BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 8330410)

  • 1. Analytical goals developed from the inherent error of medical tests.
    Ross JW; Fraser MD
    Clin Chem; 1993 Jul; 39(7):1481-93; discussion 1493-4. PubMed ID: 8330410
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analytical goal-setting for monitoring patients when two analytical methods are used.
    Petersen PH; Fraser CG; Westgard JO; Larsen ML
    Clin Chem; 1992 Nov; 38(11):2256-60. PubMed ID: 1424120
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Setting analytical goals for random analytical error in specific clinical monitoring situations.
    Fraser CG; Hyltoft Peterson P; Larsen ML
    Clin Chem; 1990 Sep; 36(9):1625-8. PubMed ID: 2208703
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity.
    Klee GG
    Clin Chem; 1993 Jul; 39(7):1514-8. PubMed ID: 8330413
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Analytical uncertainty--how wrong can a laboratory result be?].
    Bolann BJ; Stølsnes B
    Tidsskr Nor Laegeforen; 1999 Dec; 119(30):4472-5. PubMed ID: 10827487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cholesterol operational process specifications for assuring the quality required by CLIA proficiency testing.
    Westgard JO; Wiebe DA
    Clin Chem; 1991 Nov; 37(11):1938-44. PubMed ID: 1934469
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analytical goals for interference.
    Fuentes-Arderiu X; Fraser CG
    Ann Clin Biochem; 1991 Jul; 28 ( Pt 4)():393-5. PubMed ID: 1892351
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new concept to derive permissible limits for analytical imprecision and bias considering diagnostic requirements and technical state-of-the-art.
    Haeckel R; Wosniok W
    Clin Chem Lab Med; 2011 Apr; 49(4):623-35. PubMed ID: 21345158
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analytical goals for rectilinear calibration functions.
    Fuentes-Arderiu X; Alía P; Machuca I
    Clin Chim Acta; 1994 Jan; 224(2):119-23. PubMed ID: 8004781
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Governmental perspectives on evaluating laboratory performance.
    Boone DJ
    Clin Chem; 1993 Jul; 39(7):1461-5; discussion 1466-7. PubMed ID: 8330408
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The necessity of achieving good laboratory performance.
    Fraser CG
    Diabet Med; 1990 Jul; 7(6):490-3. PubMed ID: 2142050
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analytical goals for the estimation of non-Gaussian reference intervals.
    Hyltoft Petersen P; Gowans EM; Blaabjerg O; Hørder M
    Scand J Clin Lab Invest; 1989 Dec; 49(8):727-37. PubMed ID: 2617130
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Setting performance goals and evaluating total analytical error for diagnostic assays.
    Krouwer JS
    Clin Chem; 2002 Jun; 48(6 Pt 1):919-27. PubMed ID: 12029009
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Graphical interpretation of analytical data from comparison of a field method with reference method by use of difference plots.
    Petersen PH; Stöckl D; Blaabjerg O; Pedersen B; Birkemose E; Thienpont L; Lassen JF; Kjeldsen J
    Clin Chem; 1997 Nov; 43(11):2039-46. PubMed ID: 9365386
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analytical performance goals for measuring prostate-specific antigen.
    Fritsche HA; Babaian RJ
    Clin Chem; 1993 Jul; 39(7):1525-7; discussion 1527-9. PubMed ID: 7687205
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The discordance rate, a new concept for combining diagnostic decisions with analytical performance characteristics. 2. Defining analytical goals applied to the diagnosis of type 2 diabetes by blood glucose concentrations.
    Haeckel R; Wosniok W
    Clin Chem Lab Med; 2004 Feb; 42(2):198-203. PubMed ID: 15061361
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision.
    Liu J; Tan CH; Badrick T; Loh TP
    Clin Biochem; 2018 Feb; 52():112-116. PubMed ID: 29107011
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Description of a generally applicable model for the evaluation of uncertainty of measurement in clinical chemistry.
    Kristiansen J
    Clin Chem Lab Med; 2001 Oct; 39(10):920-31. PubMed ID: 11758604
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analytical goals for haematology tests.
    Fraser CG
    Eur J Haematol Suppl; 1990; 53():2-5. PubMed ID: 2279551
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of analytical run length on quality-control (QC) performance and the QC planning process.
    Parvin CA; Gronowski AM
    Clin Chem; 1997 Nov; 43(11):2149-54. PubMed ID: 9365401
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.