These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
254 related articles for article (PubMed ID: 8403717)
1. Comparative SPECT study of stroke using Tc-99m ECD, I-123 IMP, and Tc-99m HMPAO. Matsuda H; Li YM; Higashi S; Sumiya H; Tsuji S; Kinuya K; Hisada K; Yamashita J Clin Nucl Med; 1993 Sep; 18(9):754-8. PubMed ID: 8403717 [TBL] [Abstract][Full Text] [Related]
2. [A comparative study of the quality of SPECT images obtained by 123I-IMP, 99mTc-HMPAO and 99mTc-ECD]. Odano I; Ohkubo M; Takahashi M; Noguchi E; Ohtaki H; Kasahara T; Shibaki M; Hatano M Kaku Igaku; 1997 Mar; 34(3):189-94. PubMed ID: 9136527 [TBL] [Abstract][Full Text] [Related]
3. Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry. Ito H; Inoue K; Goto R; Kinomura S; Taki Y; Okada K; Sato K; Sato T; Kanno I; Fukuda H Ann Nucl Med; 2006 Feb; 20(2):131-8. PubMed ID: 16615422 [TBL] [Abstract][Full Text] [Related]
4. [Comparison of cerebral vasoreactivity to acetazolamide in normal volunteer among 123I-IMP, 99mTc-ECD and 99mTc-HMPAO]. Makino K; Masuda Y; Gotoh S Kaku Igaku; 1996 May; 33(5):551-5. PubMed ID: 8699624 [TBL] [Abstract][Full Text] [Related]
5. Technetium-99m-HMPAO, technetium-99m-ECD and iodine-123-IMP cerebral blood flow measurements with pharmacological interventions in primates. Dormehl IC; Oliver DW; Langen KJ; Hugo N; Croft SA J Nucl Med; 1997 Dec; 38(12):1897-901. PubMed ID: 9430465 [TBL] [Abstract][Full Text] [Related]
7. "Luxury perfusion" with 99mTc-HMPAO and 123I-IMP SPECT imaging during the subacute phase of stroke. Moretti JL; Defer G; Cinotti L; Cesaro P; Degos JD; Vigneron N; Ducassou D; Holman BL Eur J Nucl Med; 1990; 16(1):17-22. PubMed ID: 2307169 [TBL] [Abstract][Full Text] [Related]
8. Intra-individual differences between technetium-99m-HMPAO and technetium-99m-ECD in the normal medial temporal lobe. Oku N; Matsumoto M; Hashikawa K; Moriwaki H; Ishida M; Seike Y; Terakawa H; Watanabe Y; Uehara T; Nishimura T J Nucl Med; 1997 Jul; 38(7):1109-11. PubMed ID: 9225799 [TBL] [Abstract][Full Text] [Related]
9. [Quantitation of regional cerebral blood flow by single photon emission computed tomography of CBF-tracer combined with whole-brain CBF: a comparison between 123I-IMP and 99mTc-HMPAO in healthy volunteers]. Isaka Y; Imaizumi M; Ashida K; Ohe Y; Okamoto M; Abe T; Tanaka S Kaku Igaku; 1994 May; 31(5):423-9. PubMed ID: 8028214 [TBL] [Abstract][Full Text] [Related]
10. [Intrasubject comparison of regional cerebral blood flow between N-isopropyl-p-[123I]iodoamphetamine SPECT and 99mTc-hexamethylpropyleneamine oxime SPECT in patients with ischemic cerebrovascular disease]. Isaka Y; Yoshikawa T; Ohe Y; Nakayama H; Abe T; Ashida K; Imaizumi M; Tanaka S Kaku Igaku; 1995 Feb; 32(2):131-8. PubMed ID: 7715098 [TBL] [Abstract][Full Text] [Related]
