These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

243 related articles for article (PubMed ID: 8339477)

  • 21. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.
    Digas G
    Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Aseptic loosening in total hip implants: the role of polyethylene wear debris.
    Boynton E; Waddell JP; Morton J; Gardiner GW
    Can J Surg; 1991 Dec; 34(6):599-605. PubMed ID: 1747840
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Osteolysis in cemented titanium alloy hip prosthesis.
    Schöll E; Eggli S; Ganz R
    J Arthroplasty; 2000 Aug; 15(5):570-5. PubMed ID: 10959994
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads.
    Lombardi AV; Mallory TH; Vaughn BK; Drouillard P
    J Bone Joint Surg Am; 1989 Oct; 71(9):1337-42. PubMed ID: 2793886
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effects of particles on fibroblast proliferation and bone resorption in vitro.
    Shanbhag AS; Jacobs JJ; Black J; Galante JO; Glant TT
    Clin Orthop Relat Res; 1997 Sep; (342):205-17. PubMed ID: 9308543
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Mechanism of failure in hips with an uncemented, all polyethylene socket.
    Llinás A; Sarmiento A; Ebramzadeh E; Park SH; Campbell P; McKellop HA
    Clin Orthop Relat Res; 1999 May; (362):145-55. PubMed ID: 10335293
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Wear characteristics of different metal-polyethylene beating surfaces. An experimental study of a new model of knee prosthesis].
    Farizon F; Aurelle JL; Rieu J; Bousquet G
    Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(6):522-8. PubMed ID: 9122523
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Wear induced by motion between bone and titanium or cobalt-chrome alloys.
    Bischoff UW; Freeman MA; Smith D; Tuke MA; Gregson PJ
    J Bone Joint Surg Br; 1994 Sep; 76(5):713-6. PubMed ID: 8083256
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Good long term results with a cemented straight femoral shaft prosthesis made of titanium].
    Eingartner C; Ihm A; Maurer F; Volkmann R; Weise K; Weller S
    Unfallchirurg; 2002 Sep; 105(9):804-10. PubMed ID: 12232740
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Should monobloc cemented stems be systematically revised during revision total hip arthroplasty? A prospective evaluation].
    Grosjean G; Courpied JP; Moindreau M; Hunou N; Mathieu M; Hamadouche M
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Nov; 94(7):670-7. PubMed ID: 18984124
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Wear and corrosion of modular interfaces in total hip replacements.
    Cook SD; Barrack RL; Baffes GC; Clemow AJ; Serekian P; Dong N; Kester MA
    Clin Orthop Relat Res; 1994 Jan; (298):80-8. PubMed ID: 8119000
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Mode of loosening of matt-finished femoral stems in primary total hip replacement.
    Behairy YM; Harris WH
    Saudi Med J; 2002 Oct; 23(10):1187-94. PubMed ID: 12436120
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty.
    Bragdon CR; O'Connor DO; Lowenstein JD; Jasty M; Biggs SA; Harris WH
    J Arthroplasty; 2001 Aug; 16(5):658-65. PubMed ID: 11503127
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Extraction and characterization of metallic wear debris from total joint arthroplasty.
    Schmiedberg SK; Jones LC; Chang DH; Hungerford DS; Frondoza CG
    Biomed Sci Instrum; 2007; 43():104-9. PubMed ID: 17487065
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Extensive porosity at the cement-femoral prosthesis interface: a preliminary study.
    James SP; Schmalzried TP; McGarry FJ; Harris WH
    J Biomed Mater Res; 1993 Jan; 27(1):71-8. PubMed ID: 8421001
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis.
    La Budde JK; Orosz JF; Bonfiglio TA; Pellegrini VD
    J Arthroplasty; 1994 Jun; 9(3):291-304. PubMed ID: 8077978
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Preparation and characterization of wear debris of orthopedic materials for biocompatibility studies.
    Wagner CN; Shabaik AH
    J Biomed Mater Res; 1976 Sep; 10(5):653-70. PubMed ID: 977601
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Metallic wear debris in dual modular hip arthroplasty.
    Baleani M; Viceconti M; Walchholz K; Toni A
    Chir Organi Mov; 1997; 82(3):231-8. PubMed ID: 9494240
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Characterization of wear debris in total elbow arthroplasty.
    Day JS; Baxter RM; Ramsey ML; Morrey BF; Connor PM; Kurtz SM; Steinbeck MJ
    J Shoulder Elbow Surg; 2013 Jul; 22(7):924-31. PubMed ID: 23582703
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A prospective study of a titanium femoral component for cemented total hip arthroplasty.
    Tompkins GS; Lachiewicz PF; DeMasi R
    J Arthroplasty; 1994 Dec; 9(6):623-30. PubMed ID: 7699375
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.