These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Modification of a pivot bearing system on a compact centrifugal pump. Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y Artif Organs; 1996 Mar; 20(3):258-63. PubMed ID: 8694697 [TBL] [Abstract][Full Text] [Related]
23. A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head. Hijikata W; Shinshi T; Asama J; Li L; Hoshi H; Takatani S; Shimokohbe A Artif Organs; 2008 Jul; 32(7):531-40. PubMed ID: 18638307 [TBL] [Abstract][Full Text] [Related]
24. Preclinical evaluation of the Kyocera Gyro centrifugal blood pump for cardiopulmonary bypass. Takami Y; Ohara Y; Otsuka G; Nakazawa T; Nosé Y Perfusion; 1997 Sep; 12(5):335-41. PubMed ID: 9300479 [TBL] [Abstract][Full Text] [Related]
25. The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump. Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y Artif Organs; 1996 Mar; 20(3):252-7. PubMed ID: 8694696 [TBL] [Abstract][Full Text] [Related]
26. The pivot wash in two impeller modes for the Baylor/Miwatec centrifugal blood pump. Yamane T; Kodama T; Nishida M; Maruyama O; Yamamoto Y; Shinohara T; Motomura T; Nosé Y Artif Organs; 2006 Jan; 30(1):70-3. PubMed ID: 16409400 [TBL] [Abstract][Full Text] [Related]
27. An improved design of axially driven permanent maglev centrifugal pump with streamlined impeller. Qian KX; Zeng P; Ru WM; Yuan HY J Med Eng Technol; 2007; 31(3):170-4. PubMed ID: 17454404 [TBL] [Abstract][Full Text] [Related]
28. The balance of the impeller-driver magnet affects the antithrombogenicity in the Gyro permanently implantable pump. Ichikawa S; Nishimura I; Mikami M; Nonaka K; Linneweber J; Kawahito S; Motomura T; Ishitoya H; Glueck J; Shinohara T; Nosé Y Artif Organs; 2002 Nov; 26(11):927-30. PubMed ID: 12406145 [TBL] [Abstract][Full Text] [Related]
29. An implantable centrifugal blood pump for long term circulatory support. Yamazaki K; Litwak P; Kormos RL; Mori T; Tagusari O; Antaki JF; Kameneva M; Watach M; Gordon L; Umezu M; Tomioka J; Koyanagi H; Griffith BP ASAIO J; 1997; 43(5):M686-91. PubMed ID: 9360134 [TBL] [Abstract][Full Text] [Related]
30. A new magnetically suspended centrifugal pump: in vitro and preliminary in vivo assessment. Park CH; Nishimura K; Akamatsu T; Tsukiya T; Matsuda K; Ban T Artif Organs; 1996 Feb; 20(2):128-31. PubMed ID: 8712956 [TBL] [Abstract][Full Text] [Related]
34. Flow visualization study to investigate the secondary flow behind the impeller in the Gyro centrifugal pump. Ichikawa S; Nonaka K; Linneweber J; Kawahito S; Motomura M; Nishimura I; Glueck J; Shinohara T; Nosé Y Artif Organs; 2002 Dec; 26(12):1050-2. PubMed ID: 12460388 [TBL] [Abstract][Full Text] [Related]
35. Magnetically suspended rotary blood pump with radial type combined motor-bearing. Masuzawa T; Kita T; Matsuda K; Okada Y Artif Organs; 2000 Jun; 24(6):468-74. PubMed ID: 10886067 [TBL] [Abstract][Full Text] [Related]
36. Flow visualization in a centrifugal blood pump with an eccentric inlet port. Yamane T; Kodama T; Yamamoto Y; Shinohara T; Nosé Y Artif Organs; 2004 Jun; 28(6):564-70. PubMed ID: 15153149 [TBL] [Abstract][Full Text] [Related]
37. Evaluation of floating impeller phenomena in a Gyro centrifugal pump. Nishimura I; Ichikawa S; Mikami M; Ishitoya H; Motomura T; Kawamura M; Linneweber J; Glueck J; Shinohara T; Nosé Y Biomed Mater Eng; 2013; 23(1-2):49-55. PubMed ID: 23442236 [TBL] [Abstract][Full Text] [Related]
38. Improvement of hemolysis in a centrifugal blood pump with hydrodynamic bearings and semi-open impeller. Kosaka R; Yamane T; Maruyama O; Nishida M; Yada T; Saito S; Hirai S Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3982-5. PubMed ID: 18002872 [TBL] [Abstract][Full Text] [Related]
39. Development of the Baylor-Nikkiso centrifugal pump with a purging system for circulatory support. Naito K; Miyazoe Y; Aizawa T; Mizuguchi K; Tasai K; Ohara Y; Orime Y; Glueck J; Takatani S; Noon GP Artif Organs; 1993 Jul; 17(7):614-8. PubMed ID: 8338436 [TBL] [Abstract][Full Text] [Related]
40. Hemolytic effects of surface roughness of a pump housing in a centrifugal blood pump. Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y Artif Organs; 1997 May; 21(5):428-32. PubMed ID: 9129778 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]