These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
133 related articles for article (PubMed ID: 8359584)
1. A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Poitout V; Moatti-Sirat D; Reach G; Zhang Y; Wilson GS; Lemonnier F; Klein JC Diabetologia; 1993 Jul; 36(7):658-63. PubMed ID: 8359584 [TBL] [Abstract][Full Text] [Related]
2. Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination. Poitout V; Moatti-Sirat D; Reach G Biosens Bioelectron; 1992; 7(8):587-92. PubMed ID: 1457093 [TBL] [Abstract][Full Text] [Related]
3. A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm. Aussedat B; Thomé-Duret V; Reach G; Lemmonier F; Klein JC; Hu Y; Wilson GS Biosens Bioelectron; 1997; 12(11):1061-71. PubMed ID: 9451795 [TBL] [Abstract][Full Text] [Related]
4. Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Moatti-Sirat D; Capron F; Poitout V; Reach G; Bindra DS; Zhang Y; Wilson GS; Thévenot DR Diabetologia; 1992 Mar; 35(3):224-30. PubMed ID: 1373393 [TBL] [Abstract][Full Text] [Related]
5. A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. Updike SJ; Shults MC; Gilligan BJ; Rhodes RK Diabetes Care; 2000 Feb; 23(2):208-14. PubMed ID: 10868833 [TBL] [Abstract][Full Text] [Related]
6. Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats. Woderer S; Henninger N; Garthe CD; Kloetzer HM; Hajnsek M; Kamecke U; Gretz N; Kraenzlin B; Pill J Anal Chim Acta; 2007 Jan; 581(1):7-12. PubMed ID: 17386418 [TBL] [Abstract][Full Text] [Related]
7. Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man. Pickup JC; Claremont DJ; Shaw GW Acta Diabetol; 1993; 30(3):143-8. PubMed ID: 8111074 [TBL] [Abstract][Full Text] [Related]
8. Strategies for calibrating a subcutaneous glucose sensor. Velho G; Froguel P; Thevenot DR; Reach G Biomed Biochim Acta; 1989; 48(11-12):957-64. PubMed ID: 2700068 [TBL] [Abstract][Full Text] [Related]
9. In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor. Poitout V; Moatti D; Velho G; Reach G; Sternberg R; Thévenot DR; Bindra DS; Zhang YN; Wilson GS ASAIO Trans; 1991; 37(3):M298-300. PubMed ID: 1751159 [TBL] [Abstract][Full Text] [Related]
10. Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method. Choleau C; Klein JC; Reach G; Aussedat B; Demaria-Pesce V; Wilson GS; Gifford R; Ward WK Biosens Bioelectron; 2002 Aug; 17(8):647-54. PubMed ID: 12052350 [TBL] [Abstract][Full Text] [Related]
11. Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current. Choleau C; Klein JC; Reach G; Aussedat B; Demaria-Pesce V; Wilson GS; Gifford R; Ward WK Biosens Bioelectron; 2002 Aug; 17(8):641-6. PubMed ID: 12052349 [TBL] [Abstract][Full Text] [Related]
12. Enzymatic glucose sensors. Improved long-term performance in vitro and in vivo. Updike SJ; Shults MC; Rhodes RK; Gilligan BJ; Luebow JO; von Heimburg D ASAIO J; 1994; 40(2):157-63. PubMed ID: 8003752 [TBL] [Abstract][Full Text] [Related]
13. Initial evaluation of a 290-microm diameter subcutaneous glucose sensor: glucose monitoring with a biocompatible, flexible-wire, enzyme-based amperometric microsensor in diabetic and nondiabetic humans. Ishikawa M; Schmidtke DW; Raskin P; Quinn CA J Diabetes Complications; 1998; 12(6):295-301. PubMed ID: 9877461 [TBL] [Abstract][Full Text] [Related]
14. Continuous glucose monitoring in the free-moving rat. Thomé-Duret V; Aussedat B; Reach G; Gangnerau MN; Lemonnier F; Klein JC; Zhang Y; Hu Y; Wilson GS Metabolism; 1998 Jul; 47(7):799-803. PubMed ID: 9667224 [TBL] [Abstract][Full Text] [Related]
15. In situ calibration of implanted electrochemical glucose sensors. von Woedtke T; Rebrin K; Fischer U; Abel P; Wilke W; Vogt L; Albrecht G Biomed Biochim Acta; 1989; 48(11-12):943-52. PubMed ID: 2636839 [TBL] [Abstract][Full Text] [Related]
16. Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans. Gilligan BC; Shults M; Rhodes RK; Jacobs PG; Brauker JH; Pintar TJ; Updike SJ Diabetes Technol Ther; 2004 Jun; 6(3):378-86. PubMed ID: 15198842 [TBL] [Abstract][Full Text] [Related]
17. A miniaturized Nafion-based glucose sensor: in vitro and in vivo evaluation in dogs. Moussy F; Harrison DJ; Rajotte RV Int J Artif Organs; 1994 Feb; 17(2):88-94. PubMed ID: 8039946 [TBL] [Abstract][Full Text] [Related]
18. Calibration of a wearable glucose sensor. Schmidt FJ; Aalders AL; Schoonen AJ; Doorenbos H Int J Artif Organs; 1992 Jan; 15(1):55-61. PubMed ID: 1551730 [TBL] [Abstract][Full Text] [Related]
19. The role of the independent variable to glucose sensor calibration. Panteleon AE; Rebrin K; Steil GM Diabetes Technol Ther; 2003; 5(3):401-10. PubMed ID: 12828824 [TBL] [Abstract][Full Text] [Related]
20. Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration. Schmidtke DW; Heller A Anal Chem; 1998 May; 70(10):2149-55. PubMed ID: 9608851 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]