These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 8413034)

  • 21. Accelerator beam data commissioning equipment and procedures: report of the TG-106 of the Therapy Physics Committee of the AAPM.
    Das IJ; Cheng CW; Watts RJ; Ahnesjö A; Gibbons J; Li XA; Lowenstein J; Mitra RK; Simon WE; Zhu TC;
    Med Phys; 2008 Sep; 35(9):4186-215. PubMed ID: 18841871
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A procedure to determine the radiation isocenter size in a linear accelerator.
    González A; Castro I; Martínez JA
    Med Phys; 2004 Jun; 31(6):1489-93. PubMed ID: 15259652
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Leakage radiation from electron applicators on a medical accelerator.
    Pennington EC; Jani SK; Wen BC
    Med Phys; 1988; 15(5):763-5. PubMed ID: 3141759
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Characteristics of an intraoral cone for electron beam therapy with an 18 MeV linear accelerator.
    Wexler MC; Tobochnik N; Spiegler P; Herman MW
    Int J Radiat Oncol Biol Phys; 1982 Nov; 8(11):2001-4. PubMed ID: 6818198
    [No Abstract]   [Full Text] [Related]  

  • 25. Characteristics of electron beams from a medical microtron.
    George RE; Frost SV; Hartson-Eaton M
    Med Phys; 1986; 13(4):533-8. PubMed ID: 3090411
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The energy and angular characteristics of the applicator scattered component of an electron beam.
    Ebert MA; Hoban PW
    Australas Phys Eng Sci Med; 1996 Sep; 19(3):151-9. PubMed ID: 8936724
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Beam characteristics of a retrofitted double-focused multileaf collimator.
    Das IJ; Desobry GE; McNeeley SW; Cheng EC; Schultheiss TE
    Med Phys; 1998 Sep; 25(9):1676-84. PubMed ID: 9775373
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of a photon and an electron beam of a 6-MV linear accelerator.
    Sharma SC; Modur P; Basavatia R
    Med Phys; 1988; 15(4):525-9. PubMed ID: 3211045
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Influence of cone design on the electron beam characteristics on clinical accelerators.
    Kassaee A; Altschuler MD; Ayyalsomayajula S; Bloch P
    Med Phys; 1994 Nov; 21(11):1671-6. PubMed ID: 7891626
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The peripheral dose outside the applicator in electron beams of Oncor linear accelerator.
    Iktueren B; Bilge H; Karacam S; Atkovar G
    Radiat Prot Dosimetry; 2012 Jun; 150(2):192-7. PubMed ID: 22025738
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Unexpectedly large dose rate dependent output from a linear accelerator.
    Cheng PC; Kubo H
    Med Phys; 1988; 15(5):766-7. PubMed ID: 3141760
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accurate characterization of Monte Carlo calculated electron beams for radiotherapy.
    Ma CM; Faddegon BA; Rogers DW; Mackie TR
    Med Phys; 1997 Mar; 24(3):401-16. PubMed ID: 9089592
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Levels of leakage radiation from electron collimators of a linear accelerator.
    Das KR; Cramb JA; Millar RM; Kenny MB; Patterson WR; Ackerly TL; Perkins AE; Chongkitivitya K
    Med Phys; 1990; 17(6):1058-63. PubMed ID: 2126336
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Characteristics of a scintillator-based daily quality assurance device for radiation oncology beams.
    Das IJ; Gazda MJ; Beddar AS
    Med Phys; 1996 Dec; 23(12):2061-7. PubMed ID: 8994171
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Total skin electron therapy at two energies on a linear accelerator.
    Turner JR; Hugtenburg RP; Wynne CJ
    Australas Phys Eng Sci Med; 1995 Dec; 18(4):208-20. PubMed ID: 8867391
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Multiple scattering theory for total skin electron beam design.
    Antolak JA; Hogstrom KR
    Med Phys; 1998 Jun; 25(6):851-9. PubMed ID: 9650172
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Radiation parameters of 6 to 20 MeV scanning electron beams from the Saturne linear accelerator.
    Pfalzner PM; Clarke HC
    Med Phys; 1982; 9(1):117-20. PubMed ID: 6804766
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Reference dosimetry in clinical high-energy photon beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.
    Saiful Huq M; Andreo P
    Med Phys; 2001 Jan; 28(1):46-54. PubMed ID: 11213922
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
    Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
    Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of electron contamination on in vivo surface dosimetry for high-energy photon beams.
    Sjögren R; Karlsson M
    Med Phys; 1998 Jun; 25(6):916-21. PubMed ID: 9650182
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.