109 related articles for article (PubMed ID: 8350834)
1. Dosimetry of 125I sources in a low-density material using scaling.
Rashid H; Bjarngard BE; Chin LM; Rice RK
Med Phys; 1993; 20(3):765-8. PubMed ID: 8350834
[TBL] [Abstract][Full Text] [Related]
2. A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources.
Meigooni AS; Meli JA; Nath R
Med Phys; 1988; 15(5):695-701. PubMed ID: 3185404
[TBL] [Abstract][Full Text] [Related]
3. Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code.
Bohm TD; DeLuca PM; DeWerd LA
Med Phys; 2003 Apr; 30(4):701-11. PubMed ID: 12722822
[TBL] [Abstract][Full Text] [Related]
4. Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study.
Luxton G
Med Phys; 1994 May; 21(5):631-41. PubMed ID: 7935197
[TBL] [Abstract][Full Text] [Related]
5. [Rigid phantom dosimetry of brachytherapy sources, with special reference to 125-I].
Arcovito G; Piermattei A; Bacci C; Pittella G; Castagnola M
Radiol Med; 1985 Jun; 71(6):426-32. PubMed ID: 4070702
[TBL] [Abstract][Full Text] [Related]
6. The use of new GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water phantom.
Chiu-Tsao ST; Medich D; Munro J
Med Phys; 2008 Aug; 35(8):3787-99. PubMed ID: 18777938
[TBL] [Abstract][Full Text] [Related]
7. Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.
Melhus CS; Rivard MJ
Med Phys; 2006 Jun; 33(6):1729-37. PubMed ID: 16872080
[TBL] [Abstract][Full Text] [Related]
8. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition.
Landry G; Reniers B; Murrer L; Lutgens L; Gurp EB; Pignol JP; Keller B; Beaulieu L; Verhaegen F
Med Phys; 2010 Oct; 37(10):5188-98. PubMed ID: 21089752
[TBL] [Abstract][Full Text] [Related]
9. Polymer gel dosimetry close to an 125I interstitial brachytherapy seed.
Pantelis E; Lymperopoulou G; Papagiannis P; Sakelliou L; Stiliaris E; Sandilos P; Seimenis I; Kozicki M; Rosiak JM
Phys Med Biol; 2005 Sep; 50(18):4371-84. PubMed ID: 16148399
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.
Lesperance M; Martinov M; Thomson RM
Med Phys; 2014 Mar; 41(3):031706. PubMed ID: 24593710
[TBL] [Abstract][Full Text] [Related]
11. Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study [Med. Phys. 21, 631-641 (1994)].
Luxton G
Med Phys; 1994 Dec; 21(12):1989-90. PubMed ID: 7700208
[No Abstract] [Full Text] [Related]
12. Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy.
Thomson RM; Taylor RE; Rogers DW
Med Phys; 2008 Dec; 35(12):5530-43. PubMed ID: 19175111
[TBL] [Abstract][Full Text] [Related]
13. Diode dosimetry of models 6711 and 6712 125I seeds in a water phantom.
Ahmad M; Fontenla DP; Chiu-Tsao ST; Chui CS; Reiff JE; Anderson LL; Huang DY; Schell MC
Med Phys; 1992; 19(2):391-9. PubMed ID: 1584138
[TBL] [Abstract][Full Text] [Related]
14. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.
Rivard MJ; Coursey BM; DeWerd LA; Hanson WF; Huq MS; Ibbott GS; Mitch MG; Nath R; Williamson JF
Med Phys; 2004 Mar; 31(3):633-74. PubMed ID: 15070264
[TBL] [Abstract][Full Text] [Related]
15. Dose distribution of 125I sources in different tissues.
Huang DY; Schell MC; Weaver KA; Ling CC
Med Phys; 1990; 17(5):826-32. PubMed ID: 2233568
[TBL] [Abstract][Full Text] [Related]
16. On the development of consensus values of reference dosimetry parameters for interstitial brachytherapy sources.
Chan GH; Nath R; Williamson JF;
Med Phys; 2004 May; 31(5):1040-5. PubMed ID: 15191290
[TBL] [Abstract][Full Text] [Related]
17. Tissue inhomogeneity correction for brachytherapy sources in a heterogeneous phantom with cylindrical symmetry.
Meigooni AS; Nath R
Med Phys; 1992; 19(2):401-7. PubMed ID: 1584139
[TBL] [Abstract][Full Text] [Related]
18. AAPM TG-43U1 formalism adaptation and monte carlo dosimetry simulations of multiple-radionuclide brachytherapy sources.
Nuttens VE; Lucas S
Med Phys; 2006 Apr; 33(4):1101-7. PubMed ID: 16696487
[TBL] [Abstract][Full Text] [Related]
19. A CT-based analytical dose calculation method for HDR 192Ir brachytherapy.
Poon E; Verhaegen F
Med Phys; 2009 Sep; 36(9):3982-94. PubMed ID: 19810471
[TBL] [Abstract][Full Text] [Related]
20. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.
Selvam TP; Sahoo S; Vishwakarma RS
Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]