11. Regional differences between 99mTc-ECD and 99mTc-HMPAO SPET in perfusion changes with age and gender in healthy adults. Inoue K; Nakagawa M; Goto R; Kinomura S; Sato T; Sato K; Fukuda H Eur J Nucl Med Mol Imaging; 2003 Nov; 30(11):1489-97. PubMed ID: 14579088 [TBL] [Abstract][Full Text] [Related]
12. Comparison of technetium-99m-HMPAO and technetium-99m-ECD cerebral SPECT images in Alzheimer's disease. van Dyck CH; Lin CH; Smith EO; Wisniewski G; Cellar J; Robinson R; Narayan M; Bennett A; Delaney RC; Bronen RA; Hoffer PB J Nucl Med; 1996 Nov; 37(11):1749-55. PubMed ID: 8917168 [TBL] [Abstract][Full Text] [Related]
13. [Usefulness of 99mTc-ECD SPECT in diseases of the central nerve system: special reference to a comparison with 123I-IMP and 99mTc-HM-PAO SPECT]. Ono S; Yanagimoto S; Mimura H; Otsuka N; Nagai K; Morita K; Tomomitsu T; Muranaka A; Watanabe A; Ishii R Kaku Igaku; 1992 Dec; 29(12):1429-40. PubMed ID: 1491488 [TBL] [Abstract][Full Text] [Related]
14. Early and delayed brain SPECT with technetium-99m-ECD and iodine-123-IMP in subacute strokes. Moretti JL; Tamgac F; Weinmann P; Caillat-Vigneron N; Belin CA; Cesaro P; Holman BL; Defer G J Nucl Med; 1994 Sep; 35(9):1444-9. PubMed ID: 8071689 [TBL] [Abstract][Full Text] [Related]
15. Improvement of brain SPECT by stabilization of Tc-99m-HMPAO with methylene blue or cobalt chloride. Comparison with Tc-99m-ECD. Barthel H; Kämpfer I; Seese A; Dannenberg C; Kluge R; Burchert W; Knapp WH Nuklearmedizin; 1999 Apr; 38(3):80-4. PubMed ID: 10320993 [TBL] [Abstract][Full Text] [Related]
16. An alternative approach to estimation of the brain perfusion index for measurement of cerebral blood flow using technetium-99m compounds. Murase K; Inoue T; Fujioka H; Ishimaru Y; Akamune A; Yamamoto Y; Mochizuki T; Ikezoe J Eur J Nucl Med; 1999 Oct; 26(10):1333-9. PubMed ID: 10541833 [TBL] [Abstract][Full Text] [Related]
17. [Difference in the distribution of 123I-IMP and 99mTc-HMPAO in the striatum--comparison with 15O-PET]. Otsuka M; Ichiya Y; Kuwabara Y; Sasaki M; Akashi Y; Yoshida T; Fukumura T; Masuda K Kaku Igaku; 1993 Apr; 30(4):389-95. PubMed ID: 8315889 [TBL] [Abstract][Full Text] [Related]
18. [Nuclear medicine for general radiologists: clinical application of brain SPECT]. Kuwabara Y Nihon Igaku Hoshasen Gakkai Zasshi; 2000 Oct; 60(12):671-7. PubMed ID: 11155695 [TBL] [Abstract][Full Text] [Related]
19. Comparison of I-123 IMP and Tc-99m HMPAO SPECT studies with PET in dementia. Kuwabara Y; Ichiya Y; Otsuka M; Tahara T; Fukumura T; Gunasekera R; Ichimiya A; Masuda K Ann Nucl Med; 1990 Nov; 4(3):75-82. PubMed ID: 2083138 [TBL] [Abstract][Full Text] [Related]
20. Quantitative 123I IMP and 99mTc HMPAO imaging in the dog following cocaine administration. Susskind H; Weber DA; Ivanovic M; Wong CT; DeHaan CE; Gavin PR Nucl Med Biol; 1996 Apr; 23(3):343-52. PubMed ID: 8782246 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]