These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 8416217)

  • 1. Determining the specific alpha activity of thick sources using a large-area zinc sulfide detector.
    Phoenix KA; Skrable KW; Chabot GE; French CS; Jo M; Falo GA
    Health Phys; 1993 Jan; 64(1):64-9. PubMed ID: 8416217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Theoretical response of a ZnS(Ag) scintillation detector to alpha-emitting sources and suggested applications.
    Skrable KW; Phoenix KA; Chabot GE; French CS; Jo M; Falo GA
    Health Phys; 1991 Mar; 60(3):381-92. PubMed ID: 1995511
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of the specific alpha activity of thick sources with a large area ZnS(Ag) scintillation detector.
    Djurasević M; Vukanac I; Kandić A; Nadderd L; Milosević Z; Radenković M
    J Environ Radioact; 2007; 95(2-3):75-85. PubMed ID: 17383779
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of an alpha probe detector for in vitro cellular dosimetry.
    Hui TE; James AC; Jostes RF; Schwartz JL; Swinth KL; Cross FT
    Health Phys; 1993 Jun; 64(6):647-52. PubMed ID: 8491621
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of ²³⁹Pu airborne concentration alpha correction factor for a zinc sulfide detector via ambient ²²²Rn progeny air sampling.
    Hale AC; Tries MA
    Health Phys; 2011 Feb; 100(2):201-9. PubMed ID: 21399436
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A short history of ZnS on Mylar as an alpha-scintillation detector.
    Fisenne IM; Keller HW
    Health Phys; 1981 May; 40(5):739-41. PubMed ID: 7021478
    [No Abstract]   [Full Text] [Related]  

  • 7. A method to reproduce alpha-particle spectra measured with semiconductor detectors.
    Timón AF; Vargas MJ; Sánchez AM
    Appl Radiat Isot; 2010; 68(4-5):941-5. PubMed ID: 19900817
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A radiation detector fabricated from silicon photodiode.
    Yamamoto H; Hatakeyama S; Norimura T; Tsuchiya T
    Radioisotopes; 1984 Dec; 33(12):864-6. PubMed ID: 6528065
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calculating the calibration coefficient for radon measurements with the bare LR 115-II track detector.
    Nikezić D; Marković P; Uzarov DB
    Health Phys; 1992 Mar; 62(3):239-44. PubMed ID: 1735644
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficiency estimation for detecting U alpha particles in solid-state nuclear track detectors.
    Uda T; Iba H
    Health Phys; 1985 Sep; 49(3):479-89. PubMed ID: 4030336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Mean thickness measurement of distributed fine particles by using alpha-ray absorption curves (author's transl)].
    Yoshida M; Miyahara H; Watanabe T
    Radioisotopes; 1977 Nov; 26(11):767-73. PubMed ID: 579665
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of a multilayer ionization chamber prototype for fast verification of relative depth ionization curves and spread-out-Bragg-peaks in light ion beam therapy.
    Mirandola A; Magro G; Lavagno M; Mairani A; Molinelli S; Russo S; Mastella E; Vai A; Maestri D; La Rosa V; Ciocca M
    Med Phys; 2018 May; 45(5):2266-2277. PubMed ID: 29537642
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Zinc sulfide nanosheets as a novel solid-phase extraction material for flavonoids.
    Wang L; Fan W; Li S; Jia Y; Hou X; Wang X; Wang S; Guo Y
    J Sep Sci; 2017 Mar; 40(6):1403-1409. PubMed ID: 28059481
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-range alpha detector.
    MacArthur DW; Allander KS; Bounds JA; Butterfield KB; McAtee JL
    Health Phys; 1992 Sep; 63(3):324-30. PubMed ID: 1644569
    [TBL] [Abstract][Full Text] [Related]  

  • 15. X-ray absorption fine structure evidence for amorphous zinc sulfide as a major zinc species in suspended matter from the Seine River downstream of Paris, Ile-de-France, France.
    Priadi C; Le Pape P; Morin G; Ayrault S; Maillot F; Juillot F; Hochreutener R; Llorens I; Testemale D; Proux O; Brown GE
    Environ Sci Technol; 2012 Apr; 46(7):3712-20. PubMed ID: 22360369
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On the reduction of error in alpha track detector measurements of indoor 222Rn.
    Dudney CS; Wilson DL; Bertini H; Gammage RB; Otten JA
    Health Phys; 1995 Oct; 69(4):501-7. PubMed ID: 7558840
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Advantages of CaF2 over ZnS in an alpha-particle scintillation detector.
    Sabol B; Schery SD
    Health Phys; 1981 Jul; 41(1):188-91. PubMed ID: 7275598
    [No Abstract]   [Full Text] [Related]  

  • 18. Alpha-ray spectrometry at high temperature by using a compound semiconductor detector.
    Ha JH; Kim HS
    Appl Radiat Isot; 2013 Nov; 81():165-8. PubMed ID: 23647846
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Alpha pulse height distributions with ZnS(Ag) scintillator.
    Gadd MS; Borak TB
    Health Phys; 1995 Mar; 68(3):394-6. PubMed ID: 7860311
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.
    Shikhaliev PM
    Phys Med Biol; 2006 Sep; 51(17):4267-87. PubMed ID: 16912381
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.