These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 835941)

  • 61. Comparison of ethanol and other drugs of abuse concentrations in whole blood stored in venoject glass and plastic and venosafe plastic evacuated tubes.
    Karinen R; Oiestad EL; Andresen W; Wethe G; Smith-Kielland A; Christophersen A
    J Anal Toxicol; 2010 Sep; 34(7):420-8. PubMed ID: 20822681
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Underestimation of unfractionated heparin therapy assessment due to platelet activation when using partial-draw (pediatric) citrate collection tubes.
    Desconclois C; Eschwège V; Proulle V; Boutekedjiret T; Dreyfus M; Toulon P
    Thromb Res; 2014 Nov; 134(5):1117-22. PubMed ID: 25248688
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Suggestions for an appropriate methodological approach for the validation of an evacuated blood collection tube made in plastic material including the effect of age.
    Foucher K; Toulon P; Schved JF; Polack B
    Thromb Haemost; 2004 Apr; 91(4):845-7. PubMed ID: 15045160
    [No Abstract]   [Full Text] [Related]  

  • 64. [A simple sprayer for the coating with EDTA of glass tubes for blood specimen collection].
    Tille D; D'Heureuse-Gerhardt R
    Z Med Labortech; 1975; 16(3):181. PubMed ID: 810987
    [No Abstract]   [Full Text] [Related]  

  • 65. Blood collection by evacuated tubes: the effects of the order of filling tubes on the serum values of potassium and lactate dehydrogenase.
    Alegre B; Miralles A; Martinez C; Otte A; Calero G
    Ann Biol Clin (Paris); 1989; 47(8):507. PubMed ID: 2604062
    [No Abstract]   [Full Text] [Related]  

  • 66. Choice of a satisfactory evacuated blood-collection tube for magnesium and zinc assays.
    Speich M; Gelot S
    Clin Chem; 1983 Aug; 29(8):1560-1. PubMed ID: 6872229
    [No Abstract]   [Full Text] [Related]  

  • 67. Elevated results in a vitamin B12 assay when using serum separator blood collection tubes.
    Lowrey I; Smith G
    Ann Clin Biochem; 2003 Sep; 40(Pt 5):560-2. PubMed ID: 14503995
    [TBL] [Abstract][Full Text] [Related]  

  • 68. [A combination stand for holding test tubes during the collection of blood].
    Kolesnikov VF
    Lab Delo; 1990; (3):73-4. PubMed ID: 1692918
    [No Abstract]   [Full Text] [Related]  

  • 69. N-nitrosamines--contaminants in blood-collection tubes.
    Lakritz L; Kimoto W
    Food Cosmet Toxicol; 1980 Feb; 18(1):31-4. PubMed ID: 7372207
    [No Abstract]   [Full Text] [Related]  

  • 70. Evaluation of Streck BCT and PAXgene Stabilised Blood Collection Tubes for Cell-Free Circulating DNA Studies in Plasma.
    Warton K; Yuwono NL; Cowley MJ; McCabe MJ; So A; Ford CE
    Mol Diagn Ther; 2017 Oct; 21(5):563-570. PubMed ID: 28631163
    [TBL] [Abstract][Full Text] [Related]  

  • 71. [Syringe sterilization in blood withdrawal].
    Reichenbach K
    Dtsch Med Wochenschr; 1971 Oct; 96(43):1697. PubMed ID: 5099203
    [No Abstract]   [Full Text] [Related]  

  • 72. Evacuated blood collection tubes.
    Collins CH
    Med Lab Sci; 1984 Jul; 41(3):307-8. PubMed ID: 6482700
    [No Abstract]   [Full Text] [Related]  

  • 73. [Use of polyethylene tubes for blood plasma collection under field conditions].
    Abrashkin-Zhuchkov RG; Gorbunova IuP; Suleĭmanov GD; Rybalka VM; Vaĭnshteĭn AM
    Lab Delo; 1978; (2):111. PubMed ID: 75993
    [No Abstract]   [Full Text] [Related]  

  • 74. Sterility of blood collection tubes.
    Medrek TJ; Wooley BC
    Ann Intern Med; 1977 Nov; 87(5):631-2. PubMed ID: 921097
    [No Abstract]   [Full Text] [Related]  

  • 75. Effects of blood collection tubes, including pediatric devices, on 16 common immunoassays.
    Wang S; Ho V; Roquemore-Goins A; Smith FA
    Clin Chem; 2006 May; 52(5):892-3. PubMed ID: 16638955
    [No Abstract]   [Full Text] [Related]  

  • 76. Glycerol lubricant: potential source of error in commercially prepared blood specimen tubes.
    Baum D
    Clin Chem; 1968 Jan; 14(1):73-4. PubMed ID: 5634642
    [No Abstract]   [Full Text] [Related]  

  • 77. Blood-collection tubes evaluated for use in measurement of some therapeutic drugs.
    Pou Clave L; Garcia Beltran L; Peremiquel Lluch M; Pascual Mostaza C; Schwartz Riera S
    Clin Chem; 1988 Apr; 34(4):795. PubMed ID: 3359634
    [No Abstract]   [Full Text] [Related]  

  • 78. Handling of and direct sampling from primary barcode-labeled pediatric tubes on Vitros clinical chemistry analyzers integrated into an enGen work cell.
    Demir AY; van Solinge WW; Kemperman H
    Clin Chem; 2005 May; 51(5):920-1. PubMed ID: 15855674
    [No Abstract]   [Full Text] [Related]  

  • 79. Comparison of glass and plastic blood collection tubes.
    Tetrault GA
    Arch Pathol Lab Med; 2006 Nov; 130(11):1600; author reply 1600. PubMed ID: 17076516
    [No Abstract]   [Full Text] [Related]  

  • 80. Possible sodium contamination of evacuated blood-collection tubes.
    Buzzee D
    Clin Chem; 1979 May; 25(5):814-5. PubMed ID: 436264
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.