BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 8357448)

  • 1. [Irregular erythrocyte antibody screening using gel-test. Analysis of 35,882 samples].
    Burin des Rosiers N; Nasr O
    Rev Fr Transfus Hemobiol; 1993 Jul; 36(4):391-9. PubMed ID: 8357448
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of recent techniques for detection of red blood cell antibodies in sera of reference samples, patients, pregnant women, and blood donors.
    de Castilho LM; Pellegrino J; Bechelli AP; Le Pennec PY; Mendes NF
    J Clin Lab Anal; 1996; 10(5):250-6. PubMed ID: 8887003
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Comparison of several methods for detecting anti-erythrocyte alloantibodies].
    Bencomo AA
    Sangre (Barc); 1990 Aug; 35(4):307-10. PubMed ID: 2125752
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Observations on antibody determination and differentiation with papain test erythrocytes using the gel centrifugation technique (ID-Microtyping System)].
    Strobel E; Wüllenweber J
    Infusionsther Transfusionsmed; 1995 Feb; 22(1):25-30. PubMed ID: 7727960
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Evaluation of the polyethyleneglycol antiglobulin test in the detection and identification of erythrocyte antibodies].
    Jiménez Marco MT; Hernández Maraver D; Rodríguez de la Rua A; de la Cámara Mendizábal C; Canales Albendea M; Jiménez Yuste V; Hernández Navarro F
    Sangre (Barc); 1998 Feb; 43(1):21-4. PubMed ID: 9577178
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Irregular antibodies. A comparative study of 2 series of 20,000 subjects: one with a conventional identification test, the other with gel-test].
    Trophilme C; Becker AM; Jaffard HP; Jaulin P
    Transfus Clin Biol; 1995; 2(3):189-99. PubMed ID: 7627358
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inhibition of serological reactions with enzyme-treated red cells by complement binding alloantibodies.
    Lown JA; Holland PA; Barr AL
    Vox Sang; 1984; 46(5):300-5. PubMed ID: 6730426
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the polyethylene glycol antiglobulin test and the use of enzymes in antibody detection and identification.
    Reisner R; Butler G; Bundy K; Moore SB
    Transfusion; 1996 Jun; 36(6):487-9. PubMed ID: 8669077
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Transfusion management of patients with red blood cell antibodies].
    Bujandrić NB; Grujić JN; Krga-Milanović MM
    Med Pregl; 2013; 66(11-12):491-6. PubMed ID: 24575638
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A solid-phase test using antiglobulin and enzyme-enhanced techniques for erythrocyte antibody screening during pregnancy.
    Sallander S; Shanwell A; Pegert S; Jakobsson L; Wiechel B
    Vox Sang; 1995; 68(1):22-6. PubMed ID: 7725668
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Micro-column affinity test and gel test: comparative study of two techniques for red cell antibody screening.
    Eichler H; Böhler A; Hastka J; Richter E; Kerowgan M; Goldmann SF
    Vox Sang; 1999; 77(3):154-8. PubMed ID: 10545852
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a solid-phase test for erythrocyte antibody screening of pregnant women, patients and blood donors.
    Sallander S; Shanwell A; Aqvist M
    Vox Sang; 1996; 71(4):221-5. PubMed ID: 8958646
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Two-stage papain-indirect antiglobulin test and LISS direct agglutination are not appropriate for pretransfusion screening for unexpected antibodies.
    Pereira A; Mazzara R; Gelabert A; Castillo R
    Haematologica; 1991; 76(6):475-8. PubMed ID: 1820984
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detection of red cell antibodies: comparison of two low ionic strength diluents.
    Skaik YA; Overfield J
    Br J Biomed Sci; 2006; 63(1):18-20. PubMed ID: 16613136
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Red cell antibodies and low ionic strength: a study with enzyme-linked antiglobulin test.
    Leikola J; Perkins HA
    Transfusion; 1980; 20(2):224-8. PubMed ID: 6768174
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of two column agglutination tests for red blood cell antibody testing.
    Sawierucha J; Posset M; Hähnel V; Johnson CL; Hutchinson JA; Ahrens N
    PLoS One; 2018; 13(12):e0210099. PubMed ID: 30596807
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Detection of irregular anti-erythrocyte antibodies using the indirect antiglobulin test in a low-ionic-strength medium. Immunohematology Group of the French Blood Transfusion Society].
    Mannessier L; Roubinet F
    Transfus Clin Biol; 1999 Jun; 6(3):174-9. PubMed ID: 10422210
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early primary immune response against erythrocytes: a case report.
    Albiero AL; Novaretti MC; Llacer PE; Chamone DA
    Transfus Med; 2003 Apr; 13(2):93-7. PubMed ID: 12694554
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Antibody determination and differentiation using papain treated test erythrocytes in the gel centrifugation technique (ID-Microtyping System)].
    Strobel E; Wüllenweber J
    Beitr Infusionsther Transfusionsmed; 1994; 32():153-5. PubMed ID: 9480073
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An antibody screening test based on the antiglobulin gel technique, pooled test cells, and plasma.
    Lillevang ST; Georgsen J; Kristensen T
    Vox Sang; 1994; 66(3):210-5. PubMed ID: 8036792
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.