These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 8365605)

  • 1. Artery weld strength after bipolar electrocoagulation is affected by electrolyte solutions around the artery.
    Harrison JD; Morris DL
    Gastrointest Endosc; 1993; 39(4):546-8. PubMed ID: 8365605
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Does bipolar electrocoagulation time affect vessel weld strength?
    Harrison JD; Morris DL
    Gut; 1991 Feb; 32(2):188-90. PubMed ID: 1864540
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An experimental study of optimal parameters for bipolar electrocoagulation.
    Dilley AV; Friend MA; Morris DL
    Gastrointest Endosc; 1995 Jul; 42(1):27-30. PubMed ID: 7557172
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bipolar impedance-controlled sealing of the pulmonary artery with SealSafe G3 electric current: determination of bursting pressures in an ex vivo model.
    Kirschbaum A; Kunz J; Steinfeldt T; Pehl A; Meyer C; Bartsch DK
    J Surg Res; 2014 Dec; 192(2):611-5. PubMed ID: 25128924
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An experimental study of optimal parameters for bipolar electrocoagulation.
    Dilley AV; Friend MG; Morris DL;
    Gastrointest Endosc; 1995 Jul; 42(1):27-30. PubMed ID: 28140055
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Randomized trial of normal saline solution injection versus bipolar electrocoagulation for treatment of patients with high-risk bleeding ulcers: is local tamponade enough?
    Laine L; Estrada R
    Gastrointest Endosc; 2002 Jan; 55(1):6-10. PubMed ID: 11756906
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries.
    Harold KL; Pollinger H; Matthews BD; Kercher KW; Sing RF; Heniford BT
    Surg Endosc; 2003 Aug; 17(8):1228-30. PubMed ID: 12799888
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surgical diathermy is not suitable for vascular tissue welding.
    Corner NB; Smith RE
    J R Army Med Corps; 1994 Oct; 140(3):127-31. PubMed ID: 8822065
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental comparison of endoscopic yttrium-aluminum-garnet laser, electrosurgery, and heater probe for canine gut arterial coagulation. Importance of compression and avoidance of erosion.
    Johnston JH; Jensen DM; Auth D
    Gastroenterology; 1987 May; 92(5 Pt 1):1101-8. PubMed ID: 3493938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.
    Yang CP; Cao JL; Yang RR; Guo HR; Li ZH; Guo HY; Shao YC; Liu GB
    J Laparoendosc Adv Surg Tech A; 2014 Feb; 24(2):72-6. PubMed ID: 24180354
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microwave energy compared with heater probe and BICAP in canine models of peptic ulcer hemorrhage.
    Michaletz PA; Judge D
    Gastroenterology; 1989 Sep; 97(3):676-84. PubMed ID: 2753328
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intelligent, impedance-regulated, pulsed coagulation in a porcine renal artery model.
    Wallwiener C; Wallwiener M; Neunhoeffer E; Menger M; Isaacson K; Zubke W
    Fertil Steril; 2007 Jul; 88(1):206-11. PubMed ID: 17462642
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thermal conduction, compression, and electrical current--an evaluation of major parameters of electrosurgical vessel sealing in a porcine in vitro model.
    Wallwiener CW; Rajab TK; Zubke W; Isaacson KB; Enderle M; Schäller D; Wallwiener M
    J Minim Invasive Gynecol; 2008; 15(5):605-10. PubMed ID: 18640881
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of Bone Wax Coated Bipolar Coagulation Forceps: Performance and Safety Assessment.
    Shi J; Wei W; Wang Z; Ren H; Jia C; Dong L; Li Z; Zhang J; Feng Y; Huang K; Li X; Chen J
    Front Surg; 2021; 8():816295. PubMed ID: 35127808
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Strength of laser vascular fusion: preliminary observations on the role of thrombus.
    Oz MC; Bass LS; Chuck RS; Johnson JP; Parangi S; Nowygrod R; Treat MR
    Lasers Surg Med; 1990; 10(4):393-5. PubMed ID: 2392020
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A randomized comparative study of laser photocoagulation, heater probe, and bipolar electrocoagulation in the treatment of actively bleeding ulcers.
    Hui WM; Ng MM; Lok AS; Lai CL; Lau YN; Lam SK
    Gastrointest Endosc; 1991; 37(3):299-304. PubMed ID: 2070978
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of the effect of monopolar and bipolar cauterization on skeletonized, dissected internal thoracic arteries.
    Yoshida H; Wu MH; Kouchi Y; Onuki Y; Shi Q; Sauvage LR
    J Thorac Cardiovasc Surg; 1995 Aug; 110(2):504-10. PubMed ID: 7637368
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of argon laser photocoagulation and bipolar electrocoagulation for endoscopic hemostasis in the canine colon.
    Jensen DM; Machicado GA; Tapia J; Mautner W
    Gastroenterology; 1982 Oct; 83(4):830-5. PubMed ID: 7049825
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Experimental endovascular electrocoagulation. Use of alternating current and a bipolar electrode (preliminary study) (author's transl)].
    Brunelle F; Kunstlinger F; Quillard J; Roche A; Doyon D
    J Radiol; 1979 Feb; 60(2):129-32. PubMed ID: 490462
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of the optimal technique for bipolar electrocoagulation treatment. An experimental evaluation of the BICAP and Gold probes.
    Laine L
    Gastroenterology; 1991 Jan; 100(1):107-12. PubMed ID: 1983812
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.