These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
392 related articles for article (PubMed ID: 8409061)
1. Importance of electrode design, lead configuration and impedance for successful low energy transcatheter atrial defibrillation in dogs. Kalman JM; Power JM; Chen JM; Farish SJ; Tonkin AM J Am Coll Cardiol; 1993 Oct; 22(4):1199-206. PubMed ID: 8409061 [TBL] [Abstract][Full Text] [Related]
2. Low energy endocardial cardioversion of atrial arrhythmias in humans. Kalman JM; Jones EF; Doolan L; Oliver LE; Power JM; Tonkin AM Pacing Clin Electrophysiol; 1995 Oct; 18(10):1869-75. PubMed ID: 8539154 [TBL] [Abstract][Full Text] [Related]
3. Internal cardioversion of atrial fibrillation in sheep. Cooper RA; Alferness CA; Smith WM; Ideker RE Circulation; 1993 May; 87(5):1673-86. PubMed ID: 8491023 [TBL] [Abstract][Full Text] [Related]
4. Ventricular and atrial defibrillation using new transvenous tripolar and bipolar leads with 5 French electrodes and 8 French subcutaneous catheters. Scott S; Accorti P; Callaghan F; Abels D; Boveja B Pacing Clin Electrophysiol; 1991 Nov; 14(11 Pt 2):1893-8. PubMed ID: 1721195 [TBL] [Abstract][Full Text] [Related]
5. Endocardial pacing, cardioversion and defibrillation using a braided endocardial lead system. Saksena S; Luceri R; Krol RB; Brownstein S; Burkhardt E; Accorti P; Brewer G; Scott S; Callaghan F; Livingston A Am J Cardiol; 1993 Apr; 71(10):834-41. PubMed ID: 8456763 [TBL] [Abstract][Full Text] [Related]
6. Optimization of shocking lead configuration for transvenous atrial defibrillation. Krum D; Hare J; Mughal K; Jazayeri MR; Deshpande S; Dhala A; Blanck Z; Akhtar M; Sra J J Cardiovasc Electrophysiol; 1998 Sep; 9(9):998-1003. PubMed ID: 9786081 [TBL] [Abstract][Full Text] [Related]
7. Atrial defibrillation using temporary epicardial defibrillation stainless steel wire electrodes: studies in the canine sterile pericarditis model. Ortiz J; Sokoloski MC; Ayers GM; Cmolik BL; Niwano S; Geha AS; Waldo AL J Am Coll Cardiol; 1995 Nov; 26(5):1356-64. PubMed ID: 7594054 [TBL] [Abstract][Full Text] [Related]
8. Efficacy and safety of monophasic and biphasic waveform shocks using a braided endocardial defibrillation lead system. Saksena S; Scott SE; Accorti PR; Boveja BK; Abels D; Callaghan FJ Am Heart J; 1990 Dec; 120(6 Pt 1):1342-7. PubMed ID: 2248181 [TBL] [Abstract][Full Text] [Related]
9. Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system. Usui M; Walcott GP; Strickberger SA; Rollins DL; Smith WM; Ideker RE Pacing Clin Electrophysiol; 1996 Jan; 19(1):65-71. PubMed ID: 8848379 [TBL] [Abstract][Full Text] [Related]
10. Transseptal defibrillation is superior for transvenous defibrillation. Singer I; Goldsmith J; Maldonado C Pacing Clin Electrophysiol; 1995 Jan; 18(1 Pt 2):229-32. PubMed ID: 7724405 [TBL] [Abstract][Full Text] [Related]
11. Low-energy endocardial defibrillation using dual, triple, and quadruple electrode systems. Munsif AN; Saksena S; DeGroot P; Krol RB; Matthew P; Giorgberidze I; Kaushik RR; Mehra R Am J Cardiol; 1997 Jun; 79(12):1632-9. PubMed ID: 9202354 [TBL] [Abstract][Full Text] [Related]
12. Low energy transvenous cardioversion of short duration atrial tachyarrhythmias in humans using a single lead system. Heisel A; Jung J; Fries R; Stopp M; Sen S; Schieffer H; Ozbek C Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 1):65-71. PubMed ID: 9121973 [TBL] [Abstract][Full Text] [Related]
13. Effect of electrode configuration and capacitor size on internal atrial defibrillation threshold using leads currently used for ventricular defibrillation. Neri R; Palermo P; Cesario AS; Baragli D; Amici E; Laudadio MT; De Rosa A; DeSeta F; Mongeon L; Gambelli G J Interv Card Electrophysiol; 1999 Jul; 3(2):149-53. PubMed ID: 10387142 [TBL] [Abstract][Full Text] [Related]
14. Successful atrial defibrillation with very-low-energy shocks by means of temporary epicardial wire electrodes. Cmolik BL; Oritz J; Ayers GM; Lee JH; Geha AS; Waldo AL J Thorac Cardiovasc Surg; 1996 Feb; 111(2):392-7; discussion 397-8. PubMed ID: 8583812 [TBL] [Abstract][Full Text] [Related]
15. Low energy conversion of atrial fibrillation in the sheep. Powell AC; Garan H; McGovern BA; Fallon JT; Krishnan SC; Ruskin JN J Am Coll Cardiol; 1992 Sep; 20(3):707-11. PubMed ID: 1512352 [TBL] [Abstract][Full Text] [Related]
16. Low-energy endocardial defibrillation using an axillary or a pectoral thoracic electrode location. Saksena S; DeGroot P; Krol RB; Raju R; Mathew P; Mehra R Circulation; 1993 Dec; 88(6):2655-60. PubMed ID: 8252676 [TBL] [Abstract][Full Text] [Related]
17. Clinical efficacy of dual electrode systems for endocardial cardioversion of ventricular tachycardia: a prospective randomized crossover trial. Saksena S; An H Am Heart J; 1990 Jan; 119(1):15-22. PubMed ID: 2404386 [TBL] [Abstract][Full Text] [Related]
18. Comparative efficacy of subcutaneous mesh and plate electrodes for nonthoracotomy canine defibrillation. Nogami A; Takahashi A; Nitta J; Aonuma K; Iesaka Y; Hiroe M; Marumo F; Hiraoka M Pacing Clin Electrophysiol; 1991 Sep; 14(9):1402-10. PubMed ID: 1720534 [TBL] [Abstract][Full Text] [Related]
19. Effect of electrode position on outcome of low-energy intracardiac cardioversion of atrial fibrillation. Alt E; Schmitt C; Ammer R; Plewan A; Evans F; Pasquantonio J; Ideker T; Lehmann G; Pütter K; Schömig A Am J Cardiol; 1997 Mar; 79(5):621-5. PubMed ID: 9068520 [TBL] [Abstract][Full Text] [Related]
20. Influence of ventricular fibrillation duration on defibrillation energy in dogs using bidirectional pulse discharges. Echt DS; Barbey JT; Black JN Pacing Clin Electrophysiol; 1988 Sep; 11(9):1315-23. PubMed ID: 2460837 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]