128 related articles for article (PubMed ID: 8409994)
1. Effect of an ultrasonic device on temperatures generated in bone and on bone-cement structure.
Brooks AT; Nelson CL; Stewart CL; Skinner RA; Siems ML
J Arthroplasty; 1993 Aug; 8(4):413-8. PubMed ID: 8409994
[TBL] [Abstract][Full Text] [Related]
2. [Cement removal with ultrasound in revision or total hip prosthesis].
Schwaller CA; Elke R
Orthopade; 2001 May; 30(5):310-6. PubMed ID: 11417239
[TBL] [Abstract][Full Text] [Related]
3. Minimal femoral cortical thickness necessary to prevent perforation by ultrasonic tools in joint revision surgery.
Brooks AT; Nelson CL; Hofmann OE
J Arthroplasty; 1995 Jun; 10(3):359-62. PubMed ID: 7673915
[TBL] [Abstract][Full Text] [Related]
4. Thermal tissue damage caused by ultrasonic cement removal from the humerus.
Goldberg SH; Cohen MS; Young M; Bradnock B
J Bone Joint Surg Am; 2005 Mar; 87(3):583-91. PubMed ID: 15741626
[TBL] [Abstract][Full Text] [Related]
5. Excessive heat generation during cutting of cement in the Robodoc hip-revision procedure.
Nogler M; Krismer M; Haid C; Ogon M; Bach C; Wimmer C
Acta Orthop Scand; 2001 Dec; 72(6):595-9. PubMed ID: 11817874
[TBL] [Abstract][Full Text] [Related]
6. Ultrasonic bone cement removal efficiency in total joint arthroplasty revision: A computer tomographic-based cadaver study.
Roitzsch C; Apolle R; Jan Baldus C; Winzer R; Bellova P; Goronzy J; Hoffmann RT; Troost EGC; May CA; Günther KP; Fedders D; Stiehler M
J Orthop Res; 2023 Jun; 41(6):1365-1375. PubMed ID: 36222474
[TBL] [Abstract][Full Text] [Related]
7. Heat generation during cement removal in revision total hip replacement - a comparison of three methods.
Nogler M; Mayr E
Hip Int; 2010; 20(3):308-13. PubMed ID: 20640991
[TBL] [Abstract][Full Text] [Related]
8. Revision arthroplasty facilitated by ultrasonic tool cement removal. An evaluation of whole bone strength in a canine model.
Callaghan JJ; Elder SH; Stranne SK; Fulghum CF; Seaber AV; Myers BS
J Arthroplasty; 1992 Dec; 7(4):495-500. PubMed ID: 1479368
[TBL] [Abstract][Full Text] [Related]
9. [Ultrasonic technique for removing bone cement in total hip revision arthroplasty].
Blacha J; Kozak J; Bednarek A
Chir Narzadow Ruchu Ortop Pol; 1995; 60(2):107-10. PubMed ID: 7671727
[TBL] [Abstract][Full Text] [Related]
10. Histological findings of the femoral bone after cement removal in hip revision. An experimental study of cadaver femurs with two different cement removal procedures.
Porsch M; Schmidt J
Arch Orthop Trauma Surg; 2003 Jun; 123(5):199-202. PubMed ID: 12743715
[TBL] [Abstract][Full Text] [Related]
11. Revision total hip arthroplasty using ultrasonically driven tools. A clinical evaluation.
Gardiner R; Hozack WJ; Nelson C; Keating EM
J Arthroplasty; 1993 Oct; 8(5):517-21. PubMed ID: 8245997
[TBL] [Abstract][Full Text] [Related]
12. Revision arthroplasty facilitated by ultrasonic tool cement removal. Part II: Histologic analysis of endosteal bone after cement removal.
Caillouette JT; Gorab RS; Klapper RC; Anzel SH
Orthop Rev; 1991 May; 20(5):435-40. PubMed ID: 2067878
[TBL] [Abstract][Full Text] [Related]
13. Revision arthroplasty facilitated by ultrasonic tool cement removal. Part I: In vitro evaluation.
Caillouette JT; Gorab RS; Klapper RC; Anzel SH
Orthop Rev; 1991 Apr; 20(4):353-7. PubMed ID: 2041658
[TBL] [Abstract][Full Text] [Related]
14. [Ultrasonic modelling of bone cement - (reoperation of total hip endoprosthesis) (author's transl)].
Weber U; Nietert M; Jacob E
Z Orthop Ihre Grenzgeb; 1981 Jun; 119(3):234-43. PubMed ID: 7269740
[TBL] [Abstract][Full Text] [Related]
15. Femoral cement extraction in revision total hip arthroplasty--an in vitro study comparing computer-assisted freehand-navigated cement removal to conventional cement extraction.
Mumme T; Friedrich MJ; Rode H; Gravius S; Andereya S; Müller-Rath R; de la Fuente M
Biomed Tech (Berl); 2015 Dec; 60(6):567-75. PubMed ID: 26053005
[TBL] [Abstract][Full Text] [Related]
16. Ultrasonic cement removal in revision arthroplasty.
Goldberg SH; Studders EM; Cohen MS
Orthopedics; 2007 Aug; 30(8):632-5. PubMed ID: 17727019
[TBL] [Abstract][Full Text] [Related]
17. Recementing a femoral component into a stable cement mantle using ultrasonic tools.
McCallum JD; Hozack WJ
Clin Orthop Relat Res; 1995 Oct; (319):232-7. PubMed ID: 7554635
[TBL] [Abstract][Full Text] [Related]
18. [Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution].
Aksu N; Hiz VM; Bilgili MG; Aksu T; Düzgün O
Acta Orthop Traumatol Turc; 2003; 37(5):386-94. PubMed ID: 14963395
[TBL] [Abstract][Full Text] [Related]
19. A-mode ultrasound-based intra-femoral bone cement detection and 3D reconstruction in RTHR.
Heger S; Mumme T; Sellei R; De La Fuente M; Wirtz DC; Radermacher K
Comput Aided Surg; 2007 May; 12(3):168-75. PubMed ID: 17538789
[TBL] [Abstract][Full Text] [Related]
20. Comparison of Ho:YAG laser and coblation for interface tissue removal in minimally invasive hip refixation procedures.
Kraaij G; Malan DF; van der Heide HJ; Dankelman J; Nelissen RG; Valstar ER
Med Eng Phys; 2012 Apr; 34(3):370-7. PubMed ID: 21855390
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]