These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 8358082)

  • 1. Software for counting cells and estimating structural volumes with the optical disector and fractionator.
    Bolender RP; Charleston JS
    Microsc Res Tech; 1993 Jul; 25(4):314-24. PubMed ID: 8358082
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Unbiased stereological estimation of the total number of neurons in thesubdivisions of the rat hippocampus using the optical fractionator.
    West MJ; Slomianka L; Gundersen HJ
    Anat Rec; 1991 Dec; 231(4):482-97. PubMed ID: 1793176
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A computer-aided analysis system for counting the synaptic numerical density based on disector technique].
    Shen L; Zhang L; Huang H; Liu H; Nan Y; Shang J; Liao H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2000 Jun; 17(2):167-9. PubMed ID: 12557772
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of frozen sections to determine neuronal number in the murine hippocampus and neocortex using the optical disector and optical fractionator.
    Bonthius DJ; McKim R; Koele L; Harb H; Karacay B; Mahoney J; Pantazis NJ
    Brain Res Brain Res Protoc; 2004 Nov; 14(1):45-57. PubMed ID: 15519951
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative morphology for biologists and computer scientists: I. Computer-aided tutorial for biological stereology (version 1.0).
    Bolender RP
    Microsc Res Tech; 1992 Jun; 21(4):338-46. PubMed ID: 1638052
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of cell death in the trochlear nucleus of the chick embryo: calibration of the optical disector counting method reveals systematic bias.
    Hatton WJ; von Bartheld CS
    J Comp Neurol; 1999 Jun; 409(2):169-86. PubMed ID: 10379913
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Particle detection, number estimation, and feature measurement in gene transfer studies: optical fractionator stereology integrated with digital image processing and analysis.
    King MA; Scotty N; Klein RL; Meyer EM
    Methods; 2002 Oct; 28(2):293-9. PubMed ID: 12413429
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computer assisted data collection for stereology: rationale and description of point counting stereology (PCS) software.
    Pentcheff ND; Bolender RP
    Microsc Res Tech; 1992 Jun; 21(4):347-54. PubMed ID: 1638053
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of neurons expressing androgen receptor and volume estimation of the basolateral nuclear group of the canine amygdaloid body.
    Jacobs C; Van Den Broeck W; Simoens P
    Brain Res Brain Res Protoc; 2005 Jul; 15(2):92-104. PubMed ID: 15922654
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Unbiased estimation of cell number using the automatic optical fractionator.
    Mouton PR; Phoulady HA; Goldgof D; Hall LO; Gordon M; Morgan D
    J Chem Neuroanat; 2017 Mar; 80():A1-A8. PubMed ID: 27988177
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative (stereological) study of the normal spermatogenesis in the adult monkey (Macaca fascicularis).
    Zhengwei Y; McLachlan RI; Bremner WJ; Wreford NG
    J Androl; 1997; 18(6):681-7. PubMed ID: 9432141
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Total number and mean size of alveoli in mammalian lung estimated using fractionator sampling and unbiased estimates of the Euler characteristic of alveolar openings.
    Hyde DM; Tyler NK; Putney LF; Singh P; Gundersen HJ
    Anat Rec A Discov Mol Cell Evol Biol; 2004 Mar; 277(1):216-26. PubMed ID: 14983516
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of the Cavalieri principle in volume estimation using laser confocal microscopy.
    Prakash YS; Smithson KG; Sieck GC
    Neuroimage; 1994 Nov; 1(4):325-33. PubMed ID: 9343582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimate of the total number of neurons and glial and endothelial cells in the rat spinal cord by means of the optical disector.
    Bjugn R; Gundersen HJ
    J Comp Neurol; 1993 Feb; 328(3):406-14. PubMed ID: 8440788
    [TBL] [Abstract][Full Text] [Related]  

  • 15. No change in neuron numbers in the dentate nucleus of patients with schizophrenia estimated with a new stereological method--the smooth fractionator.
    Andersen BB; Fabricius K; Gundersen HJ; Jelsing J; Stark AK
    J Anat; 2004 Oct; 205(4):313-21. PubMed ID: 15447690
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Primary visual cortex volume and total neuron number are reduced in schizophrenia.
    Dorph-Petersen KA; Pierri JN; Wu Q; Sampson AR; Lewis DA
    J Comp Neurol; 2007 Mar; 501(2):290-301. PubMed ID: 17226750
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The application of stereological methods for estimating structural parameters in the human heart.
    Tang Y; Nyengaard JR; Andersen JB; Baandrup U; Gundersen HJ
    Anat Rec (Hoboken); 2009 Oct; 292(10):1630-47. PubMed ID: 19714657
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurements of motoneuron somal volumes using laser confocal microscopy: comparisons with shape-based stereological estimations.
    Prakash YS; Smithson KG; Sieck GC
    Neuroimage; 1993 Sep; 1(2):95-107. PubMed ID: 9343561
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design-based estimation of neuronal number and individual neuronal volume in the rat hippocampus.
    Hosseini-Sharifabad M; Nyengaard JR
    J Neurosci Methods; 2007 May; 162(1-2):206-14. PubMed ID: 17368561
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Estimation of absolute microglial cell numbers in mouse fascia dentata using unbiased and efficient stereological cell counting principles.
    Wirenfeldt M; Dalmau I; Finsen B
    Glia; 2003 Nov; 44(2):129-39. PubMed ID: 14515329
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.