258 related articles for article (PubMed ID: 8403717)
1. Comparative SPECT study of stroke using Tc-99m ECD, I-123 IMP, and Tc-99m HMPAO.
Matsuda H; Li YM; Higashi S; Sumiya H; Tsuji S; Kinuya K; Hisada K; Yamashita J
Clin Nucl Med; 1993 Sep; 18(9):754-8. PubMed ID: 8403717
[TBL] [Abstract][Full Text] [Related]
2. [A comparative study of the quality of SPECT images obtained by 123I-IMP, 99mTc-HMPAO and 99mTc-ECD].
Odano I; Ohkubo M; Takahashi M; Noguchi E; Ohtaki H; Kasahara T; Shibaki M; Hatano M
Kaku Igaku; 1997 Mar; 34(3):189-94. PubMed ID: 9136527
[TBL] [Abstract][Full Text] [Related]
3. Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry.
Ito H; Inoue K; Goto R; Kinomura S; Taki Y; Okada K; Sato K; Sato T; Kanno I; Fukuda H
Ann Nucl Med; 2006 Feb; 20(2):131-8. PubMed ID: 16615422
[TBL] [Abstract][Full Text] [Related]
4. [Comparison of cerebral vasoreactivity to acetazolamide in normal volunteer among 123I-IMP, 99mTc-ECD and 99mTc-HMPAO].
Makino K; Masuda Y; Gotoh S
Kaku Igaku; 1996 May; 33(5):551-5. PubMed ID: 8699624
[TBL] [Abstract][Full Text] [Related]
5. Technetium-99m-HMPAO, technetium-99m-ECD and iodine-123-IMP cerebral blood flow measurements with pharmacological interventions in primates.
Dormehl IC; Oliver DW; Langen KJ; Hugo N; Croft SA
J Nucl Med; 1997 Dec; 38(12):1897-901. PubMed ID: 9430465
[TBL] [Abstract][Full Text] [Related]
6. SPECT images of technetium-99m-ethyl cysteinate dimer in cerebrovascular diseases: comparison with other cerebral perfusion tracers and PET.
Tsuchida T; Nishizawa S; Yonekura Y; Sadato N; Iwasaki Y; Fujita T; Matoba N; Magata Y; Tamaki N; Konishi J
J Nucl Med; 1994 Jan; 35(1):27-31. PubMed ID: 8271056
[TBL] [Abstract][Full Text] [Related]
7. "Luxury perfusion" with 99mTc-HMPAO and 123I-IMP SPECT imaging during the subacute phase of stroke.
Moretti JL; Defer G; Cinotti L; Cesaro P; Degos JD; Vigneron N; Ducassou D; Holman BL
Eur J Nucl Med; 1990; 16(1):17-22. PubMed ID: 2307169
[TBL] [Abstract][Full Text] [Related]
8. Intra-individual differences between technetium-99m-HMPAO and technetium-99m-ECD in the normal medial temporal lobe.
Oku N; Matsumoto M; Hashikawa K; Moriwaki H; Ishida M; Seike Y; Terakawa H; Watanabe Y; Uehara T; Nishimura T
J Nucl Med; 1997 Jul; 38(7):1109-11. PubMed ID: 9225799
[TBL] [Abstract][Full Text] [Related]
9. [Quantitation of regional cerebral blood flow by single photon emission computed tomography of CBF-tracer combined with whole-brain CBF: a comparison between 123I-IMP and 99mTc-HMPAO in healthy volunteers].
Isaka Y; Imaizumi M; Ashida K; Ohe Y; Okamoto M; Abe T; Tanaka S
Kaku Igaku; 1994 May; 31(5):423-9. PubMed ID: 8028214
[TBL] [Abstract][Full Text] [Related]
10. [Intrasubject comparison of regional cerebral blood flow between N-isopropyl-p-[123I]iodoamphetamine SPECT and 99mTc-hexamethylpropyleneamine oxime SPECT in patients with ischemic cerebrovascular disease].
