These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 8432648)

  • 1. Radium needle used to calibrate germanium gamma-ray detector.
    Kamboj S; Lovett D; Kahn B; Walker D
    Health Phys; 1993 Mar; 64(3):300-5. PubMed ID: 8432648
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An evaluation of germanium detectors employed for the measurement of radionuclides deposited in lungs using an experimental and Monte Carlo approach.
    Webb JL; Kramer GH
    Health Phys; 2001 Dec; 81(6):711-9. PubMed ID: 11725891
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precise efficiency calibration of an HPGe detector up to 3.5 MeV, with measurements and Monte Carlo calculations.
    Helmer RG; Nica N; Hardy JC; Iacob VE
    Appl Radiat Isot; 2004; 60(2-4):173-7. PubMed ID: 14987638
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Monte Carlo simulation of photon counting efficiency for germanium detectors.
    Kamboj S; Kahn B
    Health Phys; 1996 Apr; 70(4):512-9. PubMed ID: 8617591
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The determination of the efficiency of a Compton suppressed HPGe detector using Monte Carlo simulations.
    McNamara AL; Heijnis H; Fierro D; Reinhard MI
    J Environ Radioact; 2012 Apr; 106():1-7. PubMed ID: 22304994
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Non-destructive determination of 224Ra, 226Ra and 228Ra concentrations in drinking water by gamma spectroscopy.
    Parekh P; Haines D; Bari A; Torres M
    Health Phys; 2003 Nov; 85(5):613-20. PubMed ID: 14571995
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Angular insensitivity of a gamma spectrometer for in-field applications.
    Toivonen H; Dowdall M
    Appl Radiat Isot; 2023 Jan; 191():110561. PubMed ID: 36379132
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of HPGe detector response using MCNP5 for 20-150 keV X-rays.
    Salgado CM; Conti CC; Becker PH
    Appl Radiat Isot; 2006 Jun; 64(6):700-5. PubMed ID: 16427294
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficiency transfer in the calibration of a coaxial p-type HpGe detector using the Monte Carlo method.
    Vargas MJ; Díaz NC; Sánchez DP
    Appl Radiat Isot; 2003 Jun; 58(6):707-12. PubMed ID: 12798381
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A hybrid method to determine efficiency curve of HPGe detectors.
    Ozben CS; Emirhan EM
    Appl Radiat Isot; 2009 Jun; 67(6):1110-3. PubMed ID: 19297177
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Scintillation gamma spectrometer for analysis of hydraulic fracturing waste products.
    Ying L; O'Connor F; Stolz JF
    J Environ Sci Health A Tox Hazard Subst Environ Eng; 2015; 50(5):511-5. PubMed ID: 25734826
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of 7Be concentration in outdoor ambient air.
    Khan S; Alaamer AS; Tahir SN
    Health Phys; 2008 Oct; 95(4):433-5. PubMed ID: 18784516
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibration of an in-situ BEGe detector using semi-empirical and Monte Carlo techniques.
    Agrafiotis K; Karfopoulos KL; Anagnostakis MJ
    Appl Radiat Isot; 2011 Aug; 69(8):1151-5. PubMed ID: 21193317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector.
    Cebastien Joel GS; Maurice NM; Eric Jilbert NM; Ousmanou M; David S
    J Environ Radioact; 2018 Sep; 189():109-119. PubMed ID: 29653355
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of energy responses of germanium detectors and correction of measured spectra by means of Monte Carlo simulation.
    Chan HP; Chen CT; Doi K; Fewell TR; Shuping RE
    Radiat Res; 1984 Sep; 99(3):443-64. PubMed ID: 6473707
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement techniques for radium and the actinides in man at the Center for Human Radiobiology.
    Toohey RE; Keane AT; Rundo J
    Health Phys; 1983; 44 Suppl 1():323-41. PubMed ID: 6305878
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo based method for conversion of in-situ gamma ray spectra obtained with a portable Ge detector to an incident photon flux energy distribution.
    Clouvas A; Xanthos S; Antonopoulos-Domis M; Silva J
    Health Phys; 1998 Feb; 74(2):216-30. PubMed ID: 9450590
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simple methodology for characterization of germanium coaxial detectors by using Monte Carlo simulation and evolutionary algorithms.
    Guerra JG; Rubiano JG; Winter G; Guerra AG; Alonso H; Arnedo MA; Tejera A; Gil JM; Rodríguez R; Martel P; Bolivar JP
    J Environ Radioact; 2015 Nov; 149():8-18. PubMed ID: 26188622
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental and MC determination of HPGe detector efficiency in the 40-2754 keV energy range for measuring point source geometry with the source-to-detector distance of 25 cm.
    Dryak P; Kovar P
    Appl Radiat Isot; 2006; 64(10-11):1346-9. PubMed ID: 16564693
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a traceable calibration methodology for solid (68)Ge/(68)Ga sources used as a calibration surrogate for (18)F in radionuclide activity calibrators.
    Zimmerman BE; Cessna JT
    J Nucl Med; 2010 Mar; 51(3):448-53. PubMed ID: 20197450
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.