These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Quantitation of vascular outflow by measurement of impedance. Schwartz LB; Purut CM; O'Donohoe MK; Smith PK; Hagen PO; McCann RL J Vasc Surg; 1991 Sep; 14(3):353-63. PubMed ID: 1880843 [TBL] [Abstract][Full Text] [Related]
5. Prosthetic arteriovenous fistulas and venous anastomotic stenosis: influence of a high flow velocity on the development of intimal hyperplasia. Hofstra L; Bergmans DC; Leunissen KM; Hoeks AP; Kitslaar PJ; Tordoir JH Blood Purif; 1996; 14(5):345-9. PubMed ID: 8894129 [TBL] [Abstract][Full Text] [Related]
6. Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosis. Ene-Iordache B; Remuzzi A Nephrol Dial Transplant; 2012 Jan; 27(1):358-68. PubMed ID: 21771751 [TBL] [Abstract][Full Text] [Related]
7. Axial flow fields in cuffed end-to-side anastomoses: effect of angle and disease progression. Wijesinghe LD; Mahmood T; Scott DJ Eur J Vasc Endovasc Surg; 1999 Sep; 18(3):240-4. PubMed ID: 10479631 [TBL] [Abstract][Full Text] [Related]
8. Flow pattern and shear stress distribution of distal end-to-side anastomoses. A comparison of the instantaneous velocity fields obtained by particle image velocimetry. Heise M; Schmidt S; Krüger U; Rückert R; Rösler S; Neuhaus P; Settmacher U J Biomech; 2004 Jul; 37(7):1043-51. PubMed ID: 15165874 [TBL] [Abstract][Full Text] [Related]
9. Simulated hemodynamic comparison of arteriovenous fistulas. van Gemert MJ; Bruyninckx CM J Vasc Surg; 1987 Jul; 6(1):39-44. PubMed ID: 3599279 [TBL] [Abstract][Full Text] [Related]
10. Microvascular stress analysis: Part II. Effects of vascular wall compliance on blood flow at the graft/recipient vessel junction. Al-Sukhun J; Penttilä H; Ashammakhi N J Craniofac Surg; 2011 May; 22(3):883-7. PubMed ID: 21558923 [TBL] [Abstract][Full Text] [Related]
11. Numerical investigations of the unsteady blood flow in the end-to-side arteriovenous fistula for hemodialysis. Jodko D; Obidowski D; Reorowicz P; Jóźwik K Acta Bioeng Biomech; 2016; 18(4):3-13. PubMed ID: 28133372 [TBL] [Abstract][Full Text] [Related]
12. In vitro testing of a newly developed arteriovenous double-outflow graft. Heise M; Kirschner P; Rabsch A; Zanow J; Settmacher U; Heidenhain C J Vasc Surg; 2010 Aug; 52(2):421-8. PubMed ID: 20591600 [TBL] [Abstract][Full Text] [Related]
13. Comparison of the hemodynamics in 6mm and 4-7 mm hemodialysis grafts by means of CFD. Van Tricht I; De Wachter D; Tordoir J; Verdonck P J Biomech; 2006; 39(2):226-36. PubMed ID: 16321624 [TBL] [Abstract][Full Text] [Related]
14. Tailoring of arteriovenous graft-to-vein anastomosis angle to attenuate pathological flow fields. Williams D; Leuthardt EC; Genin GM; Zayed M Sci Rep; 2021 Jun; 11(1):12153. PubMed ID: 34108499 [TBL] [Abstract][Full Text] [Related]
15. Investigations into the relationship between hemodynamics and vascular alterations in an established arteriovenous fistula. Kharboutly Z; Fenech M; Treutenaere JM; Claude I; Legallais C Med Eng Phys; 2007 Nov; 29(9):999-1007. PubMed ID: 17137826 [TBL] [Abstract][Full Text] [Related]
16. Experimental and Numerical Analysis of the Bulk Flow Parameters Within an Arteriovenous Fistula. Browne LD; Walsh MT; Griffin P Cardiovasc Eng Technol; 2015 Dec; 6(4):450-62. PubMed ID: 26577478 [TBL] [Abstract][Full Text] [Related]
17. The relation between vascular access flow and different types of vascular access with systemic hemodynamics in hemodialysis patients. Wijnen E; Keuter XH; Planken NR; van der Sande FM; Tordoir JH; Leunissen KM; Kooman JP Artif Organs; 2005 Dec; 29(12):960-4. PubMed ID: 16305651 [TBL] [Abstract][Full Text] [Related]
18. [Evaluation of blood flow using a reservoir flowmeter of several types of arteriovenous fistulas in chronic hemodialysis treatment]. Simoni G; Binda PL; Brignole E; Friedman D; Pitton L; Traverso E; Vita M Boll Soc Ital Biol Sper; 1981 Jun; 57(12):1287-92. PubMed ID: 6457609 [TBL] [Abstract][Full Text] [Related]
19. [Arteriovenous fistulas for hemodialysis--patency rates and complications--a retrospective study]. Tautenhahn J; Heinrich P; Meyer F Zentralbl Chir; 1994; 119(7):506-10. PubMed ID: 7941799 [TBL] [Abstract][Full Text] [Related]