124 related articles for article (PubMed ID: 8394806)
1. Capillary zone electrophoresis of biological substances with fused silica capillaries having zero or constant electroosmotic flow.
Smith JT; el Rassi Z
Electrophoresis; 1993; 14(5-6):396-406. PubMed ID: 8394806
[TBL] [Abstract][Full Text] [Related]
2. Fused-silica capillaries with surface-bound dextran layer crosslinked with diepoxypolyethylene glycol for capillary electrophoresis of biological substances at reduced electroosmotic flow.
Mechref Y; el Rassi Z
Electrophoresis; 1995 Apr; 16(4):617-24. PubMed ID: 7588534
[TBL] [Abstract][Full Text] [Related]
3. Capillary zone electrophoresis of proteins with fused-silica capillaries having polymers and surfactants adsorbed onto surfactant moieties previously covalently bound to the capillary column surface.
Yang C; El Rassi Z
Electrophoresis; 1998 Oct; 19(13):2278-84. PubMed ID: 9788309
[TBL] [Abstract][Full Text] [Related]
4. Polyethyleneimine-bonded phases in the separation of proteins by capillary electrophoresis.
Towns JK; Regnier FE
J Chromatogr; 1990 Sep; 516(1):69-78. PubMed ID: 1962785
[TBL] [Abstract][Full Text] [Related]
5. External electric field control of electroosmotic flow in non-coated and coated fused-silica capillaries and its application for capillary electrophoretic separations of peptides.
Kasicka V; Prusík Z; Sázelová P; Chiari M; Miksík I; Deyl Z
J Chromatogr B Biomed Sci Appl; 2000 Apr; 741(1):43-54. PubMed ID: 10839131
[TBL] [Abstract][Full Text] [Related]
6. Novel polyamine coating providing non-covalent deactivation and reversed electroosmotic flow of fused-silica capillaries for capillary electrophoresis.
Hardenborg E; Zuberovic A; Ullsten S; Söderberg L; Heldin E; Markides KE
J Chromatogr A; 2003 Jun; 1003(1-2):217-21. PubMed ID: 12899312
[TBL] [Abstract][Full Text] [Related]
7. Hydrolytically stable cellulose-derivative coatings for capillary electrophoresis of peptides, proteins and glycoconjugates.
Huang M; Plocek J; Novotny MV
Electrophoresis; 1995 Mar; 16(3):396-401. PubMed ID: 7607173
[TBL] [Abstract][Full Text] [Related]
8. Control of electroosmotic flow and wall interactions in capillary electrophoresis capillaries by photografted zwitterionic polymer surface layers.
Jiang W; Awasum JN; Irgum K
Anal Chem; 2003 Jun; 75(11):2768-74. PubMed ID: 12948148
[TBL] [Abstract][Full Text] [Related]
9. Capillary electrophoresis of peptides and proteins in fused-silica capillaries coated with derivatized polystyrene nanoparticles.
Kleindienst G; Huber CG; Gjerde DT; Yengoyan L; Bonn GK
Electrophoresis; 1998 Feb; 19(2):262-9. PubMed ID: 9548289
[TBL] [Abstract][Full Text] [Related]
10. Capillary electrophoresis of peptides and proteins at neutral pH in capillaries covalently coated with polyethyleneimine.
Figeys D; Aebersold R
J Chromatogr B Biomed Sci Appl; 1997 Jul; 695(1):163-8. PubMed ID: 9271140
[TBL] [Abstract][Full Text] [Related]
11. Moderation of the electroosmotic flow in capillary electrophoresis by chemical modification of the capillary surface with tentacle-like oligourethanes.
König S; Welsch T
J Chromatogr A; 2000 Oct; 894(1-2):79-88. PubMed ID: 11100850
[TBL] [Abstract][Full Text] [Related]
12. Electroosmotic flow changes due to interactions of background electrolyte counter-ions with polyethyleneimine coating in capillary zone electrophoresis of proteins.
Spanilá M; Pazourek J; Havel J
J Sep Sci; 2006 Sep; 29(14):2234-40. PubMed ID: 17069254
[TBL] [Abstract][Full Text] [Related]
13. Tuning capillary surface properties by charged polymeric coatings.
Sola L; Chiari M
J Chromatogr A; 2015 Oct; 1414():173-81. PubMed ID: 26338212
[TBL] [Abstract][Full Text] [Related]
14. Electrokinetic separation of peptides and proteins using a polyvinylamine-coated capillary with UV and ESI-MS detection.
Wu Y; Xie J; Wang F; Chen Z
J Sep Sci; 2008 Mar; 31(5):814-23. PubMed ID: 18293421
[TBL] [Abstract][Full Text] [Related]
15. Capillary electrophoresis using core-based hyperbranched polyethyleneimine (CHPEI) static-coated capillaries.
Boonyakong C; Tucker SA
J Sep Sci; 2009 Oct; 32(20):3489-96. PubMed ID: 19750504
[TBL] [Abstract][Full Text] [Related]
16. Quaternary ammonium substituted agarose as surface coating for capillary electrophoresis.
Ullsten S; Söderberg L; Folestad S; Markides KE
Analyst; 2004 May; 129(5):410-5. PubMed ID: 15116232
[TBL] [Abstract][Full Text] [Related]
17. [The preparation of chemical-bonded hyperbranched polymer coated column for capillary electrophoresis and their application to separation of basic proteins].
Shou C; Zhang Z; Zhou C; Zhao C; Li G; Chen L
Se Pu; 2004 May; 22(3):273-6. PubMed ID: 15712917
[TBL] [Abstract][Full Text] [Related]
18. Hydrolytically stable amino-silica glass coating material for manipulation of the electroosmotic flow in capillary electrophoresis.
Guo Y; Imahori GA; Colón LA
J Chromatogr A; 1996 Sep; 744(1-2):17-29. PubMed ID: 8843661
[TBL] [Abstract][Full Text] [Related]
19. Capillary electrochromatography with novel stationary phases. I. Preparation and characterization of octadecylsulfonated silica.
Zhang M; El Rassi Z
Electrophoresis; 1998 Sep; 19(12):2068-72. PubMed ID: 9761183
[TBL] [Abstract][Full Text] [Related]
20. Studies in capillary zone electrophoresis with a post-column multiple capillary device for fraction collection and stepwise increase in electroosmotic flow during analysis.
Nashabeh W; Smith JT; el Rassi Z
Electrophoresis; 1993; 14(5-6):407-16. PubMed ID: 8354225
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]