These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 8329525)
1. Radiological and histological study of aseptic loosening using a cemented tibial hemiarthroplasty in the rabbit knee. Goodman SB; Magee FP; Fornasier VL Biomaterials; 1993 Jun; 14(7):522-8. PubMed ID: 8329525 [TBL] [Abstract][Full Text] [Related]
2. Prostaglandin E2 production by the membrane surrounding loose and fixated cemented tibial hemiarthroplasties in the rabbit knee. Goodman SB; Chin RC; Magee FP Clin Orthop Relat Res; 1992 Nov; (284):283-7. PubMed ID: 1395306 [TBL] [Abstract][Full Text] [Related]
3. Lysosomal enzyme production at the interface surrounding loose and well-fixed cemented tibial hemiarthroplasties in the rabbit knee. Goodman SB; Kang T; Smith RL J Invest Surg; 1993; 6(5):413-8. PubMed ID: 8292569 [TBL] [Abstract][Full Text] [Related]
4. A Novel Percentage-Based System for Determining Aseptic Loosening of Total Knee Arthroplasty Tibial Components. Chalmers BP; Sculco PK; Fehring KA; Trousdale RT; Taunton MJ J Arthroplasty; 2017 Jul; 32(7):2274-2278. PubMed ID: 28285901 [TBL] [Abstract][Full Text] [Related]
5. Survival, complications and functional outcomes of cemented megaprostheses for high-grade osteosarcoma around the knee. Zhang C; Hu J; Zhu K; Cai T; Ma X Int Orthop; 2018 Apr; 42(4):927-938. PubMed ID: 29427125 [TBL] [Abstract][Full Text] [Related]
6. Underhang of the tibial component increases tibial bone resorption after total knee arthroplasty. Gu S; Kuriyama S; Nakamura S; Nishitani K; Ito H; Matsuda S Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1270-1279. PubMed ID: 30470851 [TBL] [Abstract][Full Text] [Related]
7. Impact of a double-layer cementing technique on the homogeneity of cementation and the generation of loose bone cement fragments in tibial unicompartmental knee arthroplasty. Scheele CB; Pietschmann MF; Schröder C; Suren C; Grupp TM; Müller PE BMC Musculoskelet Disord; 2019 Nov; 20(1):539. PubMed ID: 31722711 [TBL] [Abstract][Full Text] [Related]
8. Is cement mantle thickness a primary cause of aseptic tibial loosening following primary total knee arthroplasty? Cox ZC; Engstrom SM; Shinar AA; Polkowski GG; Mason JB; Martin JR Knee; 2023 Jan; 40():305-312. PubMed ID: 36592499 [TBL] [Abstract][Full Text] [Related]
9. Zirconium as a Promising Synovial Biomarker for Loose Cemented Knee Prosthesis. Anderson PM; Heinz T; Weißenberger M; Winter P; Rudert M; Jakuscheit A J Arthroplasty; 2024 Jul; 39(7):1714-1718. PubMed ID: 38244639 [TBL] [Abstract][Full Text] [Related]
10. Where Is the "Weak Link" of Fixation in Contemporary Cemented Total Knee Replacements? Martin JR; Otero JE; Mason JB; Fehring TK J Arthroplasty; 2021 Jul; 36(7):2497-2501. PubMed ID: 33676813 [TBL] [Abstract][Full Text] [Related]
11. Changes in tibial bone density measured from standard radiographs in cemented and uncemented total knee replacements after ten years' follow-up. Small SR; Ritter MA; Merchun JG; Davis KE; Rogge RD Bone Joint J; 2013 Jul; 95-B(7):911-6. PubMed ID: 23814242 [TBL] [Abstract][Full Text] [Related]
12. Trabecular metal tibial knee component still stable at 10 years. Henricson A; Nilsson KG Acta Orthop; 2016 Oct; 87(5):504-10. PubMed ID: 27357222 [TBL] [Abstract][Full Text] [Related]
13. [Quality of tibial cementing in total knee arthroplasty: one or two phase cementing of the tibial and femoral implants]. Pujol N; Verdot FX; Chambat P Rev Chir Orthop Reparatrice Appar Mot; 2008 May; 94(3):241-6. PubMed ID: 18456058 [TBL] [Abstract][Full Text] [Related]
14. Cement penetration and stiffness of the cement-bone composite in the proximal tibia in a porcine model. Bauze AJ; Costi JJ; Stavrou P; Rankin WA; Hearn TC; Krishnan J; Slavotinek JP J Orthop Surg (Hong Kong); 2004 Dec; 12(2):194-8. PubMed ID: 15621906 [TBL] [Abstract][Full Text] [Related]
15. [Surface pretreatment for prolonged survival of cemented tibial prosthesis components: full- vs. surface-cementation technique]. Mumme T; Marx R; Qunaibi M; Niethard FU; Wirtz DC Biomed Tech (Berl); 2006 Jul; 51(2):95-102. PubMed ID: 16915772 [TBL] [Abstract][Full Text] [Related]
16. Low Rates of Aseptic Tibial Loosening in Obese Patients With Use of High-Viscosity Cement and Standard Tibial Tray: 2-Year Minimum Follow-Up. Crawford DA; Berend KR; Nam D; Barrack RL; Adams JB; Lombardi AV J Arthroplasty; 2017 Sep; 32(9S):S183-S186. PubMed ID: 28511945 [TBL] [Abstract][Full Text] [Related]
17. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years. Lachiewicz PF; Soileau ES J Bone Joint Surg Am; 2004 Mar; 86(3):525-30. PubMed ID: 14996878 [TBL] [Abstract][Full Text] [Related]
18. Progressive loss of implant fixation in a preclinical rat model of cemented knee arthroplasty. Mann KA; Miller MA; Rossow JK; Tatusko ME; Horton JA; Damron TA; Oest ME J Orthop Res; 2021 Nov; 39(11):2353-2362. PubMed ID: 33382095 [TBL] [Abstract][Full Text] [Related]
20. Development and characteristics of a synovial-like interface membrane around cemented tibial hemiarthroplasties in a novel rat model of aseptic prosthesis loosening. Pap G; Machner A; Rinnert T; Hörler D; Gay RE; Schwarzberg H; Neumann W; Michel BA; Gay S; Pap T Arthritis Rheum; 2001 Apr; 44(4):956-63. PubMed ID: 11315935 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]