BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 8338931)

  • 1. Blood recirculation in intravenous catheters for hemodialysis.
    Twardowski ZJ; Van Stone JC; Jones ME; Klusmeyer ME; Haynie JD
    J Am Soc Nephrol; 1993 Jun; 3(12):1978-81. PubMed ID: 8338931
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blood recirculation in malfunctioning catheters for haemodialysis.
    Crespo R; Rivero MF; Contreras MD; Martínez A; Labrador A; Jurado MJ; Casas R
    EDTNA ERCA J; 1999; 25(1):38-9. PubMed ID: 10418377
    [TBL] [Abstract][Full Text] [Related]  

  • 3. All currently used measurements of recirculation in blood access by chemical methods are flawed due to intradialytic disequilibrium or recirculation at low flow.
    Twardowski ZJ; Van Stone JC; Haynie JD
    Am J Kidney Dis; 1998 Dec; 32(6):1046-58. PubMed ID: 9856523
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Blood recirculation in temporary central catheters for acute hemodialysis.
    Leblanc M; Fedak S; Mokris G; Paganini EP
    Clin Nephrol; 1996 May; 45(5):315-9. PubMed ID: 8738663
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of recirculation percentage of the palindrome catheter and standard hemodialysis catheters in a swine model.
    Tal MG
    J Vasc Interv Radiol; 2005 Sep; 16(9):1237-40. PubMed ID: 16151065
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Recirculation of urea and dialysis efficiency using dual-lumen dialysis catheters in various locations: may the venous lumen of the catheter be used as the arterial lumen and vice versa?].
    Sefer S; Kes P; Degoricija V; Heinrich B; Vrsalović M
    Lijec Vjesn; 2003; 125(1-2):1-5. PubMed ID: 12812016
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Peripheral venous blood is not the appropriate specimen to determine the amount of recirculation during hemodialysis.
    Van Stone JC
    ASAIO J; 1996; 42(1):41-5. PubMed ID: 8808457
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hemodialysis catheter tip design: observations on fluid flow and recirculation.
    Vesely TM; Ravenscroft A
    J Vasc Access; 2016; 17(1):29-39. PubMed ID: 26349860
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Severe access recirculation secondary to free flow between the lumens of a dual-lumen dialysis catheter.
    Sarnak MJ; Halin N; King AJ
    Am J Kidney Dis; 1999 Jun; 33(6):1168-70. PubMed ID: 10352209
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of reversal of catheter ports on recirculation: comparison of the PermCath with Tesio Twin Catheter.
    Hassan HA; Frenchie DL; Bastani B
    ASAIO J; 2002; 48(3):316-9. PubMed ID: 12059008
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reversed connection of cuffed, tunneled, dual-lumen catheters with increased blood flow rate maintains the adequacy of delivered dialysis despite the higher access recirculation.
    Kousoula V; Georgianos PI; Mavromatidis K; Syrganis C; Thodis E; Panagoutsos S; Passadakis P
    Int Urol Nephrol; 2019 Oct; 51(10):1841-1847. PubMed ID: 31471844
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study of access recirculation in reversed temporary indwelling catheters.
    Laurin L; Twolan C
    J CANNT; 1994; 4(2):11-2. PubMed ID: 7999476
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of symmetric hemodialysis catheters using computational fluid dynamics.
    Clark TW; Isu G; Gallo D; Verdonck P; Morbiducci U
    J Vasc Interv Radiol; 2015 Feb; 26(2):252-9.e2. PubMed ID: 25645414
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vascular access recirculation in hemodialysis patients with two noncuffed, single-lumen, jugular catheters in the same jugular vein.
    Kovac J; Buturović-Ponikvar J; Ponikvar R
    Ther Apher Dial; 2009 Aug; 13(4):350-3. PubMed ID: 19695073
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computational flow dynamics and preclinical assessment of a novel hemodialysis catheter.
    Clark TW; Van Canneyt K; Verdonck P
    Semin Dial; 2012; 25(5):574-81. PubMed ID: 22353667
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Access recirculation in temporary hemodialysis catheters as measured by the saline dilution technique.
    Little MA; Conlon PJ; Walshe JJ
    Am J Kidney Dis; 2000 Dec; 36(6):1135-9. PubMed ID: 11096037
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance of twin central venous catheters: influence of the inversion of inlet and outlet on recirculation.
    Level C; Lasseur C; Chauveau P; Bonarek H; Perrault L; Combe C
    Blood Purif; 2002; 20(2):182-8. PubMed ID: 11818683
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of the tip structure of temporary indwelling catheters on blood recirculation at various blood flow rates and diameters of the mock blood vessel.
    Sato Y; Yanagisawa K; Hachitani Y; Ueki S; Kurihara Y; Kobayashi K; Kokubo K
    J Vasc Access; 2024 Mar; 25(2):481-489. PubMed ID: 36000811
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Urea concentration gradients during conventional hemodialysis.
    Sombolos K; Natse T; Zoumbaridis N; Mavromatidis K; Karagianni A; Scandalos J; Fitili C
    Am J Kidney Dis; 1996 May; 27(5):673-9. PubMed ID: 8629627
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Urea clearance in dysfunctional catheters is improved by reversing the line position despite increased access recirculation.
    Carson RC; Kiaii M; MacRae JM
    Am J Kidney Dis; 2005 May; 45(5):883-90. PubMed ID: 15861354
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.