):603-13. PubMed ID: 12835073
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An investigation of the repeatability and reproducibility of ISO 11948-1 (the Rothwell method) for measuring the absorption capacity of incontinence pads.
    Cottenden AM; Rothwell JG; Leander H; Grau C; Brooks RJ
    Med Eng Phys; 2002 Mar; 24(2):159-63. PubMed ID: 11886836
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Absorbent products for urinary/faecal incontinence: a comparative evaluation of key product designs.
    Fader M; Cottenden A; Getliffe K; Gage H; Clarke-O'Neill S; Jamieson K; Green N; Williams P; Brooks R; Malone-Lee J
    Health Technol Assess; 2008 Jul; 12(29):iii-iv, ix-185. PubMed ID: 18547500
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An investigation of laboratory test methods for predicting the in-use leakage performance of urine-absorbing aids in nursing homes.
    Cottenden A; Macaulay M
    Proc Inst Mech Eng H; 2019 Jan; 233(1):23-34. PubMed ID: 30156126
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Disposable bedpads for incontinence: predicting their clinical leakage properties using laboratory tests.
    Cottenden AM; Dean GE; Brooks RJ; Haines-Nutt RF; Rothwell JG; Penfold PH
    Med Eng Phys; 1998 Jul; 20(5):347-59. PubMed ID: 9773688
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improving the performance of small incontinence pads: a study of "wet comfort".
    Thornburn P; Fader M; Dean G; Brooks R; Cottenden A
    J Wound Ostomy Continence Nurs; 1997 Jul; 24(4):219-25. PubMed ID: 9274279
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reducing the leakage of body-worn incontinence pads.
    Clancy B; Malone-Lee J
    J Adv Nurs; 1991 Feb; 16(2):187-93. PubMed ID: 2013661
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the home pad test in the investigation of female urinary incontinence.
    Versi E; Orrego G; Hardy E; Seddon G; Smith P; Anand D
    Br J Obstet Gynaecol; 1996 Feb; 103(2):162-7. PubMed ID: 8616134
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An Exploratory Study of Skin Problems Experienced by UK Nursing Home Residents Using Different Pad Designs.
    Clarke-OʼNeill S; Farbrot A; Lagerstedt ML; Cottenden A; Fader M
    J Wound Ostomy Continence Nurs; 2015; 42(6):621-31; quiz E1-2. PubMed ID: 26333205
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pad test by mail for home evaluation of urinary incontinence.
    Flisser AJ; Figueroa J; Bleustein CB; Panagopoulos G; Blaivas JG
    Neurourol Urodyn; 2004; 23(2):127-9. PubMed ID: 14983423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A multicenter comparative evaluation: disposable pads for women with light incontinence.
    Clarke-O'Neill S; Pettersson L; Fader M; Cottenden A; Brooks R
    J Wound Ostomy Continence Nurs; 2004; 31(1):32-42. PubMed ID: 15128093
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Patient pad count is a poor measure of urinary incontinence compared with 48-h pad test: results of a large-scale multicentre study.
    Sacco E; Bientinesi R; Gandi C; Di Gianfrancesco L; Pierconti F; Racioppi M; Bassi P
    BJU Int; 2019 May; 123(5A):E69-E78. PubMed ID: 30253042
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pad count is a poor measure of the severity of urinary incontinence.
    Tsui JF; Shah MB; Weinberger JM; Ghanaat M; Weiss JP; Purohit RS; Blaivas JG
    J Urol; 2013 Nov; 190(5):1787-90. PubMed ID: 23727311
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validity and reliability of a pad test model using a simulated urine leak and healthy continent females.
    Molloy SS; Nichols TR; Sexton WL; Murahata RI
    Urol Nurs; 2007 Aug; 27(4):300-4. PubMed ID: 17877099
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Quantification of urine leaks: standardized one-hour pad test].
    Batista Miranda JE; Da Silva Virgilio F; Granda Contijoch M; Puigpelat Font T; Errando Smet C; Araño Bertrán P
    Actas Urol Esp; 1997 Feb; 21(2):111-6. PubMed ID: 9214206
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does patient activity level affect 24-hr pad test results in stress-incontinent women?
    Painter V; Karantanis E; Moore KH
    Neurourol Urodyn; 2012 Jan; 31(1):143-7. PubMed ID: 21780173
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.