These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 8322789)

  • 1. Factors affecting delivery of high-efficiency dialysis using temporary vascular access.
    Kelber J; Delmez JA; Windus DW
    Am J Kidney Dis; 1993 Jul; 22(1):24-9. PubMed ID: 8322789
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blood recirculation in temporary central catheters for acute hemodialysis.
    Leblanc M; Fedak S; Mokris G; Paganini EP
    Clin Nephrol; 1996 May; 45(5):315-9. PubMed ID: 8738663
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Recirculation of urea and dialysis efficiency using dual-lumen dialysis catheters in various locations: may the venous lumen of the catheter be used as the arterial lumen and vice versa?].
    Sefer S; Kes P; Degoricija V; Heinrich B; Vrsalović M
    Lijec Vjesn; 2003; 125(1-2):1-5. PubMed ID: 12812016
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Access recirculation in temporary hemodialysis catheters as measured by the saline dilution technique.
    Little MA; Conlon PJ; Walshe JJ
    Am J Kidney Dis; 2000 Dec; 36(6):1135-9. PubMed ID: 11096037
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of twin central venous catheters: influence of the inversion of inlet and outlet on recirculation.
    Level C; Lasseur C; Chauveau P; Bonarek H; Perrault L; Combe C
    Blood Purif; 2002; 20(2):182-8. PubMed ID: 11818683
    [TBL] [Abstract][Full Text] [Related]  

  • 6. All currently used measurements of recirculation in blood access by chemical methods are flawed due to intradialytic disequilibrium or recirculation at low flow.
    Twardowski ZJ; Van Stone JC; Haynie JD
    Am J Kidney Dis; 1998 Dec; 32(6):1046-58. PubMed ID: 9856523
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Vascular access recirculation in hemodialysis patients with two noncuffed, single-lumen, jugular catheters in the same jugular vein.
    Kovac J; Buturović-Ponikvar J; Ponikvar R
    Ther Apher Dial; 2009 Aug; 13(4):350-3. PubMed ID: 19695073
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Temporary hemodialysis catheters as a long-term vascular access in chronic hemodialysis patients.
    Ponikvar R; Buturović-Ponikvar J
    Ther Apher Dial; 2005 Jun; 9(3):250-3. PubMed ID: 15967000
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Access for starting kidney replacement therapy: vascular and peritoneal temporal access in pre-dialysis].
    Rodríguez CR; Bardón Otero E; Vila Paz ML
    Nefrologia; 2008; 28 Suppl 3():105-12. PubMed ID: 19018747
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy of dual lumen jugular venous catheter hemodialysis when venous lumen is used as arterial lumen.
    Sombolos K; Natse T; Zoumbaridis N; Mavromatidis K; Karagianni A; Fitili C
    Nephron; 1993; 65(1):147-9. PubMed ID: 8413774
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Upper body central venous catheters in pediatric cardiac surgery.
    Miller JW; Vu DN; Chai PJ; Kreutzer JH; John JB; Vener DF; Jacobs JP
    Paediatr Anaesth; 2013 Nov; 23(11):980-8. PubMed ID: 24088201
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Temporary vascular access for extra-renal detoxification: utilization of tunneled silicone double-lumen catheters by the percutaneous route].
    Jean G; Chazot C; Vanel T
    Nephrologie; 1994; 15(2):81-2. PubMed ID: 8047221
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemodialysis catheters with citrate locking in critically ill patients with acute kidney injury treated with intermittent online hemofiltration or hemodialysis.
    Skofic N; Buturović-Ponikvar J; Kovac J; Premru V; Knap B; Marn Pernat A; Kersnic B; Gubensek J; Ponikvar R
    Ther Apher Dial; 2009 Aug; 13(4):327-33. PubMed ID: 19695069
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Tunneled dialysis catheters placement program in Clinical Hospital Merkur].
    Mihovilović K; Maksimović B; Knotek M
    Acta Med Croatica; 2011 Oct; 65 Suppl 3():54-7. PubMed ID: 23120817
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Urea concentration gradients during conventional hemodialysis.
    Sombolos K; Natse T; Zoumbaridis N; Mavromatidis K; Karagianni A; Scandalos J; Fitili C
    Am J Kidney Dis; 1996 May; 27(5):673-9. PubMed ID: 8629627
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of blood recirculation in catheters for haemodialysis and its relation to blood circuit pressures.
    Crespo Montero R; Casas Cuesta R; Muñoz Navarro MC; Contreras MD; Alguacil Garrido I; López Bermúdez E
    EDTNA ERCA J; 2002; 28(4):167-9. PubMed ID: 12638929
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The impact of increased blood flow rates on recirculation in central venous hemodialysis catheters.
    Szabo J; Locking-Cusolito H
    Nephrol Nurs J; 2001 Dec; 28(6):639-41. PubMed ID: 12143473
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: a systematic review of the literature and meta-analysis.
    Marik PE; Flemmer M; Harrison W
    Crit Care Med; 2012 Aug; 40(8):2479-85. PubMed ID: 22809915
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of urea recirculation and dialysis efficiency of central venous jugular catheters when the venous lumen is used as an arterial lumen].
    Dionisio P; Valenti M; Bergia R; Caramello E; Berto MI; Cravero R; Agostini B; Vallero A; Bajardi P
    Minerva Urol Nefrol; 1999 Jun; 51(2):61-5. PubMed ID: 10429412
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous internal jugular vein catheterization with double lumen for temporary hemodialysis: experience of 100 cases.
    Fang JT; Huang CC
    Changgeng Yi Xue Za Zhi; 1992 Sep; 15(3):114-20. PubMed ID: 1468033
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.