Isaka Y; Yoshikawa T; Ohe Y; Nakayama H; Abe T; Ashida K; Imaizumi M; Tanaka S
Kaku Igaku; 1995 Feb; 32(2):131-8. PubMed ID: 7715098
[TBL] [Abstract][Full Text] [Related]
11. Regional differences between 99mTc-ECD and 99mTc-HMPAO SPET in perfusion changes with age and gender in healthy adults.
Inoue K; Nakagawa M; Goto R; Kinomura S; Sato T; Sato K; Fukuda H
Eur J Nucl Med Mol Imaging; 2003 Nov; 30(11):1489-97. PubMed ID: 14579088
[TBL] [Abstract][Full Text] [Related]
12. Comparison of technetium-99m-HMPAO and technetium-99m-ECD cerebral SPECT images in Alzheimer's disease.
van Dyck CH; Lin CH; Smith EO; Wisniewski G; Cellar J; Robinson R; Narayan M; Bennett A; Delaney RC; Bronen RA; Hoffer PB
J Nucl Med; 1996 Nov; 37(11):1749-55. PubMed ID: 8917168
[TBL] [Abstract][Full Text] [Related]
13. [Usefulness of 99mTc-ECD SPECT in diseases of the central nerve system: special reference to a comparison with 123I-IMP and 99mTc-HM-PAO SPECT].
Ono S; Yanagimoto S; Mimura H; Otsuka N; Nagai K; Morita K; Tomomitsu T; Muranaka A; Watanabe A; Ishii R
Kaku Igaku; 1992 Dec; 29(12):1429-40. PubMed ID: 1491488
[TBL] [Abstract][Full Text] [Related]
14. Early and delayed brain SPECT with technetium-99m-ECD and iodine-123-IMP in subacute strokes.
Moretti JL; Tamgac F; Weinmann P; Caillat-Vigneron N; Belin CA; Cesaro P; Holman BL; Defer G
J Nucl Med; 1994 Sep; 35(9):1444-9. PubMed ID: 8071689
[TBL] [Abstract][Full Text] [Related]
15. Improvement of brain SPECT by stabilization of Tc-99m-HMPAO with methylene blue or cobalt chloride. Comparison with Tc-99m-ECD.
Barthel H; Kämpfer I; Seese A; Dannenberg C; Kluge R; Burchert W; Knapp WH
Nuklearmedizin; 1999 Apr; 38(3):80-4. PubMed ID: 10320993
[TBL] [Abstract][Full Text] [Related]
16. An alternative approach to estimation of the brain perfusion index for measurement of cerebral blood flow using technetium-99m compounds.
Murase K; Inoue T; Fujioka H; Ishimaru Y; Akamune A; Yamamoto Y; Mochizuki T; Ikezoe J
Eur J Nucl Med; 1999 Oct; 26(10):1333-9. PubMed ID: 10541833
[TBL] [Abstract][Full Text] [Related]
17. [Difference in the distribution of 123I-IMP and 99mTc-HMPAO in the striatum--comparison with 15O-PET].
Otsuka M; Ichiya Y; Kuwabara Y; Sasaki M; Akashi Y; Yoshida T; Fukumura T; Masuda K
Kaku Igaku; 1993 Apr; 30(4):389-95. PubMed ID: 8315889
[TBL] [Abstract][Full Text] [Related]
18. [Nuclear medicine for general radiologists: clinical application of brain SPECT].
Kuwabara Y
Nihon Igaku Hoshasen Gakkai Zasshi; 2000 Oct; 60(12):671-7. PubMed ID: 11155695
[TBL] [Abstract][Full Text] [Related]
19. Comparison of I-123 IMP and Tc-99m HMPAO SPECT studies with PET in dementia.
Kuwabara Y; Ichiya Y; Otsuka M; Tahara T; Fukumura T; Gunasekera R; Ichimiya A; Masuda K
Ann Nucl Med; 1990 Nov; 4(3):75-82. PubMed ID: 2083138
[TBL] [Abstract][Full Text] [Related]
20. Quantitative 123I IMP and 99mTc HMPAO imaging in the dog following cocaine administration.
Susskind H; Weber DA; Ivanovic M; Wong CT; DeHaan CE; Gavin PR
Nucl Med Biol; 1996 Apr; 23(3):343-52. PubMed ID: 8782246
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]