177 related articles for article (PubMed ID: 8339577)
1. Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients.
Sageman WS; Amundson DE
Crit Care Med; 1993 Aug; 21(8):1139-42. PubMed ID: 8339577
[TBL] [Abstract][Full Text] [Related]
2. Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM3 after coronary bypass surgery.
Thomas AN; Ryan J; Doran BR; Pollard BJ
Intensive Care Med; 1991; 17(7):383-6. PubMed ID: 1774390
[TBL] [Abstract][Full Text] [Related]
3. Cardiac output can be reliably measured noninvasively after coronary artery bypass grafting operation.
Kööbi T; Kaukinen S; Turjanmaa VM
Crit Care Med; 1999 Oct; 27(10):2206-11. PubMed ID: 10548208
[TBL] [Abstract][Full Text] [Related]
4. A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography.
Marik PE; Pendelton JE; Smith R
Crit Care Med; 1997 Sep; 25(9):1545-50. PubMed ID: 9295830
[TBL] [Abstract][Full Text] [Related]
5. Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation.
Preiser JC; Daper A; Parquier JN; Contempré B; Vincent JL
Intensive Care Med; 1989; 15(4):221-3. PubMed ID: 2745864
[TBL] [Abstract][Full Text] [Related]
6. Noninvasive whole-body electrical bioimpedance cardiac output and invasive thermodilution cardiac output in high-risk surgical patients.
Imhoff M; Lehner JH; Löhlein D
Crit Care Med; 2000 Aug; 28(8):2812-8. PubMed ID: 10966255
[TBL] [Abstract][Full Text] [Related]
7. Whole-body impedance cardiography in the measurement of cardiac output.
Kööbi T; Kaukinen S; Turjanmaa VM; Uusitalo AJ
Crit Care Med; 1997 May; 25(5):779-85. PubMed ID: 9187596
[TBL] [Abstract][Full Text] [Related]
8. Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography.
Kaukinen S; Kööbi T; Bi Y; Turjanmaa VM
J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):199-203. PubMed ID: 12698402
[TBL] [Abstract][Full Text] [Related]
9. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution.
Suttner S; Schöllhorn T; Boldt J; Mayer J; Röhm KD; Lang K; Piper SN
Intensive Care Med; 2006 Dec; 32(12):2053-8. PubMed ID: 17039348
[TBL] [Abstract][Full Text] [Related]
10. Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery.
Sageman WS; Riffenburgh RH; Spiess BD
J Cardiothorac Vasc Anesth; 2002 Feb; 16(1):8-14. PubMed ID: 11854871
[TBL] [Abstract][Full Text] [Related]
11. Esophageal electrodes allow precise assessment of cardiac output by bioimpedance.
Balestra B; Malacrida R; Leonardi L; Suter P; Marone C
Crit Care Med; 1992 Jan; 20(1):62-7. PubMed ID: 1729048
[TBL] [Abstract][Full Text] [Related]
12. Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation.
Shoemaker WC; Wo CC; Bishop MH; Appel PL; Van de Water JM; Harrington GR; Wang X; Patil RS
Crit Care Med; 1994 Dec; 22(12):1907-12. PubMed ID: 7988125
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study.
Haller M; Zöllner C; Briegel J; Forst H
Crit Care Med; 1995 May; 23(5):860-6. PubMed ID: 7736744
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of impedance cardiography: comparison of NCCOM3-R7 with Fick and thermodilution methods.
Yakimets J; Jensen L
Heart Lung; 1995; 24(3):194-206. PubMed ID: 7622393
[TBL] [Abstract][Full Text] [Related]
15. Non-invasive measurement of cardiac output during coronary artery bypass grafting.
Cohen AJ; Arnaudov D; Zabeeda D; Schultheis L; Lashinger J; Schachner A
Eur J Cardiothorac Surg; 1998 Jul; 14(1):64-9. PubMed ID: 9726617
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization.
Barin E; Haryadi DG; Schookin SI; Westenskow DR; Zubenko VG; Beliaev KR; Morozov AA
Crit Care Med; 2000 Mar; 28(3):698-702. PubMed ID: 10752817
[TBL] [Abstract][Full Text] [Related]
17. Determination of cardiac output during positive end-expiratory pressure--noninvasive electrical bioimpedance compared with standard thermodilution.
Castor G; Molter G; Helms J; Niedermark I; Altmayer P
Crit Care Med; 1990 May; 18(5):544-6. PubMed ID: 2183967
[TBL] [Abstract][Full Text] [Related]
18. Cardiac output determination from endotracheally measured impedance cardiography: clinical evaluation of endotracheal cardiac output monitor.
Maus TM; Reber B; Banks DA; Berry A; Guerrero E; Manecke GR
J Cardiothorac Vasc Anesth; 2011 Oct; 25(5):770-5. PubMed ID: 21354828
[TBL] [Abstract][Full Text] [Related]
19. Lack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients.
Barry BN; Mallick A; Bodenham AR; Vucevic M
Crit Care; 1997; 1(2):71-74. PubMed ID: 11056698
[TBL] [Abstract][Full Text] [Related]
20. Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution.
Doering L; Lum E; Dracup K; Friedman A
Crit Care Med; 1995 Oct; 23(10):1667-73. PubMed ID: 7587231
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]