These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
82 related articles for article (PubMed ID: 8432159)
1. The effects of ventilator working pressure during pressure support ventilation. Cohen IL; Bilen Z; Krishnamurthy S Chest; 1993 Feb; 103(2):588-92. PubMed ID: 8432159 [TBL] [Abstract][Full Text] [Related]
2. Comparison of inspiratory work of breathing in T-piece breathing, PSV, and pleural pressure support ventilation (PPSV). Takahashi T; Takezawa J; Kimura T; Nishiwaki K; Shimada Y Chest; 1991 Oct; 100(4):1030-4. PubMed ID: 1914553 [TBL] [Abstract][Full Text] [Related]
3. Measurement of respiratory mechanics using the Siemens Servo Ventilator 900C. Sly PD; Bates JH; Milic-Emili J Pediatr Pulmonol; 1987; 3(6):400-5. PubMed ID: 3480499 [TBL] [Abstract][Full Text] [Related]
4. Relationship between work of breathing provided by a ventilator and patients' inspiratory drive during pressure support ventilation; effects of inspiratory rise time. Uchiyama A; Imanaka H; Taenaka N Anaesth Intensive Care; 2001 Aug; 29(4):349-58. PubMed ID: 11512644 [TBL] [Abstract][Full Text] [Related]
5. Pressure-time relationships of pressure-limited neonatal ventilators. Schachter EN; Lehnert BE; Specht W Crit Care Med; 1983 Mar; 11(3):177-81. PubMed ID: 6572584 [TBL] [Abstract][Full Text] [Related]
6. Pressure control ventilation: three anesthesia ventilators compared using an infant lung model. Stayer SA; Bent ST; Skjonsby BS; Frolov A; Andropoulos DB Anesth Analg; 2000 Nov; 91(5):1145-50. PubMed ID: 11049900 [TBL] [Abstract][Full Text] [Related]
7. Estimation of triggering work of breathing. The dependence on lung mechanics and bias flow during pressure support ventilation. Konyukov Y; Takahashi T; Kuwayama N; Hotta T; Takezawa J; Shimada Y Chest; 1994 Jun; 105(6):1836-41. PubMed ID: 8205885 [TBL] [Abstract][Full Text] [Related]
8. Simulation of late inspiratory rise in airway pressure during pressure support ventilation. Yu CH; Su PL; Lin WC; Lin SH; Chen CW Respir Care; 2015 Feb; 60(2):201-9. PubMed ID: 25371401 [TBL] [Abstract][Full Text] [Related]
9. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
10. [Analysis by computer simulation of double breathing during pressure support ventilation]. Ohtsuka M; Usuda Y; Yamaguchi O; Yamada Y Masui; 2004 Dec; 53(12):1369-76. PubMed ID: 15682797 [TBL] [Abstract][Full Text] [Related]
11. Tracheal gas insufflation-pressure control versus volume control ventilation. A lung model study. Imanaka H; Kacmarek RM; Ritz R; Hess D Am J Respir Crit Care Med; 1996 Mar; 153(3):1019-24. PubMed ID: 8630540 [TBL] [Abstract][Full Text] [Related]
12. Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing. Messinger G; Banner MJ; Blanch PB; Layon AJ Chest; 1995 Aug; 108(2):509-14. PubMed ID: 7634891 [TBL] [Abstract][Full Text] [Related]
13. Using conventional infant ventilators at unconventional rates. Boros SJ; Bing DR; Mammel MC; Hagen E; Gordon MJ Pediatrics; 1984 Oct; 74(4):487-92. PubMed ID: 6384912 [TBL] [Abstract][Full Text] [Related]
14. Respiratory muscle pressure analysis in pressure-support ventilation. Yamada Y; Shigeta M; Suwa K; Hanaoka K J Appl Physiol (1985); 1994 Nov; 77(5):2237-43. PubMed ID: 7868440 [TBL] [Abstract][Full Text] [Related]
15. Inspiratory capacity at inflation hold in ventilated newborns: a surrogate measure for static compliance of the respiratory system. Hentschel R; Semar N; Guttmann J Pediatr Crit Care Med; 2012 Sep; 13(5):560-7. PubMed ID: 22460774 [TBL] [Abstract][Full Text] [Related]
16. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing. Aerts JG; van den Berg B; Bogaard JM Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760 [TBL] [Abstract][Full Text] [Related]
17. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning. Patel RG; Petrini MF Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020 [TBL] [Abstract][Full Text] [Related]
18. Inspiratory oscillatory flow with a portable ventilator: a bench study. Frank GE; Trimmel H; Fitzgerald RD Crit Care; 2005 Aug; 9(4):R315-22. PubMed ID: 16137343 [TBL] [Abstract][Full Text] [Related]
19. The effect of mechanical ventilator settings during ventilator hyperinflation techniques: a bench-top analysis. Thomas PJ Anaesth Intensive Care; 2015 Jan; 43(1):81-7. PubMed ID: 25579293 [TBL] [Abstract][Full Text] [Related]
20. In vitro evaluation of aerosol bronchodilator delivery during mechanical ventilation: pressure-control vs. volume control ventilation. Hess DR; Dillman C; Kacmarek RM Intensive Care Med; 2003 Jul; 29(7):1145-50. PubMed ID: 12750882 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]