These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 8381938)

  • 1. Haemodialysis recirculation detected by the three-sample method is an artefact.
    Tattersall JE; Farrington K; Raniga PD; Thompson H; Tomlinson C; Aldridge C; Greenwood RN
    Nephrol Dial Transplant; 1993; 8(1):60-3. PubMed ID: 8381938
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemodialysis access recirculation measured by ultrasound dilution.
    Depner TA; Krivitski NM; MacGibbon D
    ASAIO J; 1995; 41(3):M749-53. PubMed ID: 8573907
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Non-invasive determination of recirculation in the patient on dialysis.
    Hester RL; Ashcraft D; Curry E; Bower J
    ASAIO J; 1992; 38(3):M190-3. PubMed ID: 1457846
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Peripheral venous blood is not the appropriate specimen to determine the amount of recirculation during hemodialysis.
    Van Stone JC
    ASAIO J; 1996; 42(1):41-5. PubMed ID: 8808457
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fistula dysfunction: effect on rapid hemodialysis.
    Collins DM; Lambert MB; Middleton JP; Proctor RK; Davidson CJ; Newman GE; Schwab SJ
    Kidney Int; 1992 May; 41(5):1292-6. PubMed ID: 1614044
    [TBL] [Abstract][Full Text] [Related]  

  • 6. All currently used measurements of recirculation in blood access by chemical methods are flawed due to intradialytic disequilibrium or recirculation at low flow.
    Twardowski ZJ; Van Stone JC; Haynie JD
    Am J Kidney Dis; 1998 Dec; 32(6):1046-58. PubMed ID: 9856523
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new method of post-dialysis blood urea sampling: the 'stop dialysate flow' method.
    Geddes CC; Traynor J; Walbaum D; Fox JG; Mactier RA
    Nephrol Dial Transplant; 2000 Apr; 15(4):517-23. PubMed ID: 10727547
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and precision of access recirculation measurements by the hemodynamic recirculation monitor.
    Lindsay RM; Blake PG; Malek P; Posen G; Martin B; Bradfield E
    Am J Kidney Dis; 1998 Feb; 31(2):242-9. PubMed ID: 9469494
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Urea concentration gradients during conventional hemodialysis.
    Sombolos K; Natse T; Zoumbaridis N; Mavromatidis K; Karagianni A; Scandalos J; Fitili C
    Am J Kidney Dis; 1996 May; 27(5):673-9. PubMed ID: 8629627
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Theoretical and practical issues in recirculation; assessment of vascular access.
    Schneditz D
    EDTNA ERCA J; 1998; 24(2):3-6. PubMed ID: 10392054
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of methods for the measurement of hemodialysis access recirculation.
    Basile C; Ruggieri G; Vernaglione L; Montanaro A; Giordano R
    J Nephrol; 2003; 16(6):908-13. PubMed ID: 14736020
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiopulmonary recirculation in dialysis. An underrecognized phenomenon.
    Schneditz D; Polaschegg HD; Levin NW; Cu GA; Morris AT; Krämer M; Daugirdas JT; Kaufman AM
    ASAIO J; 1992; 38(3):M194-6. PubMed ID: 1457847
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Variable blood pump flow rates and the effect on recirculation.
    Hasbargen JA; Bergstrom RJ
    Clin Nephrol; 1994 Nov; 42(5):322-6. PubMed ID: 7851034
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemodialysis blood access flow rates can be estimated accurately from on-line dialysate urea measurements and the knowledge of effective dialyzer urea clearance.
    Lindsay RM; Sternby J; Olde B; Persson R; Thatcher ME; Sargent K
    Clin J Am Soc Nephrol; 2006 Sep; 1(5):960-4. PubMed ID: 17699313
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Potassium-based dilutional method to measure hemodialysis access recirculation.
    Brancaccio D; Tessitore N; Carpani P; Gammaro L; Losi B; Zoni U; Maschio G; Gallieni M
    Int J Artif Organs; 2001 Sep; 24(9):606-13. PubMed ID: 11693416
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The relationship of recirculation to access blood flow.
    Besarab A; Sherman R
    Am J Kidney Dis; 1997 Feb; 29(2):223-9. PubMed ID: 9016893
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Factors responsible for increased percent recirculation in arterio-venous fistula among the haemodialysis patients.
    Mahbub T; Chowdhury MN; Jahan F; Islam MN; Khan FM; Sikder NH; Rahman M
    Bangladesh Med Res Counc Bull; 2013 Apr; 39(1):28-33. PubMed ID: 23923409
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Haemodialysis recirculation measured using a femoral artery sample.
    Buur T; Will EJ
    Nephrol Dial Transplant; 1994; 9(4):395-8. PubMed ID: 8084453
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of haemodialysis recirculation and access blood flow measured by thermodilution.
    Schneditz D; Wang E; Levin NW
    Nephrol Dial Transplant; 1999 Feb; 14(2):376-83. PubMed ID: 10069192
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Recirculation measures with urea and mannitol during hemodialysis.
    Kirschbaum B
    Artif Organs; 1994 Aug; 18(8):547-51. PubMed ID: 7993189
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.