BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

224 related articles for article (PubMed ID: 8361896)

  • 1. [Hemolysis after bioprosthesis implantation in the mitral valve].
    Olszowska M; Hlawaty M; Pfitzner R; Tracz W
    Pol Tyg Lek; 1993 Jan 18-25; 48(3-4):83-4. PubMed ID: 8361896
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemolytic anemia following insertion of Ionescu-Shiley mitral valve bioprosthesis.
    Reddy SB; Pater JL; Pym J; Armstrong PW
    Can Med Assoc J; 1984 Dec; 131(12):1469-70. PubMed ID: 6498703
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemolytic anemia with porcine xenograft aortic and mitral valves.
    Magilligan DJ; Fisher E; Alam M
    J Thorac Cardiovasc Surg; 1980 Apr; 79(4):628-31. PubMed ID: 7359940
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Severe hemolytic anemia after mitral valvuloplasty].
    Michlmayr G; Knapp E; Scharfetter H; Simma HP; Gschnitzer F
    Schweiz Med Wochenschr; 1979 Jun; 109(26):976-8. PubMed ID: 462165
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Late-occurrence hemolytic anemia after mitral valve bioprosthesis. 2 cases].
    Piquemal R; Fauchier L; Regimbeau C; Babuty D; Neville P; Renard JP
    Arch Mal Coeur Vaiss; 1998 Jul; 91(7):879-81. PubMed ID: 9749180
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification.
    Gabbay S; Bortolotti U; Wasserman F; Factor S; Strom J; Frater RW
    J Thorac Cardiovasc Surg; 1984 Jun; 87(6):836-44. PubMed ID: 6727407
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Successful mitral valve replacement in multiple organ failure due to mechanical hemolytic anemia after mitral valve repair: a case report].
    Nakayama Y; Naitoh K; Kosako Y; Ohteki H; Natsuaki M; Itoh T
    Kyobu Geka; 1994 Aug; 47(9):744-7. PubMed ID: 8057563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Serious hemolytic anemia after mitral valvuloplasty].
    Michlmayr G; Knapp E; Scharfetter H; Simma HP; Braunsteiner H
    Acta Med Austriaca; 1979; 6(5):195-7. PubMed ID: 555215
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Haemolytic anaemia following implantation of the mitral annuloplasty ring: a case report].
    Goździk A; Skalik R; Pelczar M; Obremska M; Kustrzycki W
    Kardiol Pol; 2006 Jun; 64(6):619-21. PubMed ID: 16810582
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Repair of paravalvular leak after a third mitral valve replacement].
    Aizawa K; Tateishi A; Sakano Y; Kaminishi Y; Ohki S; Saito T; Konishi H; Kawada M; Misawa Y
    Kyobu Geka; 2007 Sep; 60(10):903-5. PubMed ID: 17877009
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Severe hemolytic anemia following purse-string valvuloplasty of the mitral valve].
    Brand B; Althaus U; Bucher U
    Schweiz Med Wochenschr; 1990 Mar; 120(13):456-61. PubMed ID: 2183349
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [A case of failure of mitroflow pericardial valve with severe hemolytic anemia].
    Ohkado A; Akiyama K; Hirota J; Shiina Y
    Kyobu Geka; 1995 Nov; 48(12):1013-5. PubMed ID: 8538101
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early failures of Ionescu-Shiley bioprosthesis after mitral valve replacement in children.
    Galioto Fm; Midgley FM; Kapur S; Perry LW; Watson DC; Shapiro SR; Ruckman RN; Scott LP
    J Thorac Cardiovasc Surg; 1982 Feb; 83(2):306-10. PubMed ID: 7057671
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemolysis after mitral valve repair: a report of five cases and literature review.
    Demirsoy E; Yilmaz O; Sirin G; Baran T; Tekin S; Sener D; Sonmez B
    J Heart Valve Dis; 2008 Jan; 17(1):24-30. PubMed ID: 18365565
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical hemolysis with the St. Jude heart valve without paravalvular leak.
    Barmada H; Starr A
    Med Prog Technol; 1994; 20(3-4):191-4. PubMed ID: 7877564
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reoperation for a patient 25 years after a Starr-Edwards ball mitral valve was installed.
    Ye Z; Shiono M; Sezai A; Inoue T; Hata M; Niino T; Goshima M; Nakamura T; Negishi N; Sezai Y
    Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):311-5. PubMed ID: 12472416
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Re-operation of a mitral porcine bioprosthesis 22-years after implantation].
    Soeda M; Hata H; Iida M; Kimura H
    Kyobu Geka; 2009 Feb; 62(2):149-51. PubMed ID: 19202937
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A case of 24 years longevity of an Ionescu-Shiley bioprosthesis in the mitral position.
    Watanabe Y; Ohkawa S; Yamabuki K; Tsuneoka H; Sugiyama N; Hiyama T
    Asian Cardiovasc Thorac Ann; 2006 Oct; 14(5):e96-8. PubMed ID: 17005876
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanism of hemolysis after mitral valve repair and new surgical management: prosthetic annuloplasty ring covered with autologous pericardium.
    Ishibashi N; Kasegawa H; Koyanagi T; Ida T
    J Heart Valve Dis; 2005 Sep; 14(5):588-91. PubMed ID: 16245496
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Severe hemolytic anemia after repair of primum septal defect and cleft mitral valve.
    Alehan D; Doğan R; Ozkutlu S; Elshershari H; Gümrük F
    Turk J Pediatr; 2001; 43(4):329-31. PubMed ID: 11765164
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]