These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 83615)

  • 21. Lower chronic stimulation threshold in the carbon-tip than in the platinum-tip endocardial electrode: a randomized study.
    Thuesen L; Jensen PJ; Vejby-Christensen H; Mortensen PT; Thomsen PE
    Pacing Clin Electrophysiol; 1989 Oct; 12(10):1592-5. PubMed ID: 2477813
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A gastroesophageal electrode for atrial and ventricular pacing.
    McEneaney DJ; Cochrane DJ; Anderson JA; Adgey AA
    Pacing Clin Electrophysiol; 1997 Jul; 20(7):1815-25. PubMed ID: 9249837
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Atrial stimulation by means of floating electrodes: a multicenter experience. The Multicenter Study Group.
    Bongiorni MG; Bedendi N
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1977-81. PubMed ID: 1279583
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Impedance to transesophageal atrial pacing: significance regarding power sources.
    Kerr CR; Chung DC; Wickham G; Jameson M; Vorderbrugge S
    Pacing Clin Electrophysiol; 1989 Jun; 12(6):930-5. PubMed ID: 2472620
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Low polarization pacing lead for detecting the ventricular-evoked response.
    Bolz A; Hubmann M; Hardt R; Riedmüller J; Schaldach M
    Med Prog Technol; 1993; 19(3):129-37. PubMed ID: 8127278
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pacing threshold trends and variability in modern tined leads assessed using high resolution automatic measurements: conversion of pulse width into voltage thresholds.
    Danilovic D; Ohm OJ
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):567-87. PubMed ID: 10234710
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Relationship between pacemaker fibrillation thresholds and electrode area.
    Chen P; Myers GH; Parsonnet V; Chatterjee K; Katz P
    Med Instrum; 1975; 9(4):165-70. PubMed ID: 1143115
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pacing impedance variability in tined steroid eluting leads.
    Danilovic D; Ohm OJ
    Pacing Clin Electrophysiol; 1998 Jul; 21(7):1356-63. PubMed ID: 9670178
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Myocardial stimulation impedance: the effects of electrode, physiological, and stimulus variables.
    Tyers GF; Brownlee RR; Hughes HC; Shaffer CW; Williams EH; Kao RL
    Ann Thorac Surg; 1979 Jan; 27(1):63-9. PubMed ID: 453959
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Electrode surface areas, pulse duration and stimulation threshold. Acute and chronic study with endocardial unipolar electrodes (author's transl)].
    Antonioli GE; Grassi G; Baggioni GF; Bagni B
    G Ital Cardiol; 1977; 7(4):380-6. PubMed ID: 863147
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Small surface electrodes for cardiac pacing and their effect on the longevity of pacemakers.
    Netusil M
    Cor Vasa; 1972; 20(2):121-8. PubMed ID: 4499915
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Acute and chronic cycle length dependent increase in ventricular pacing threshold.
    Hook BG; Perlman RL; Callans DJ; Hanna MS; Kleiman RB; Flores BT; Marchlinski FE
    Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1437-44. PubMed ID: 1383954
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Paradigm shift in lead design.
    Irnich W
    Pacing Clin Electrophysiol; 1999 Sep; 22(9):1321-32. PubMed ID: 10527013
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Present day pacemakers for pulse generator exchange: is 3.5 V a sufficient nominal setting for the pulse amplitude? Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1824-7. PubMed ID: 8945049
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators.
    Swerdlow CD; Kass RM; Chen PS; Hwang C; Raissi S
    Circulation; 1994 Oct; 90(4):1840-6. PubMed ID: 7923670
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fully discharging phases. A new approach to biphasic waveforms for external defibrillation.
    Yamanouchi Y; Brewer JE; Olson KF; Mowrey KA; Mazgalev TN; Wilkoff BL; Tchou PJ
    Circulation; 1999 Aug; 100(8):826-31. PubMed ID: 10458718
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A low-threshold, non-dislocating endocardial electrode.
    Lagergren H; Edhag O; Wahlberg I
    J Thorac Cardiovasc Surg; 1976 Aug; 72(2):259-64. PubMed ID: 957741
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of local steroid elution on chronic pacing threshold and impedance of endocardial pacemaker leads.
    Schuchert A; Kuck KH
    Cardiology; 1993; 83(4):240-3. PubMed ID: 8281540
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The optimization of the pulse delivered by the pacemaker.
    Dressler L; Gruse G; von Knorre GH; Otte KB; Podszuz G; Richwien R; Schaedel H; Weber D; Weber D; Witte J
    Pacing Clin Electrophysiol; 1979 May; 2(3):282-8. PubMed ID: 95292
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Partial pacemaker recycling of implanted QRS-inhibited pulse generators.
    Sung RJ; Castellanos A; Thurer RJ; Myerburg RJ
    Pacing Clin Electrophysiol; 1978 Apr; 1(2):189-95. PubMed ID: 83633
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.