259 related articles for article (PubMed ID: 8404199)
1. Relationship of thermodilution cardiac output to metabolic measurements and mixed venous oxygen saturation.
Mahutte CK; Jaffe MB; Sasse SA; Chen PA; Berry RB; Sassoon CS
Chest; 1993 Oct; 104(4):1236-42. PubMed ID: 8404199
[TBL] [Abstract][Full Text] [Related]
2. Cardiac output from carbon dioxide production and arterial and venous oximetry.
Mahutte CK; Jaffe MB; Sassoon CS; Wong DH
Crit Care Med; 1991 Oct; 19(10):1270-7. PubMed ID: 1914484
[TBL] [Abstract][Full Text] [Related]
3. Comparison between cardiac output measured by thermodilution technique and calculated by O2 and modified CO2 Fick methods using a new metabolic monitor.
Brandi LS; Bertolini R; Pieri M; Giunta F; Calafà M
Intensive Care Med; 1997 Aug; 23(8):908-15. PubMed ID: 9310812
[TBL] [Abstract][Full Text] [Related]
4. Oxygen Fick and modified carbon dioxide Fick cardiac outputs.
Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS
Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981
[TBL] [Abstract][Full Text] [Related]
5. Effect of measurement errors on cardiac output calculated with O2 and modified CO2 Fick methods.
Mahutte CK; Jaffe MB
J Clin Monit; 1995 Mar; 11(2):99-108. PubMed ID: 7760094
[TBL] [Abstract][Full Text] [Related]
6. Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake.
Nakanishi N; Yoshioka T; Okano Y; Nishimura T
Chest; 1993 Aug; 104(2):419-26. PubMed ID: 8339630
[TBL] [Abstract][Full Text] [Related]
7. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
Chang AC; Kulik TJ; Hickey PR; Wessel DL
Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
[TBL] [Abstract][Full Text] [Related]
8. Feasibility of continuous oxygen delivery and cardiac output measurement by application of the Fick principle.
Feustel PJ; Perkins RJ; Oppenlander JE; Stratton HH; Cohen IL
Am J Respir Crit Care Med; 1994 Mar; 149(3 Pt 1):751-8. PubMed ID: 8118646
[TBL] [Abstract][Full Text] [Related]
9. Comparison of indirect calorimetry and thermodilution cardiac output measurement in children.
Capderou A; Douguet D; Losay J; Zelter M
Am J Respir Crit Care Med; 1997 Jun; 155(6):1930-4. PubMed ID: 9196098
[TBL] [Abstract][Full Text] [Related]
10. Continual trending of Fick variables in the critically ill patient.
Quinn TJ; Weissman C; Kemper M
Chest; 1991 Mar; 99(3):703-7. PubMed ID: 1899824
[TBL] [Abstract][Full Text] [Related]
11. Noninvasive cardiac output determined with a new method based on gas exchange measurements and carbon dioxide rebreathing: a study in animals/pigs.
Gedeon A; Krill P; Kristensen J; Gottlieb I
J Clin Monit; 1992 Oct; 8(4):267-78. PubMed ID: 1453186
[TBL] [Abstract][Full Text] [Related]
12. Energy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry.
Brandi LS; Grana M; Mazzanti T; Giunta F; Natali A; Ferrannini E
Crit Care Med; 1992 Sep; 20(9):1273-83. PubMed ID: 1521442
[TBL] [Abstract][Full Text] [Related]
13. The effects of shivering on oxygen consumption and carbon dioxide production in patients rewarming from hypothermic cardiopulmonary bypass.
Ralley FE; Wynands JE; Ramsay JG; Carli F; MacSullivan R
Can J Anaesth; 1988 Jul; 35(4):332-7. PubMed ID: 3135952
[TBL] [Abstract][Full Text] [Related]
14. [Relationship between mixed venous saturation and cardiac index, hemoglobin and oxygen consumption in aortic surgery].
Pestaña D; García de Lorenzo A; Madero R
Rev Esp Anestesiol Reanim; 1998 Apr; 45(4):136-40. PubMed ID: 9646653
[TBL] [Abstract][Full Text] [Related]
15. Monitoring of pacemaker induced changes in cardiac output with inspired to endtidal oxygen difference in paediatric cardiac surgery patients.
Bengtsson J; Edberg KE; Nilsson B; Bengtson JP
Paediatr Anaesth; 2001 Mar; 11(2):191-7. PubMed ID: 11240878
[TBL] [Abstract][Full Text] [Related]
16. Changes in tissue oxygen tension, venous saturation, and Fick-based assessments of cardiac output during hyperoxia.
Perry DA; Thomson LM; Pigula FA; Polizzotti BD; DiNardo JA; Nedder A; Gauvreau K; Kheir JN
Acta Anaesthesiol Scand; 2019 Jan; 63(1):93-100. PubMed ID: 30109703
[TBL] [Abstract][Full Text] [Related]
17. Relation between oxygen consumption and oxygen delivery in patients after cardiac surgery.
Routsi C; Vincent JL; Bakker J; De Backer D; Lejeune P; d'Hollander A; Le Clerc JL; Kahn RJ
Anesth Analg; 1993 Dec; 77(6):1104-10. PubMed ID: 8250298
[TBL] [Abstract][Full Text] [Related]
18. Oxygen uptake and mixed venous oxygen saturation during aortic surgery and the first three postoperative hours.
Viale JP; Annat GJ; Ravat FM; Pommier CM; Brudon JR; Desuzinges CJ; Bertrand OM; Motin JP
Anesth Analg; 1991 Nov; 73(5):530-5. PubMed ID: 1952131
[TBL] [Abstract][Full Text] [Related]
19. Oxygen consumption monitoring by oxygen saturation measurements in mechanically ventilated premature neonates.
Shiao SY
J Perinat Neonatal Nurs; 2006; 20(2):178-89. PubMed ID: 16714919
[TBL] [Abstract][Full Text] [Related]
20. Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation.
Lynch J; Kaemmerer H
Intensive Care Med; 1990; 16(4):248-51. PubMed ID: 2358558
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]