These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 8432265)

  • 1. Vibrotactile threshold testing in occupational health: a review of current issues and limitations.
    Gerr F; Letz R
    Environ Res; 1993 Jan; 60(1):145-59. PubMed ID: 8432265
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of vibrotactile thresholds with physical examination and electrophysiological assessment.
    Gerr F; Letz R; Hershman D; Farraye J; Simpson D
    Muscle Nerve; 1991 Nov; 14(11):1059-66. PubMed ID: 1745278
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Progress in vibrotactile threshold evaluation techniques: a review.
    Gandhi MS; Sesek R; Tuckett R; Bamberg SJ
    J Hand Ther; 2011; 24(3):240-55; quiz 256. PubMed ID: 21439781
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technology literature review: quantitative sensory testing.
    Chong PS; Cros DP
    Muscle Nerve; 2004 May; 29(5):734-47. PubMed ID: 15116380
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of perception threshold testing and thermal-vibratory testing.
    Lowenstein L; Jesse K; Kenton K
    Muscle Nerve; 2008 Apr; 37(4):514-7. PubMed ID: 18067137
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of current perception threshold testing and thermal-vibratory testing.
    Katims JJ
    Muscle Nerve; 2009 Feb; 39(2):273; author reply 273-4. PubMed ID: 19145646
    [No Abstract]   [Full Text] [Related]  

  • 7. Psychophysical testing in human populations exposed to neurotoxicants.
    Maurissen JP
    Neurobehav Toxicol Teratol; 1985; 7(4):309-17. PubMed ID: 2997637
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Nerve conduction studies and current perception thresholds in workers assessed for hand-arm vibration syndrome.
    Lander L; Lou W; House R
    Occup Med (Lond); 2007 Jun; 57(4):284-9. PubMed ID: 17429102
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reproducibility of different methods for diagnosing and monitoring diabetic neuropathy.
    Nasseri K; Strijers RL; Dekhuijzen LS; Buster M; Bertelsmann FW
    Electromyogr Clin Neurophysiol; 1998; 38(5):295-9. PubMed ID: 9741007
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The use of PSSD testing in comparison to vibrotactile testing of vibration exposed workers.
    Jetzer T; Dellon LA; Mitterhauser MD
    Cent Eur J Public Health; 1995; 3 Suppl():49-51. PubMed ID: 9150969
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Vibrotactile threshold for hairy skin and its transformation into equivalent bone-conduction loss for the mastoid.
    Lamoré PJ
    Audiology; 1984; 23(6):537-51. PubMed ID: 6517747
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Vibrotactile perception and effects of short-term exposure to hand-arm vibration.
    Burström L; Lundström R; Hagberg M; Nilsson T
    Ann Occup Hyg; 2009 Jul; 53(5):539-47. PubMed ID: 19403839
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The vibrotactile threshold (VT) at the fingertips of chain saw operators.
    Ahrend KD; Hartung E; Dupuis H
    Cent Eur J Public Health; 1995; 3 Suppl():85-7. PubMed ID: 9150979
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative measurement of vibratory perception threshold using a new vibrometer TM-31A.
    Kamon N
    J Occup Med; 1994 Sep; 36(9):989-96. PubMed ID: 7823221
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Epidemiological case definitions of peripheral neuropathy: experience from two neurotoxicity studies.
    Gerr F; Letz R
    Neurotoxicology; 2000 Oct; 21(5):761-8. PubMed ID: 11130280
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Comparison of vibrotactile thresholds in women obtained with two psychophysical measurement methods].
    Harazin B; Kuprowski J; Harazin-Lechowska A
    Med Pr; 2004; 55(4):321-8. PubMed ID: 15620041
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of health outcomes following tendon and nerve repair.
    MacDermid JC
    J Hand Ther; 2005; 18(2):297-312. PubMed ID: 15891987
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vibrotactile sense and mechanical functional state of the arm and hand among computer users compared with a control group.
    Jensen BR; Pilegaard M; Momsen A
    Int Arch Occup Environ Health; 2002 Jun; 75(5):332-40. PubMed ID: 11981672
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vibrotactile detection thresholds for chest skin of amputees following targeted reinnervation surgery.
    Schultz AE; Marasco PD; Kuiken TA
    Brain Res; 2009 Jan; 1251():121-9. PubMed ID: 19059226
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sensory thresholds among construction trade painters: a cross-sectional study using new methods for measuring temperature and vibration sensitivity.
    Bove FJ; Letz R; Baker EL
    J Occup Med; 1989 Apr; 31(4):320-5. PubMed ID: 2785589
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.